{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3UF7011-1AU00-1-ZI41","brand":"Siemens","brandSlug":"siemens","productSlug":"3UF7011-1AU00-1-ZI41","canonicalUrl":"https://aoctrl.com/siemens/3UF7011-1AU00-1-ZI41","factsUrl":"https://aoctrl.com/api/mcp/products/3UF7011-1AU00-1-ZI41","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMOCODE pro V, control unit 3UF7011-1AU00-1-ZI41, 110-240 V AC/DC supply, 4 digital inputs, relay output, web server, screw and snap-on mounting.","salesMarkdown":"## Control unit for motor management The Siemens 3UF7011-1AU00-1-ZI41 is a SIMOCODE pro V control unit that manages motor feeders in a distributed automation architecture. It takes a rated supply of 110-240 V AC/DC (50/60 Hz) and provides 4 digital inputs, a relay output, and an integrated web server for parameterisation and diagnostics. ## I/O and environmental limits The 4 digital inputs and relay output handle the typical motor feeder signals — start/stop, fault reset, and status feedback. Operating altitude limits apply: full ratings at 2000 m, derated to 3000 m at max +50 °C, and 4000 m at max +40 °C when protective separation is not maintained. Storage and transport range is -40 to +80 °C, with non-condensing humidity from 5 to 95 % during operation. ## Active production and ordering The order code 3UF7011-1AU00-1-ZI41 includes the -ZI41 suffix which specifies the exact variant configuration — confirm the I/O count and supply voltage match your application before committing the BOM line.","metaTitle":"Siemens 3UF7011-1AU00-1-ZI41 SIMOCODE pro V, 110-240 V AC/DC","metaDescription":"Siemens 3UF7011-1AU00-1-ZI41 SIMOCODE pro V motor management system control unit. Rated 110-240 V AC/DC supply, 4 digital inputs, relay output, web server.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLC Communication Modules"],"specifications":{"Top":"40 mm","Left":"0 mm","Depth":"124 mm","Right":"0 mm","Solid":"1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)","Width":"45 mm","title":"3UF7011-1AU00-1-ZI41","Bottom":"40 mm","Height":"111 mm","at 24 V":"2 A","at 60 V":"0.55 A","at 120 V":"6 A","at 125 V":"0.25 A","at 230 V":"3 A","at 240 V":"1 ms","1 Maximum":"2 000 m","2 Maximum":"3 000 m; max. +50 °C (no protective separation)","3 Maximum":"4 000 m; max. +40 °C (no protective separation)","at 50 °C":"6 A","at 60 °C":"5 A","Web Server":"Yes","Rated Value":"110 ... 240 V","description":"basic unit SIMOCODE pro V PN GP Ethernet/PROFINET IO, PN system redundancy, OPC UA server, web server, transfer rate 100 Mbps, 2 x bus connection via RJ45, 4I/3O freely parameterizable, US: 110 - 240 V AC/DC, input for thermistor connection monostable relay outputs, expandable by 1 expansion module(DM, TM, EM) firmware version V3.0.0","Control Unit":"Yes","Direct Start":"Yes","Relay Output":"Yes","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Digital Input":"Yes","Initial Value":"0.85","Shared Device":"No","Slide Control":"No","Test Function":"Yes","Valve Control":"No","During Storage":"-40 ... +80 °C","I&M3 - comment":"Yes","lifecycle_stage":"current","During Operation":"5 ... 95 %","During Transport":"-40 ... +80 °C","Fastening Method":"screw and snap-on mounting","Full-Scale Value":"1.1","Number Of Inputs":"4","Reverse Starting":"Yes","Bus Communication":"Yes","Current Detection":"Yes","Dahlander circuit":"No","Mounting Position":"any","Number Of Outputs":"3","Voltage Detection":"No","according to UKCA":"ITS21UKEX0464","analog I/O module":"No","Star-Delta Circuit":"Yes","Switching Behavior":"monostable","Asymmetry Detection":"Yes","Overload Protection":"Yes","Password Protection":"Yes","at AWG cables solid":"1x (20 ... 12), 2x (20 ... 14)","protection class IP":"IP20","Diagnostics Function":"Yes","Maintenance Function":"Yes","Vibration Resistance":"1-6 Hz / 15 mm; 6-500 Hz / 2 g","at 50 Hz rated value":"110 ... 240 V","at 60 Hz rated value":"110 ... 240 V","Consumed Active Power":"4.5 W","Overvoltage Detection":"No","Transfer Rate Maximum":"100 Mbit/s","Type Of Relay Outputs":"Monostable","according to PROFIBUS":"0","according to PROFINET":"2","Ground Fault Detection":"Yes","Parameterizable Inputs":"Yes","Undervoltage Detection":"No","at AWG cables stranded":"1x (20 ... 14), 2x (20 ... 16)","Active Power Monitoring":"No","Circuit Breaker Control":"Yes","Parameterizable Outputs":"Yes","Phase Failure Detection":"Yes","Power Factor Monitoring":"No","Current Measuring Module":"Yes","I&M2 - installation date":"Yes","according to Ethernet/IP":"0","type 1 acc. to IEC 61131":"Yes","Control Unit With Display":"No","Data Acquisition Function":"Yes","For Thermistor Connection":"1","PROFINET conformity class":"C","protocol is supported NTP":"Yes","Apparent Power Consumption":"8.3 VA","Phase Sequence Recognition":"No","protocol is supported LLDP":"Yes","protocol is supported SNMP":"Yes","Blocking Current Evaluation":"Yes","Dahlander reversing circuit":"No","according to IEC 60068-2-27":"15g / 11 ms","protocol is supported HTTPS":"Yes","Of The Short-Circuit Control":"9 Ω","Pole-Changing Switch Circuit":"No","Star-Delta Reversing Circuit":"No","Type Of Input Characteristic":"Type 1 in accordance with EN 61131-2","fail-safe digital I/O module":"No","Overcurrent Detection 1 Phase":"Yes","Substance Prohibitance (Date)":"08/31/2018","Temperature Monitoring Module":"Yes","supports PROFIenergy shutdown":"Yes","Ground-Fault Monitoring Module":"Yes","Parameterizable Overload Relay":"Yes","Undercurrent Detection 1 Phase":"Yes","Input For Thermistor Connection":"Yes","Number Of Semiconductor Outputs":"0","Release Value Of Thermoresistor":"1 500 ... 1 650 Ω","Current/Voltage Measuring Module":"No","Input For Ground Fault Detection":"No","Response Value Of Thermoresistor":"3 400 ... 3 800 Ω","protocol is supported Modbus RTU":"No","protocol is supported EtherNet/IP":"No","I&M0 - device-specific information":"Yes","protocol is supported OPC UA Server":"Yes","Input For Analog Temperature Sensors":"No","Surge Voltage Resistance Rated Value":"4 000 V","supports PROFIenergy measured values":"Yes","EMC immunity according to IEC 60947-1":"corresponds to degree of severity 3","Product Function Soft Starter Control":"Yes","at the Ethernet interface Autosensing":"Yes","during storage according to IEC 60721":"1K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2 (sand must not get into the devices), 1M4","Pole-Changing Switch Reversing Circuit":"No","according to ATEX directive 2014/34/EU":"BVS 06 ATEX F001","Wire Length For Digital Signals Maximum":"300 m","at the Ethernet interface Autocrossover":"Yes","due to burst according to IEC 61000-4-4":"2 kV (power ports) / 1 kV (signal ports)","during operation according to IEC 60721":"3K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2","reference code according to IEC 81346-2":"F","Finely Stranded With Core End Processing":"1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)","Monitoring Of Number Of Start Operations":"Yes","protocol is supported PROFIsafe protocol":"No","Evaluation Of Thermistor Motor Protection":"Yes","Touch Protection Against Electrical Shock":"finger-safe","at the Ethernet interface Autonegotiation":"Yes","protocol is supported PROFIBUS DP protocol":"No","protocol is supported PROFINET IO protocol":"Yes","Tightening Torque With Screw-Type Terminals":"0.8 ... 1.2 N·m","Buffering Time In The Event Of Power Failure":"0.02 s","is supported PROFINET system redundancy (S2)":"Yes","Design Of Short-Circuit Protection Per Output":"Fuse links: gG 6 A, quick-response 10 A (IEC 60947-5-1), miniature circuit-breaker C char.: 1.6 A (IEC 60947-5-1) or 6 A (I_K < 500 A)","Type Of Voltage Of The Control Supply Voltage":"AC/DC","With Conductor Cross-Section = 0.5 Mm2 Maximum":"50 m","With Conductor Cross-Section = 1.5 Mm2 Maximum":"150 m","With Conductor Cross-Section = 2.5 Mm2 Maximum":"250 m","Electrical Endurance (Operating Cycles) Typical":"100 000","input voltage at digital input at DC rated value":"24 V","EMC emitted interference according to IEC 60947-1":"class A","Mechanical Service Life (Operating Cycles) Typical":"10 000","electrostatic discharge according to IEC 61000-4-2":"6 kV contact discharge / 8 kV air discharge","I&M1 - higher level designation/location designation":"Yes","contact rating of auxiliary contacts according to UL":"B300 / R300","Tightening Torque [Lbf·In] With Screw-Type Terminals":"7 ... 10.3 lbf·in","product function is supported Device Level Ring (DLR)":"No","protocol is supported Media Redundancy Protocol (MRP)":"Yes","Number Of Outputs As Contact-Affected Switching Element":"3","protocol is supported Address Resolution Protocol (ARP)":"Yes","Media Redundancy Protocol for Planned Duplication (MRPD)":"Yes","conducted HF interference emissions according to CISPR11":"corresponds to degree of severity A","Total Cold Resistance Number Of Sensors In Series Maximum":"1.5 kΩ","field-bound HF interference emission according to CISPR11":"corresponds to degree of severity A","Number Of Digital Inputs With A Common Reference Potential":"4","Type Of Electrical Connection Of The Communication Interface":"2x RJ45","insulation voltage with degree of pollution 3 at AC rated value":"300 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"Yes","Relative Symmetrical Tolerance Of The Control Supply Voltage Frequency":"5 %"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/bba568e3bad225c2562fca04211c5e50.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1648935&mlfb=3UF7011-1AU00-1-ZI41"},"ai":{"faq":[{"question":"How can I order Siemens 3UF7011-1AU00-1-ZI41?","answer":"Siemens 3UF7011-1AU00-1-ZI41 is available to order."},{"question":"Can 3UF7011-1AU00-1-ZI41 replace 3UF7011-1AU00-1?","answer":"The base order code 3UF7011-1AU00-1 shares the same core hardware platform. The -ZI41 suffix indicates a specific variant — verify the I/O configuration and firmware version in your existing application before substituting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3UF7011-1AU00-1-ZI41","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3UF7011-1AU00-1-ZI41 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}