{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3SK1112-2BB40","brand":"Siemens","brandSlug":"siemens","productSlug":"3SK1112-2BB40","canonicalUrl":"https://aoctrl.com/siemens/3SK1112-2BB40","factsUrl":"https://aoctrl.com/api/mcp/products/3SK1112-2BB40","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS safety relay, 3SK1112-2BB40, 24 VDC, SIL 3 / PL e, solid-state enabling circuits, 2 instantaneous contacts, spring-loaded terminals, 22.5 x 100 x 91.6 mm.","salesMarkdown":"## Safety relay for guarding applications — SIL 3 / PL e with solid-state enabling circuits The Siemens 3SK1112-2BB40 is a SIRIUS safety relay designed for safety-related circuits in industrial guarding and hazard-zone applications. It achieves SIL 3 per IEC 61508 and PL e per ISO 13849-1, with a safe failure fraction (SFF) of 99 % — meaning it can detect and signal a dangerous fault with very high diagnostic coverage, suitable for safety functions up to the highest performance level. Rated at 24 VDC, the relay uses solid-state enabling circuits rather than electromechanical contacts for the safety path, which eliminates contact wear and bounce in high-cycle applications. The two instantaneous contacts provide the switching output for the safety function. The spring-loaded (push-in) terminals accept solid wire 1x (20…16 AWG) or 2x (20…16 AWG) and stranded with or without ferrules, so the panel builder can land the safety circuit without screwdriver torque checks. ## Integration and wiring — cascading, feedback, and start inputs The relay includes a start input, a feedback input, and a safety switch input, allowing it to be wired into a standard safety chain: E-stop or guard switch on the safety input, feedback from a contactor or motor starter, and a start/reset button on the start input. Cascading design is supported, so multiple 3SK1112-2BB40 units can be linked to expand the number of safety zones without adding a separate safety PLC. The sensor input minimum on-time is 60 ms — short enough for most mechanical safety switches, but long enough to filter contact bounce. Operating frequency is rated at 2 000 1/h maximum, which covers typical machine cycle rates without derating. Electrical connection uses spring-loaded terminals (push-in) — strip length and ferrule sizing per the listed cross-sections: with core end processing 1x (0.5…1.0 mm²) or 2x (0.5…1.0 mm²); without core end processing 1x (0.5…1.5 mm²) or 2x (0.5…1.5 mm²). Shock resistance is 10 g / 11 ms, and mounting position is any. EMC emitted interference meets IEC 60947-5-1, Class A — intended for industrial environments, not residential. Insulation voltage rated value is 50 V.","metaTitle":"Siemens 3SK1112-2BB40 SIRIUS Safety Relay, SIL 3 / PL e, 24","metaDescription":"Siemens 3SK1112-2BB40 SIRIUS safety relay, 24 VDC, SIL 3 / PL e, solid-state enabling circuits, 22.5 mm wide, spring-loaded terminals. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Safety Relays"],"specifications":{"Depth":"91.6 mm","Solid":"1x (20 ... 16), 2x (20 ... 16)","Width":"22.5 mm","at DC":"0.8 ... 1.2","Height":"100 mm","Maximum":"85 ms","Typical":"6 500 ms","Stranded":"1x (20 ... 16), 2x (20 ... 16)","Rated Value":"24 V","Start Input":"Yes","Safety Switch":"Yes","at DC maximum":"85 ms","During Storage":"-40 ... +80 °C","Feedback Input":"Yes","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting","Product Category":"Safety relays","Shock Resistance":"10g / 11 ms","Mounting Position":"any","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"safety relays","Overvoltage Category":"3","Design Of The Product":"Solid-state enabling circuits","Instantaneous Contact":"2","according to IEC 61508":"3","according to IEC 62061":"3","power loss [W] maximum":"2 W","Design Of The Cascading":"yes","Safety-Related Circuits":"Yes","EMC emitted interference":"IEC 60947-5-1, Class A","With Core End Processing":"1x (0.5 ... 1.0 mm²), 2x (0.5 ... 1.0 mm²)","according to ISO 13849-1":"e","Of The Sensor Input Minimum":"60 ms","Operating Frequency Maximum":"2 000 1/h","Safe failure fraction (SFF)":"99 %","Without Core End Processing":"1x (0.5 ... 1.5 mm²), 2x (0.5 ... 1.5 mm²)","Type Of Electrical Connection":"spring-loaded terminal (push-in)","Insulation Voltage Rated Value":"50 V","Monitoring Of Floating Sensors":"Yes","Product Function Parameterizable":"sensor floating / sensor non-floating, monitored start-up / automatic start, 1-channel / 2-channel sensor connection, cross-circuit detection, startup testing","Safety-Related Delayed Switching":"0","Monitoring Of Non-Floating Sensors":"Yes","Relative Humidity During Operation":"10 ... 95 %","air pressure according to SN 31205":"90 ... 106 kPa","of the ON pushbutton input minimum":"0.15 s","Product Feature Cross-Circuit-Proof":"Yes","Cascading Input/Functional Switching":"Yes","Safety-Related Instantaneous Contact":"0","Surge Voltage Resistance Rated Value":"800 V","category according to EN ISO 13849-1":"4","protection class IP of the enclosure":"IP20","stop category according to EN 60204-1":"0","installation environment regarding EMC":"This product is suitable for Class A environments only. In household environments, this device can cause unwanted radio interference. The user is required to implement appropriate measures in this case.","Magnetically Operated Switch Monitoring":"Yes","reference code according to IEC 81346-2":"F","Recovery Time After Power Failure Typical":"6.5 s","Suitability For Interaction Press Control":"No","Touch Protection Against Electrical Shock":"finger-safe","of semiconductor outputs at DC-13 at 24 V":"2 A","safety device type according to IEC 61508-2":"Type B","For Signaling Function Instantaneous Contact":"1","Type Of Electrical Connection Plug-In Socket":"No","Type Of Voltage Of The Control Supply Voltage":"DC","Number Of Sensor Inputs 1-Channel Or 2-Channel":"1","Required Spacing For Grounded Parts At The Side":"5 mm","Type Of The Safety-Related Wiring Of The Inputs":"single-channel and two-channel","hardware fault tolerance according to IEC 61508":"1","vibration resistance according to IEC 60068-2-6":"5 ... 500 Hz: 0.75 mm","PFHD with high demand rate according to EN 62061":"1E-9 1/h","suitability for operation device connector 3ZY12":"No","PFDavg with low demand rate according to IEC 61508":"7E-6","Installation Altitude At Height Above Sea Level Maximum":"4 000 m; Derating, see Product Notification 109792701","Recovery Time After Opening Of The Safety Circuits Typical":"30 ms","Backslide Delay Time After Opening Of The Safety Circuits Typical":"40 ms","design of the fuse link for short-circuit protection of the NO contacts of the relay outputs required":"not required"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/3SK1112-2BB40/alternatives.json"},"ai":{"faq":[{"question":"What safety integrity level does 3SK1112-2BB40 achieve?","answer":"It achieves SIL 3 per IEC 61508, PL e per ISO 13849-1, and SIL 3 per IEC 62061, with a safe failure fraction of 99 %."},{"question":"What is the width and mounting of 3SK1112-2BB40?","answer":"Width is 22.5 mm, height 100 mm, depth 91.6 mm. It mounts via screw and snap-on mounting on a DIN rail in any position."},{"question":"Where can I buy 3SK1112-2BB40?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3SK1112-2BB40","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3SK1112-2BB40 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}