{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5536-2HF14","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5536-2HF14","canonicalUrl":"https://aoctrl.com/siemens/3RW5536-2HF14","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5536-2HF14","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW5536-2HF14 soft starter, rated 200-480 V, ATEX/IECEx, PROFIBUS, Modbus RTU/TCP, EtherNet/IP, Trip Class 10A/10E/20E/30E.","salesMarkdown":"## Soft starter for motor control in hazardous areas The Siemens 3RW5536-2HF14 is a SIRIUS soft starter rated for 200 to 480 V supply voltage, designed to ramp induction motors up to speed and protect them during start. Its ATEX and IECEx certification means it is approved for installation in explosive atmospheres — a key differentiator for oil/gas, chemical, or grain-handling lines where a standard soft starter would not pass site safety audit. The unit supports multiple trip classes per IEC 60947-4-2: CLASS 10A, 10E (default), 20E, and 30E, so you can match the thermal curve to the load — fast trip for submersible pumps, longer ramp for high-inertia conveyors. ## Fieldbus and control flexibility This soft starter ships with PROFIBUS onboard, plus Modbus RTU, Modbus TCP, and EtherNet/IP — covering the three common industrial Ethernet protocols without an extra option card. A 4-20 mA or 0-10 V analog output feeds motor current or load data back to the PLC for trending or alarming — useful when you are commissioning a line and want to see the start profile on the HMI without a clamp meter. ## Protection and diagnostics for field service Motor heating model, torque control, and a breakaway pulse help start a stuck load. The event list and error logbook store fault history. Accuracy Class 5 per IEC 61557-12 means current measurement within 5% of reading. B10d value of 500,000 gives mechanical endurance for high-cycle applications. Footprint: 185 mm wide, 306 mm tall, 203 mm deep. Clearance requirements are tight: 100 mm upwards, 75 mm downwards, 10 mm forwards, 5 mm at the side, and 0 mm backwards — meaning it can sit flush against a back panel, saving enclosure depth. No screw terminals; the unit uses spring-cage or ring-lug connections typical of the SIRIUS 3RW55 frame. Panel builders should plan for the 100 mm top clearance for cable bending radius and heat dissipation. This 3RW5536-2HF14 is an active catalog item in the Siemens SIRIUS portfolio. No lifecycle-end notice or successor has been issued.","metaTitle":"Siemens 3RW5536-2HF14 Soft Starter, 200-480V, ATEX, PROFIBUS","metaDescription":"Siemens 3RW5536-2HF14 soft starter rated 200-480 V, with ATEX/IECEx, PROFIBUS, Modbus RTU/TCP, EtherNet/IP. Trip Class 10A/10E/20E/30E.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"ATEX":"Yes","Depth":"203 mm","IECEx":"Yes","Width":"185 mm","Height":"306 mm","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","at 50 Hz":"110 ... 250 V","at 60 Hz":"110 ... 250 V","Backwards":"0 mm","Downwards":"75 mm","B10d value":"500 000","CE marking":"Yes","DC braking":"Yes","Event List":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Safe State":"Open load circuit","Trip Class":"CLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard and PROFINET High-Feature communication modules","Rated Value":"200 ... 480 V","UL approval":"Yes","CSA approval":"Yes","Remote Reset":"Yes","Voltage Ramp":"Yes","Analog Output":"Yes; 4 ... 20 mA (default) / 0 ... 10 V","Error Logbook":"Yes","Motor Heating":"Yes","Accuracy Class":"5 (based on IEC 61557-12)","Pump Ramp Down":"Yes","Screw Terminal":"No","Service Factor":"1.15","Torque Control":"Yes","Trace Function":"Yes","With Fail-Safe":"1","Breakaway Pulse":"Yes","Firmware Update":"Yes","Parameterizable":"4","lifecycle_stage":"current","Combined Braking":"Yes","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"Yes","Minimum Load [%]":"10 %; Relative to set Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 6 g / 11 ms with potential contact lifting","Start Torque [%]":"10 ... 100 %","Mounting Position":"Vertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)","PROFINET standard":"Yes","Product Brand Name":"SIRIUS","Application Wizards":"Yes","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"spring-loaded terminals","Product Designation":"Failsafe soft starters","Reversing Operation":"Yes","Stopping Torque [%]":"10 ... 100 %","Alternative Run-Down":"Yes","Condition Monitoring":"Yes","Idle Time Adjustable":"0 ... 255 s","Inside-Delta Circuit":"Yes","Starting Voltage [%]":"20 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm up to 6 Hz; 2 g up to 500 Hz","PROFINET high-feature":"Yes","Ramp-Down (Soft Stop)":"Yes","Torque Limitation [%]":"20 ... 200 %","at 40 °C rated value":"296 A","at 50 °C rated value":"265 A","at 60 °C rated value":"244 A","Communication Function":"Yes","Digital Output Version":"2 normally-open contacts (NO) / 1 normally-closed contact (NC) / 1 changeover contact (CO)","Slave Pointer Function":"Yes","Spring-Loaded Terminal":"Yes","according to IEC 61508":"SIL1","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"51 W","at 50 °C after startup":"46 W","at 60 °C after startup":"42 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","Emergency Operation Mode":"Yes","For Main Current Circuit":"busbar connection","Number Of Analog Outputs":"1","Number Of Digital Inputs":"4","Number Of Parameter Sets":"3","Weight Without Packaging":"9.1 kg","at 40 °C during startup":"2 393 W","at 50 °C during startup":"2 038 W","at 60 °C during startup":"1 814 W","Breakaway Time Adjustable":"0 ... 2 s","For Control Circuit Solid":"2x (0.25 ... 1.5 mm²)","Motor Overload Protection":"Yes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.","Number Of Digital Outputs":"3","Via Software Configurable":"Yes","Automatic Parameterisation":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"3","Safe failure fraction (SFF)":"60 %","During Storage And Transport":"-40 ... +80 °C","Type Of The Motor Protection":"Electronic, tripping in the event of thermal overload of the motor","Via Software Parameterizable":"Yes","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Electromagnetic Compatibility":"acc. to IEC 60947-4-2","Substance Prohibitance (Date)":"11/22/2019","at 40 °C rated value minimum":"34 A","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","Insulation Voltage Rated Value":"480 V","Ramp-Down Time Of Soft Starter":"0 ... 360 s","at 230 V at 40 °C rated value":"45 kW","at 400 V at 40 °C rated value":"90 kW","Width Of Connection Bar Maximum":"25 mm","Breakaway Voltage [%] Adjustable":"40 ... 100 %","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"3NA3365-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"480 V; does not apply for thermistor connection","Start-Up Ramp Time Of Soft Starter":"0 ... 360 s","at 200/208 V at 50 °C rated value":"50 hp","at 220/230 V at 50 °C rated value":"50 hp","at 460/480 V at 50 °C rated value":"100 hp","of circuit breaker usable at 400 V":"3VA2325-7MN32-0AA0; Type of coordination 1, Iq = 30 kA, CLASS 10","of circuit breaker usable at 500 V":"3VA2325-7MN32-0AA0; Type of coordination 1, Iq = 10 kA, CLASS 10","At Inside-Delta Circuit Rated Value":"200 ... 480 V","Programmable Control Inputs/Outputs":"Yes","at the digital inputs at DC maximum":"1 000 m","of communication module Ethernet/IP":"3RW5980-0CE00","Current Unbalance Limiting Value [%]":"10 ... 60 %","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","category according to EN ISO 13849-1":"2","Current Limiting Value [%] Adjustable":"125 ... 800 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","stop category according to EN 60204-1":"0","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","according to ATEX directive 2014/34/EU":"BVS 18 ATEX F 003 X","at AWG cables for control circuit solid":"2x (24 ... 16)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","Number of digital outputs with fail-safe":"1","Blocking Voltage Of The Thyristor Maximum":"1 400 V","Evaluation Of Thermistor Motor Protection":"Yes; Type A PTC or Klixon / Thermoclick","Number Of Digital Outputs Parameterizable":"2","average diagnostic coverage level (DCavg)":"90 %","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","Creep Speed In Both Directions Of Rotation":"Yes","Ground-Fault Monitoring Limiting Value [%]":"10 ... 95 %","Soft Starting At Heavy Starting Conditions":"Yes","For Main Contacts With Screw-Type Terminals":"89 ... 124 lbf·in","safety device type according to IEC 61508-2":"Type B","Recovery Time After Overload Trip Adjustable":"60 ... 1 800 s","for DIN cable lug for main contacts stranded":"2x (16 ... 95 mm²)","Number Of Digital Outputs Not Parameterizable":"1","Type Of Voltage Of The Control Supply Voltage":"AC","With Conductor Cross-Section = 0.5 Mm2 Maximum":"50 m","With Conductor Cross-Section = 1.5 Mm2 Maximum":"150 m","With Conductor Cross-Section = 2.5 Mm2 Maximum":"250 m","Holding Current In Bypass Operation Rated Value":"180 mA","hardware fault tolerance according to IEC 61508":"0","utilization category according to IEC 60947-4-2":"AC 53a","PFHD with high demand rate according to EN 62061":"1E-6 1/h","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","SIL Claim Limit (subsystem) according to EN 62061":"SIL 1","Control Supply Current In Standby Mode Rated Value":"100 mA","PFDavg with low demand rate according to IEC 61508":"0.09","performance level (PL) according to EN ISO 13849-1":"c","for DIN cable lug for main contacts finely stranded":"2x (25 ... 120 mm²)","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","contact rating of auxiliary contacts according to UL":"R300-B300","of communication module PROFINET high-feature usable":"3RW5950-0CH00","Inrush Current By Closing The Bypass Contacts Maximum":"0.8 A","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"2 000 m; Derating as of 1000 m, see catalog","of the gG fuse usable at inside-delta circuit up to 500 V":"3NA3365-6; Type of coordination 1, Iq = 65 kA","of circuit breaker usable at 400 V at inside-delta circuit":"3VA2440-7MN32-0AA0; Type of coordination 1, Iq = 30 kA, CLASS 10","of circuit breaker usable at 500 V at inside-delta circuit":"3VA2440-7MN32-0AA0; Type of coordination 1, Iq = 10 kA, CLASS 10","Diagnostics Test Interval By Internal Test Function Maximum":"1 000 s","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"43 A","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE3334-0B; Type of coordination 2, Iq = 65 kA","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"1.6 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-15 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-15 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"10 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"10 %","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1230-0; Type of coordination 2, Iq = 65 kA","at AWG cables for control circuit finely stranded with core end processing":"2x (24 ... 16)","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15 %","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10 %","OFF-delay time with safety-related request when switched off via control inputs maximum":"100 ms"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=831340&mlfb=3RW5536-2HF14","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RW5536-2HF14/alternatives.json"},"ai":{"faq":[{"question":"Does 3RW5536-2HF14 support PROFIBUS?","answer":"Yes, PROFIBUS is built into this unit. It also supports Modbus RTU, Modbus TCP, and EtherNet/IP."},{"question":"Is 3RW5536-2HF14 suitable for 480V?","answer":"Yes, the rated voltage range is 200 to 480 V, so it is suitable for 480 V systems."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5536-2HF14","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5536-2HF14 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}