{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5545-6HA04","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5545-6HA04","canonicalUrl":"https://aoctrl.com/siemens/3RW5545-6HA04","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5545-6HA04","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RW5545-6HA04 soft starter, 200-480 V, ATEX/IECEx, trip class selectable 10A/10E/20E/30E, screw terminals, 393 x 210 x 203 mm.","salesMarkdown":"## Active production, ATEX-rated, multi-protocol fieldbus The 3RW5545-6HA04: It carries ATEX and IECEx certification for use in explosive atmospheres — that's the headline differentiator versus a standard soft starter. The trip class is field-selectable among 10A, 10E (default), 20E, and 30E per IEC 60947-4-2, giving you the flexibility to match motor starting characteristics from light-duty conveyors to high-inertia loads. Rated supply voltage spans 200…480 V, covering common low-voltage networks worldwide. Screw terminals mean standard panel wiring without crimp tooling changes. ## Fieldbus, analog feedback, and application-specific starting profiles Built-in fieldbus support includes Modbus RTU, Modbus TCP, EtherNet/IP, and PROFIBUS — no separate communication module needed for most networks. The analog output is configurable as 4…20 mA or 0…10 V, feeding motor current or torque feedback to a PLC or DCS. Application-specific features include torque control, a breakaway pulse for high-friction starts, and pump ramp down to eliminate water hammer. Combined braking and DC braking handle rapid stopping without external contactors. The unit also logs events, maintains an error logbook, and supports firmware updates — useful for commissioning diagnostics and future protocol upgrades. ## Mounting, ambient derating, and compliance documentation Physical dimensions are 393 mm high, 210 mm wide, 203 mm deep. Required clearance: 100 mm above, 75 mm below, 10 mm forward, 5 mm to each side, 0 mm backward — plan the enclosure depth and ventilation accordingly. Ambient operating range is -25…+60 °C, with derating required above 40 °C. In a warm panel, that means you need to check the continuous current at the actual ambient — the 40 °C derating point is the thermal design limit for full rating. Approvals include UL, CSA, and CE marking — accepted in North America and the EU. The accuracy class is 5 per IEC 61557-12, and service factor is 1.15.","metaTitle":"Siemens 3RW5545-6HA04 Soft Starter, 200-480 V, ATEX, Active","metaDescription":"Siemens 3RW5545-6HA04 soft starter, 200-480 V, ATEX/IECEx certified, trip class selectable 10A-30E. Active production, sourced per RFQ. UL, CSA, CE.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"ATEX":"Yes","Depth":"203 mm","IECEx":"Yes","Width":"210 mm","title":"3RW5545-6HA04","Height":"393 mm","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","Backwards":"0 mm","Downwards":"75 mm","CE marking":"Yes","DC braking":"Yes","Event List":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Trip Class":"CLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard and PROFINET High-Feature communication modules","Rated Value":"200 ... 480 V","UL approval":"Yes","description":"SIRIUS soft starter 200-480 V 315 A, 24 V AC/DC Screw terminals","CSA approval":"Yes","Remote Reset":"Yes","Voltage Ramp":"Yes","Analog Output":"Yes; 4 ... 20 mA (default) / 0 ... 10 V","Error Logbook":"Yes","Motor Heating":"Yes","Accuracy Class":"5 (based on IEC 61557-12)","Pump Ramp Down":"Yes","Screw Terminal":"Yes","Service Factor":"1.15","Torque Control":"Yes","Trace Function":"Yes","Breakaway Pulse":"Yes","Firmware Update":"Yes","Parameterizable":"4","lifecycle_stage":"current","Combined Braking":"Yes","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"Yes","Minimum Load [%]":"10 %; Relative to set Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 6 g / 11 ms with potential contact lifting","Start Torque [%]":"10 ... 100 %","Mounting Position":"Vertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)","PROFINET standard":"Yes","at DC rated value":"24 V","Product Brand Name":"SIRIUS","Application Wizards":"Yes","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"screw-type terminals","Product Designation":"Soft starter","Reversing Operation":"Yes","Stopping Torque [%]":"10 ... 100 %","Alternative Run-Down":"Yes","Condition Monitoring":"Yes","Idle Time Adjustable":"0 ... 255 s","Inside-Delta Circuit":"Yes","Starting Voltage [%]":"20 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm up to 6 Hz; 2 g up to 500 Hz","at 50 Hz rated value":"24 V","at 60 Hz rated value":"24 V","PROFINET high-feature":"Yes","Ramp-Down (Soft Stop)":"Yes","Torque Limitation [%]":"20 ... 200 %","at 40 °C rated value":"546 A","at 50 °C rated value":"483 A","at 60 °C rated value":"442 A","Communication Function":"Yes","Digital Output Version":"3 normally-open contacts (NO) / 1 changeover contact (CO)","Slave Pointer Function":"Yes","Spring-Loaded Terminal":"No","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"95 W","at 50 °C after startup":"84 W","at 60 °C after startup":"77 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","Emergency Operation Mode":"Yes","For Main Current Circuit":"busbar connection","Number Of Analog Outputs":"1","Number Of Digital Inputs":"4","Number Of Parameter Sets":"3","Weight Without Packaging":"10.2 kg","at 40 °C during startup":"4 966 W","at 50 °C during startup":"4 153 W","at 60 °C during startup":"3 646 W","Breakaway Time Adjustable":"0 ... 2 s","For Control Circuit Solid":"1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)","Motor Overload Protection":"Yes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.","Number Of Digital Outputs":"4","Via Software Configurable":"Yes","Automatic Parameterisation":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"3","During Storage And Transport":"-40 ... +80 °C","Type Of The Motor Protection":"Electronic, tripping in the event of thermal overload of the motor","Via Software Parameterizable":"Yes","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Electromagnetic Compatibility":"acc. to IEC 60947-4-2","Substance Prohibitance (Date)":"02/15/2018","at 40 °C rated value minimum":"63 A","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","Insulation Voltage Rated Value":"480 V","Ramp-Down Time Of Soft Starter":"0 ... 360 s","at 230 V at 40 °C rated value":"90 kW","at 400 V at 40 °C rated value":"160 kW","Width Of Connection Bar Maximum":"45 mm","Breakaway Voltage [%] Adjustable":"40 ... 100 %","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"2x3NA3365-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"480 V; does not apply for thermistor connection","Start-Up Ramp Time Of Soft Starter":"0 ... 360 s","at 200/208 V at 50 °C rated value":"75 hp","at 220/230 V at 50 °C rated value":"100 hp","at 460/480 V at 50 °C rated value":"200 hp","of circuit breaker usable at 400 V":"3VA2440-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V":"3VA2440-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10","At Inside-Delta Circuit Rated Value":"200 ... 480 V","Programmable Control Inputs/Outputs":"Yes","at the digital inputs at DC maximum":"1 000 m","of communication module Ethernet/IP":"3RW5980-0CE00","Current Unbalance Limiting Value [%]":"10 ... 60 %","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","Current Limiting Value [%] Adjustable":"125 ... 800 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","according to ATEX directive 2014/34/EU":"BVS 18 ATEX F 003 X","at AWG cables for control circuit solid":"1x (20 ... 12), 2x (20 ... 14)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","Blocking Voltage Of The Thyristor Maximum":"1 400 V","Evaluation Of Thermistor Motor Protection":"Yes; Type A PTC or Klixon / Thermoclick","Number Of Digital Outputs Parameterizable":"3","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","Creep Speed In Both Directions Of Rotation":"Yes","Ground-Fault Monitoring Limiting Value [%]":"10 ... 95 %","Soft Starting At Heavy Starting Conditions":"Yes","For Main Contacts With Screw-Type Terminals":"124 ... 210 lbf·in","Recovery Time After Overload Trip Adjustable":"60 ... 1 800 s","for DIN cable lug for main contacts stranded":"2x (50 ... 240 mm²)","Number Of Digital Outputs Not Parameterizable":"1","Type Of Voltage Of The Control Supply Voltage":"AC/DC","With Conductor Cross-Section = 0.5 Mm2 Maximum":"50 m","With Conductor Cross-Section = 1.5 Mm2 Maximum":"150 m","With Conductor Cross-Section = 2.5 Mm2 Maximum":"250 m","Holding Current In Bypass Operation Rated Value":"720 mA","utilization category according to IEC 60947-4-2":"AC 53a","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"440 mA","for DIN cable lug for main contacts finely stranded":"2x (70 ... 240 mm²)","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","contact rating of auxiliary contacts according to UL":"R300-B300","of communication module PROFINET high-feature usable":"3RW5950-0CH00","Inrush Current By Closing The Bypass Contacts Maximum":"6.7 A","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"5 000 m; Derating as of 1000 m, see catalog","of the gG fuse usable at inside-delta circuit up to 500 V":"2x3NA3365-6; Type of coordination 1, Iq = 65 kA","of circuit breaker usable at 400 V at inside-delta circuit":"3VA2580-6HN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V at inside-delta circuit":"3VA2580-6HN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)","relative negative tolerance of the control supply voltage at DC":"-20 %","relative positive tolerance of the control supply voltage at DC":"20 %","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"7.5 A","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE3336; Type of coordination 2, Iq = 65 kA","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"20 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-20 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-20 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"20 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"20 %","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1334-2; Type of coordination 2, Iq = 65 kA","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15 %","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10 %"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/09ebd7d1640b0161f0244f41bc10edd6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=831402&mlfb=3RW5545-6HA04"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RW5545-6HA04?","answer":"Submit an RFQ with your target quantity."},{"question":"What approvals does the 3RW5545-6HA04 carry?","answer":"UL, CSA, CE marking, ATEX, and IECEx. That covers North American and EU regulatory acceptance, plus explosive-atmosphere installations."},{"question":"What trip classes are available on this soft starter?","answer":"Selectable trip classes 10A, 10E (default), 20E, and 30E per IEC 60947-4-2. The 10E default suits standard motor starts; 20E and 30E handle higher-inertia loads."},{"question":"What fieldbus protocols does the 3RW5545-6HA04 support?","answer":"Modbus RTU, Modbus TCP, EtherNet/IP, and PROFIBUS. No separate communication module required for these networks."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5545-6HA04","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5545-6HA04 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}