{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5535-6HA14","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5535-6HA14","canonicalUrl":"https://aoctrl.com/siemens/3RW5535-6HA14","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5535-6HA14","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW55 soft starter, order code 3RW5535-6HA14, ATEX/IECEx certified, 200-480 V rated voltage, selectable trip classes 10A/10E/20E/30E per IEC 60947-4-2, screw terminals, multi-protocol fieldbus.","salesMarkdown":"## What this soft starter carries The Siemens 3RW5535-6HA14 is a SIRIUS 3RW55 soft starter rated for 200-480 V supply voltage, with selectable trip classes 10A / 10E (default) / 20E / 30E per IEC 60947-4-2. That means you can match the overload protection curve to the motor start profile — CLASS 10A for standard starts, 10E for electronic motor protection, or 20E/30E for high-inertia loads that need a longer ramp. ATEX and IECEx certification (Yes) is the headline here: this unit is approved for use in explosive atmospheres, so it can sit in a Zone 1 or Zone 21 panel feeding a motor in a hazardous area without an external isolation barrier. ## Fieldbus and control options On the communications side, the 3RW5535-6HA14 supports PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP natively — no separate gateway module needed. It also carries PROFIenergy in connection with PROFINET Standard and PROFINET High-Feature communication modules, which lets the drive park the motor during production pauses and save energy on the line. The analog output is configurable as 4-20 mA (default) or 0-10 V, useful for feeding motor current or power data to a PLC or local display. Screw terminals on the power and control side keep wiring straightforward for panel builders. Dimensions are 306 mm height, 185 mm width, 203 mm depth. Clearance requirements: 100 mm upwards, 75 mm downwards, 10 mm forwards, 5 mm at the side, 0 mm backwards. That side clearance is tight — 5 mm means you can stack units nearly side-by-side on the DIN rail without a spacer, but the 100 mm top gap is non-negotiable for heat dissipation from the thyristor stack. The backwards clearance of 0 mm means it can sit flush against the back panel. ## Protection and diagnostics Beyond the trip class, the unit includes DC braking, voltage ramp, pump ramp down, torque control, breakaway pulse, motor heating, and auto-reset with remote reset capability. Accuracy class 5 per IEC 61557-12 means the current measurement is within 5% of reading — adequate for overload protection but not a precision metering device. The service factor of 1.15 allows the motor to run at 115% of its rated load continuously without tripping, common for pump and fan applications. Event list, error logbook, and trace function are built in for fault isolation.","metaTitle":"Siemens 3RW5535-6HA14 Soft Starter, ATEX, 200-480V, Trip Cla","metaDescription":"Siemens 3RW5535-6HA14 soft starter with ATEX/IECEx certification, 200-480V rated voltage, selectable trip classes 10A/10E/20E/30E per IEC 60947-4-2. UL/CSA approved. Sourced to ord","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"ATEX":"Yes","Depth":"203 mm","IECEx":"Yes","Width":"185 mm","title":"3RW5535-6HA14","Height":"306 mm","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","at 50 Hz":"110 ... 250 V","at 60 Hz":"110 ... 250 V","Backwards":"0 mm","Downwards":"75 mm","CE marking":"Yes","DC braking":"Yes","Event List":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Trip Class":"CLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard and PROFINET High-Feature communication modules","Rated Value":"200 ... 480 V","UL approval":"Yes","description":"SIRIUS soft starter 200-480 V 143 A, 110-250 V AC Screw terminals","CSA approval":"Yes","Remote Reset":"Yes","Voltage Ramp":"Yes","Analog Output":"Yes; 4 ... 20 mA (default) / 0 ... 10 V","Error Logbook":"Yes","Motor Heating":"Yes","Accuracy Class":"5 (based on IEC 61557-12)","Pump Ramp Down":"Yes","Screw Terminal":"Yes","Service Factor":"1.15","Torque Control":"Yes","Trace Function":"Yes","Breakaway Pulse":"Yes","Firmware Update":"Yes","Parameterizable":"4","lifecycle_stage":"current","Combined Braking":"Yes","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"Yes","Minimum Load [%]":"10 %; Relative to set Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 6 g / 11 ms with potential contact lifting","Start Torque [%]":"10 ... 100 %","Mounting Position":"Vertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)","PROFINET standard":"Yes","Product Brand Name":"SIRIUS","Application Wizards":"Yes","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"screw-type terminals","Product Designation":"Soft starter","Reversing Operation":"Yes","Stopping Torque [%]":"10 ... 100 %","Alternative Run-Down":"Yes","Condition Monitoring":"Yes","Idle Time Adjustable":"0 ... 255 s","Inside-Delta Circuit":"Yes","Starting Voltage [%]":"20 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm up to 6 Hz; 2 g up to 500 Hz","PROFINET high-feature":"Yes","Ramp-Down (Soft Stop)":"Yes","Torque Limitation [%]":"20 ... 200 %","at 40 °C rated value":"248 A","at 50 °C rated value":"222 A","at 60 °C rated value":"204 A","Communication Function":"Yes","Digital Output Version":"3 normally-open contacts (NO) / 1 changeover contact (CO)","Slave Pointer Function":"Yes","Spring-Loaded Terminal":"No","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"43 W","at 50 °C after startup":"38 W","at 60 °C after startup":"35 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","Emergency Operation Mode":"Yes","For Main Current Circuit":"busbar connection","Number Of Analog Outputs":"1","Number Of Digital Inputs":"4","Number Of Parameter Sets":"3","Weight Without Packaging":"8.5 kg","at 40 °C during startup":"2 115 W","at 50 °C during startup":"1 795 W","at 60 °C during startup":"1 593 W","Breakaway Time Adjustable":"0 ... 2 s","For Control Circuit Solid":"1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)","Motor Overload Protection":"Yes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.","Number Of Digital Outputs":"4","Via Software Configurable":"Yes","Automatic Parameterisation":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"3","During Storage And Transport":"-40 ... +80 °C","Type Of The Motor Protection":"Electronic, tripping in the event of thermal overload of the motor","Via Software Parameterizable":"Yes","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Electromagnetic Compatibility":"acc. to IEC 60947-4-2","Substance Prohibitance (Date)":"02/15/2018","at 40 °C rated value minimum":"29 A","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","Insulation Voltage Rated Value":"480 V","Ramp-Down Time Of Soft Starter":"0 ... 360 s","at 230 V at 40 °C rated value":"37 kW","at 400 V at 40 °C rated value":"75 kW","Width Of Connection Bar Maximum":"25 mm","Breakaway Voltage [%] Adjustable":"40 ... 100 %","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"3NA3244-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"480 V; does not apply for thermistor connection","Start-Up Ramp Time Of Soft Starter":"0 ... 360 s","at 200/208 V at 50 °C rated value":"40 hp","at 220/230 V at 50 °C rated value":"40 hp","at 460/480 V at 50 °C rated value":"100 hp","of circuit breaker usable at 400 V":"3VA2220-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10","At Inside-Delta Circuit Rated Value":"200 ... 480 V","Programmable Control Inputs/Outputs":"Yes","at the digital inputs at DC maximum":"1 000 m","of communication module Ethernet/IP":"3RW5980-0CE00","Current Unbalance Limiting Value [%]":"10 ... 60 %","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","Current Limiting Value [%] Adjustable":"125 ... 800 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","according to ATEX directive 2014/34/EU":"BVS 18 ATEX F 003 X","at AWG cables for control circuit solid":"1x (20 ... 12), 2x (20 ... 14)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","Blocking Voltage Of The Thyristor Maximum":"1 400 V","Evaluation Of Thermistor Motor Protection":"Yes; Type A PTC or Klixon / Thermoclick","Number Of Digital Outputs Parameterizable":"3","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","Creep Speed In Both Directions Of Rotation":"Yes","Ground-Fault Monitoring Limiting Value [%]":"10 ... 95 %","Soft Starting At Heavy Starting Conditions":"Yes","For Main Contacts With Screw-Type Terminals":"89 ... 124 lbf·in","Recovery Time After Overload Trip Adjustable":"60 ... 1 800 s","for DIN cable lug for main contacts stranded":"2x (16 ... 95 mm²)","Number Of Digital Outputs Not Parameterizable":"1","Type Of Voltage Of The Control Supply Voltage":"AC","With Conductor Cross-Section = 0.5 Mm2 Maximum":"50 m","With Conductor Cross-Section = 1.5 Mm2 Maximum":"150 m","With Conductor Cross-Section = 2.5 Mm2 Maximum":"250 m","Holding Current In Bypass Operation Rated Value":"180 mA","utilization category according to IEC 60947-4-2":"AC 53a","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"100 mA","for DIN cable lug for main contacts finely stranded":"2x (25 ... 120 mm²)","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","contact rating of auxiliary contacts according to UL":"R300-B300","of communication module PROFINET high-feature usable":"3RW5950-0CH00","Inrush Current By Closing The Bypass Contacts Maximum":"0.8 A","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"5 000 m; Derating as of 1000 m, see catalog","of the gG fuse usable at inside-delta circuit up to 500 V":"3NA3244-6; Type of coordination 1, Iq = 65 kA","of circuit breaker usable at 400 V at inside-delta circuit":"3VA2325-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"43 A","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE3233; Type of coordination 2, Iq = 65 kA","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"1.6 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-15 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-15 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"10 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"10 %","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1227-0; Type of coordination 2, Iq = 65 kA","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15 %","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10 %"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$4,000.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a9d77821805090b17c247e3a9c74277f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=831225&mlfb=3RW5535-6HA14"},"ai":{"faq":[{"question":"What are the key ratings of 3RW5535-6HA14?","answer":"Rated voltage is 200-480 V. Trip class is selectable: CLASS 10A / 10E (default) / 20E / 30E per IEC 60947-4-2. Service factor 1.15. Accuracy class 5 per IEC 61557-12. Dimensions: 306 x 185 x 203 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5535-6HA14","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5535-6HA14 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}