{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3SE6415-1BB02","brand":"Siemens","brandSlug":"siemens","productSlug":"3SE6415-1BB02","canonicalUrl":"https://aoctrl.com/siemens/3SE6415-1BB02","factsUrl":"https://aoctrl.com/api/mcp/products/3SE6415-1BB02","rawCanonicalId":null},"summary":{"shortDescription":"RFID safety switch with tumbler, plastic, quiescent current principle, tumbler monitoring, 24 V DC, with auxiliary release, IP69, locking force 1150 N, individually coded multiple teach-in, coding high according to ISO 14119, diagnostic output, M12 plug 8-pole, 3 LEDs for display of the operating states, 3 directions of actuation, latching force with turnstile adjustable: 25 N or 50 N. hygienic design. actuator 3SE6…","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Limit Switches"],"specifications":{"Note":"when used as door stop: ≥ 50,000 switching cycles (door masses ≤ 5 kg and actuating speed ≤ 0.5 m/s)","Locking Force":"1 500 N","Output Current":"0.5 mA","Safety-Related":"2","Supply Voltage":"26.4 ... 20.4 V","Product Feature":"individually coded, programmable several times, catch 25N/50N","lifecycle_stage":"current","During Operation":"93 %","Fastening Method":"screw fixing","Positive Opening":"No","Product Category":"Non-contact safety switch","Circuit Principle":"spring-actuated lock (closed-circuit principle)","Operating Distance":"2 mm","Product Brand Name":"SIRIUS","Type Of Monitoring":"guard locking","Product Designation":"RFID safety switch with tumbler","Switching Frequency":"0.5 Hz","Width Of The Sensor":"87.5 mm","Wire Length Maximum":"200 m","protection class IP":"IP66 in accordance with EN 60529 IP67 in accordance with EN 60529 IP69 in accordance with EN 60529","Height Of The Sensor":"35 mm","Length Of The Sensor":"120 mm","Overvoltage Category":"Class III","for signal <0> at DC":"-3 ... +5 V","for signal <1> at DC":"15 ... 30 V","of socket 1 at PIN 1":"A1 supply voltage Ub","of socket 1 at PIN 2":"X1 safety input 1","of socket 1 at PIN 3":"A2 GND","of socket 1 at PIN 4":"OSSD1 safety output 1","of socket 1 at PIN 5":"OUT diagnostic output","Design Of The Housing":"special design","Design Of The Product":"rectangular sensor unit","with signal <0> at DC":"-3 ... +5 V","For Signaling Function":"1","Response Delay Maximum":"5 000 ms","according to IEC 61508":"3","Safety-Related Circuits":"Yes","At Digital Input Maximum":"5 ms","At Digital Input Minimum":"40 ms","Locking Mechanism Design":"quiescent current principle","Product Feature Latching":"Yes","Detent Force Adjustable 1":"25 N","Detent Force Adjustable 2":"50 N","Material Of The Enclosure":"plastic, fiberglass reinforced thermoplast, self-extinguishing","Type Of Diagnostic Output":"short-circuit proof, sourcing output","according to EN ISO 14119":"1 150 N","design of the RFID coding":"individual coding, programmable several times","of the bushing 1 at PIN 6":"X2 safety input 2","of the bushing 1 at PIN 7":"OSSD2 safety output 2","of the bushing 1 at PIN 8":"IN magnet controller","Supply Voltage Rated Value":"24 V","NO-Load Current Rated Value":"100 mA","according to EN ISO 13849-1":"4","according to IEC 60068-2-27":"30g / 11 ms","At Diagnostic Output Maximum":"4 V","During Storage And Transport":"-10 ... +90 °C","During Operation Maximum Note":"non-condensing, non-icing","Operating Voltage Rated Value":"24 V","Substance Prohibitance (Date)":"07/01/2006","Type Of Electrical Connection":"M12 plug, 8-pole, A-coded","assured operating distance ON":"1 mm","Insulation Voltage Rated Value":"32 V","assured operating distance OFF":"20 mm","category according to EN 954-1":"4","Operational Current Rated Value":"250 mA","Product Function Status Display":"Yes","At Safety-Related Output Maximum":"4 V","Design Of The Switching Function":"positive switching","Transmission Frequency Rated Value":"125 kHz","Surge Voltage Resistance Rated Value":"0.8 kV","Duration Of Locked-Rotor Current Peak":"200 ms","Type Of Voltage Of The Supply Voltage":"DC","relative ON period [%] of magnet coil":"100 %","At Safety-Related Digital Input Maximum":"1 ms","At Safety-Related Digital Input Minimum":"100 ms","Control Function For Downstream Devices":"No","Cross-Circuit/Short-Circuit Recognition":"Yes","reference code according to IEC 81346-2":"B","At Safety-Related Digital Output Maximum":"1 000 ms","Locked-Rotor Current Peak Of Magnet Coil":"250 mA","display version as status display by LED":"3 LEDs","for guard locking according to IEC 62061":"20 a","Tightening Torque Of Fixing Screw Maximum":"7 N·m","Tightening Torque Of Fixing Screw Minimum":"6 N·m","for guard locking according to ISO 13849-1":"2","Output Current At Diagnostic Output Maximum":"0.05 A","degree of pollution according to EN 60664-1":"3","When Switched Off Via Control Inputs Maximum":"1.5 ms","Current Consumption Of Magnet Coil Rated Value":"100 mA","Product Feature Suitable For Series Connection":"Yes","for position monitoring according to IEC 62061":"20 a","Output Current At Safety-Related Output Maximum":"0.25 A","vibration resistance according to IEC 60068-2-6":"10 ... 150 Hz, amplitude 0.35 mm","For Safety-Related Shutdown Via Actuator Maximum":"100 ms","for position monitoring according to ISO 13849-1":"4","Mechanical Service Life (Operating Cycles) Typical":"1 000 000","Dark Period At Safety-Related Digital Output Maximum":"0.5 ms","Product equipment auxiliary release of guard locking":"Yes","Input Current At Digital Input For Signal <1> Typical":"10 mA","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Design Of The Interface For Safety-Related Communication":"connector M12","Angular Offset Between Guard Locking And Actuator Maximum":"2°","Design Of The Contactless Switching Element Safety-Related":"short-circuit proof, sourcing output","Residual Current At Digital Output With Signal <0> Maximum":"0.5 mA","Design Of The Thread Of The Screw For Securing The Equipment":"2x M6","Fuse Protection Type For External Auxiliary Power Supply Required":"2 A gG","Input Current At Safety-Related Digital Input For Signal <1> Typical":"5 mA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1f26104fc92c6fb060da3c7d931b8ce6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1521463&mlfb=3SE6415-1BB02"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3SE6415-1BB02","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3SE6415-1BB02 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}