{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5527-3HA06","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5527-3HA06","canonicalUrl":"https://aoctrl.com/siemens/3RW5527-3HA06","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5527-3HA06","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RW5527-3HA06 SIRIUS soft starter, ATEX/IECEx certified, 200-690 V, trip class 10A/10E/20E/30E, PROFIBUS, Modbus RTU/TCP, EtherNet/IP, 306 x 185 x 203 mm.","salesMarkdown":"## Hazardous-area motor starting with ATEX certification The 3RW5527-3HA06 is a SIRIUS soft starter carrying both ATEX and IECEx certification, making it a candidate for motor starting in Zone 1/21 or Zone 2/22 classified areas — think pump houses on chemical lines or conveyor drives in grain handling where the arc from a contactor closing could ignite the atmosphere. Rated for 200-690 V supply, it handles global line voltages from 208 V North American systems up to 690 V European industrial without a transformer tap change. ## Trip class flexibility and starting profiles Offers selectable trip classes 10A, 10E (default), 20E, and 30E per IEC 60947-4-2 — a 10A class kicks out in 10 seconds at 7× FLA for light-start loads like centrifugal pumps, while 30E buys 30 seconds for high-inertia loads such as centrifuges or crushers. The built-in voltage ramp, torque control, and breakaway pulse let you tune the start profile for a specific machine — a breakaway pulse can crack a stuck conveyor belt loose before the ramp takes over, reducing mechanical shock on the gearbox. Pump ramp down and DC braking are standard, so the same unit handles both soft stop for water hammer prevention and fast stop for a centrifuge that needs to park in position. ## Fieldbus integration and analog feedback Native support for PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP means it drops onto most plant networks without a gateway — the controls integrator assigns the IP and maps the start/stop and status words into the PLC I/O tree. The analog output delivers 4-20 mA or 0-10 V proportional to motor current or torque, feeding a DCS or chart recorder for real-time load monitoring — useful on a mill where the roll torque tells you the strip tension is holding. PROFIenergy support (with the PROFINET communication module) allows the soft starter to coordinate energy-saving shutdowns during production pauses — a feature that matters when the line cycles between batches and the motor stays idle for minutes at a time. ## Ambient temperature derating and panel layout Operates from -25 to +60 °C ambient, but Siemens requires derating above 40 °C — in a steel mill enclosure near the furnace, expect to reduce the continuous rating or add forced ventilation to stay within the thermal budget. Dimensions are 306 mm high, 185 mm wide, 203 mm deep — it needs 100 mm clearance above, 75 mm below, 10 mm forward, and 0 mm backward, so it fits a standard 600 mm deep enclosure with room for the main cables on top. Side clearance is only 5 mm to adjacent devices, which lets you pack multiple soft starters side-by-side in a multi-motor control centre without wasting panel width. ## Lifecycle and compliance documentation Carries CE, UL, and CSA approvals, covering installations in the EU, North America, and Canada without separate certification paperwork for each region. Accuracy Class 5 per IEC 61557-12 applies to the integrated metering — the current and voltage measurements are within 5 % of reading, adequate for energy monitoring but not for billing-grade submetering.","metaTitle":"Siemens 3RW5527-3HA06 Soft Starter, 200-690 V, ATEX, Active","metaDescription":"Siemens 3RW5527-3HA06 soft starter, 200-690 V, ATEX/IECEx certified, trip class 10A-30E, active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"ATEX":"Yes","Depth":"203 mm","IECEx":"Yes","Width":"185 mm","title":"3RW5527-3HA06","Height":"306 mm","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","Backwards":"0 mm","Downwards":"75 mm","CE marking":"Yes","DC braking":"Yes","Event List":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Trip Class":"CLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard and PROFINET High-Feature communication modules","Rated Value":"200 ... 690 V","UL approval":"Yes","description":"SIRIUS soft starter 200-690 V 93 A, 24 V AC/DC spring-type terminals","CSA approval":"Yes","Remote Reset":"Yes","Voltage Ramp":"Yes","Analog Output":"Yes; 4 ... 20 mA (default) / 0 ... 10 V","Error Logbook":"Yes","Motor Heating":"Yes","Accuracy Class":"5 (based on IEC 61557-12)","Pump Ramp Down":"Yes","Screw Terminal":"No","Service Factor":"1.15","Torque Control":"Yes","Trace Function":"Yes","Breakaway Pulse":"Yes","Firmware Update":"Yes","Parameterizable":"4","lifecycle_stage":"current","Combined Braking":"Yes","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"Yes","Minimum Load [%]":"10 %; Relative to set Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 6 g / 11 ms with potential contact lifting","Start Torque [%]":"10 ... 100 %","Mounting Position":"Vertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)","PROFINET standard":"Yes","at DC rated value":"24 V","Product Brand Name":"SIRIUS","Application Wizards":"Yes","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"spring-loaded terminals","Product Designation":"Soft starter","Reversing Operation":"Yes","Stopping Torque [%]":"10 ... 100 %","Alternative Run-Down":"Yes","Condition Monitoring":"Yes","Idle Time Adjustable":"0 ... 255 s","Inside-Delta Circuit":"Yes; Only up to 600 V operating voltage","Starting Voltage [%]":"20 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm up to 6 Hz; 2 g up to 500 Hz","at 50 Hz rated value":"24 V","at 60 Hz rated value":"24 V","PROFINET high-feature":"Yes","Ramp-Down (Soft Stop)":"Yes","Torque Limitation [%]":"20 ... 200 %","at 40 °C rated value":"161 A","at 50 °C rated value":"143 A","at 60 °C rated value":"131 A","Communication Function":"Yes","Digital Output Version":"3 normally-open contacts (NO) / 1 changeover contact (CO)","Slave Pointer Function":"Yes","Spring-Loaded Terminal":"Yes","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"28 W","at 50 °C after startup":"25 W","at 60 °C after startup":"23 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","Emergency Operation Mode":"Yes","For Main Current Circuit":"box terminal","Number Of Analog Outputs":"1","Number Of Digital Inputs":"4","Number Of Parameter Sets":"3","Weight Without Packaging":"7.15 kg","at 40 °C during startup":"1 258 W","at 50 °C during startup":"1 065 W","at 60 °C during startup":"948 W","Breakaway Time Adjustable":"0 ... 2 s","For Control Circuit Solid":"2x (0.25 ... 1.5 mm²)","Motor Overload Protection":"Yes; Full motor protection (thermistor motor protection and electronic motor overload protection)","Number Of Digital Outputs":"4","Via Software Configurable":"Yes","Automatic Parameterisation":"Yes","Impulse Voltage Rated Value":"8 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"3","During Storage And Transport":"-40 ... +80 °C","Type Of The Motor Protection":"Electronic, tripping in the event of thermal overload of the motor","Via Software Parameterizable":"Yes","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Electromagnetic Compatibility":"acc. to IEC 60947-4-2","Substance Prohibitance (Date)":"02/15/2018","at 40 °C rated value minimum":"19 A","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","Insulation Voltage Rated Value":"690 V","Ramp-Down Time Of Soft Starter":"0 ... 360 s","at 230 V at 40 °C rated value":"22 kW","at 400 V at 40 °C rated value":"45 kW","at 500 V at 40 °C rated value":"55 kW","at 690 V at 40 °C rated value":"90 kW","Width Of Connection Bar Maximum":"25 mm","Breakaway Voltage [%] Adjustable":"40 ... 100 %","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"3NA3136-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"690 V; does not apply for thermistor connection","Start-Up Ramp Time Of Soft Starter":"0 ... 360 s","at 200/208 V at 50 °C rated value":"25 hp","at 220/230 V at 50 °C rated value":"30 hp","at 460/480 V at 50 °C rated value":"60 hp","at 575/600 V at 50 °C rated value":"75 hp","of circuit breaker usable at 400 V":"3VA2216-7MN32-0AA0; Type of coordination 1, Iq = 15 kA, CLASS 10","of circuit breaker usable at 500 V":"3VA2216-7MN32-0AA0; Type of coordination 1, Iq = 10 kA, CLASS 10","At Inside-Delta Circuit Rated Value":"200 ... 600 V","Programmable Control Inputs/Outputs":"Yes","at the digital inputs at DC maximum":"1 000 m","of communication module Ethernet/IP":"3RW5980-0CE00","Current Unbalance Limiting Value [%]":"10 ... 60 %","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"8 kV","Current Limiting Value [%] Adjustable":"125 ... 800 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","according to ATEX directive 2014/34/EU":"BVS 18 ATEX F 003 X","at AWG cables for control circuit solid":"2x (24 ... 16)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","Blocking Voltage Of The Thyristor Maximum":"1 800 V","Evaluation Of Thermistor Motor Protection":"Yes; Type A PTC or Klixon / Thermoclick","Number Of Digital Outputs Parameterizable":"3","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","Creep Speed In Both Directions Of Rotation":"Yes","Ground-Fault Monitoring Limiting Value [%]":"10 ... 95 %","Soft Starting At Heavy Starting Conditions":"Yes","For Main Contacts With Screw-Type Terminals":"40 ... 53 lbf·in","Recovery Time After Overload Trip Adjustable":"60 ... 1 800 s","Number Of Digital Outputs Not Parameterizable":"1","Type Of Voltage Of The Control Supply Voltage":"AC/DC","With Conductor Cross-Section = 0.5 Mm2 Maximum":"50 m","With Conductor Cross-Section = 1.5 Mm2 Maximum":"150 m","With Conductor Cross-Section = 2.5 Mm2 Maximum":"250 m","Holding Current In Bypass Operation Rated Value":"870 mA","utilization category according to IEC 60947-4-2":"AC 53a","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"440 mA","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","contact rating of auxiliary contacts according to UL":"R300-B300","of communication module PROFINET high-feature usable":"3RW5950-0CH00","Inrush Current By Closing The Bypass Contacts Maximum":"6.3 A","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"2 000 m; Derating as of 1000 m, see catalog","of the gG fuse usable at inside-delta circuit up to 500 V":"3NA3136-6; Type of coordination 1, Iq = 65 kA","of circuit breaker usable at 400 V at inside-delta circuit":"3VA2220-7MN32-0AA0; Type of coordination 1, Iq = 15 kA, CLASS 10","of circuit breaker usable at 500 V at inside-delta circuit":"3VA2220-7MN32-0AA0; Type of coordination 1, Iq = 10 kA, CLASS 10","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","relative negative tolerance of the control supply voltage at DC":"-20 %","relative positive tolerance of the control supply voltage at DC":"20 %","For Main Contacts For Box Terminal Using Both Clamping Points Solid":"2x (2.5 ... 16 mm²)","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"7.5 A","For Main Contacts For Box Terminal Using Both Clamping Points Stranded":"2x (6 ... 16 mm²), 2x (10 ... 50 mm²)","For Main Contacts For Box Terminal Using The Back Clamping Point Solid":"1x (2.5 ... 16 mm²)","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE3227; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Solid":"1x (2.5 ... 16 mm²)","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"20 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-20 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-20 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"20 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"20 %","For Main Contacts For Box Terminal Using The Back Clamping Point Stranded":"1x (10 ... 70 mm²)","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1224-0; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Stranded":"1x (10 ... 70 mm²)","at AWG cables for control circuit finely stranded with core end processing":"2x (24 ... 16)","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15 %","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10 %","at AWG cables for main contacts for box terminal using the back clamping point":"1x (10 ... 2/0)","For Main Contacts For Box Terminal Using Both Clamping Points Finely Stranded With Core End Processing":"2x (2.5 ... 35 mm²)","For Main Contacts For Box Terminal Using The Back Clamping Point Finely Stranded With Core End Processing":"1x (2.5 ... 50 mm²)","For Main Contacts For Box Terminal Using The Front Clamping Point Finely Stranded With Core End Processing":"1x (2.5 ... 50 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c9da9cded53176eb8927135c39b47e54.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=831184&mlfb=3RW5527-3HA06"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5527-3HA06","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5527-3HA06 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}