{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3UF7101-1AA00-0","brand":"Siemens","brandSlug":"siemens","productSlug":"3UF7101-1AA00-0","canonicalUrl":"https://aoctrl.com/siemens/3UF7101-1AA00-0","factsUrl":"https://aoctrl.com/api/mcp/products/3UF7101-1AA00-0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3UF7101-1AA00-0 current measuring module, IP20, CLASS 5E trip class, 110-690 V AC, 50/60 Hz, screw and snap-on mounting.","salesMarkdown":"## Motor branch monitoring without the extra wiring The 3UF7101-1AA00-0 is a SIRIUS current measuring module that sits in the motor feeder between the contactor and the overload relay — or replaces the overload relay entirely when paired with a SIRIUS 3UF7 evaluation unit. It measures current and provides overload protection with a CLASS 5E trip characteristic, meaning it tracks the thermal load of the motor winding over time and trips on a sustained overcurrent, not just an instantaneous spike. Rated voltage covers 110-690 V AC at 50 or 60 Hz, so it fits standard North American 480 V and European 400 V motor circuits without a separate voltage tap. The module draws only 0.2 W from the control circuit — negligible for the bus power budget in a dense panel. IP20 means it is intended for enclosed panels only; no washdown or outdoor exposure. Vibration resistance is rated at 1-6 Hz / 15 mm and 6-500 Hz / 2 g, which covers the typical shake from contactor pick-up and nearby rotating machinery inside a panel. Altitude derating applies above 2000 m: full spec up to 2000 m, then 3000 m max with +50 °C ambient limit, and 4000 m max with +40 °C limit — relevant for high-altitude installations like mining or mountain-site conveyors. UKCA certification (ITS21UKEX0464) is on file, covering the UK market. The module carries RoHS substance prohibition dated 05/28/2009, which aligns with the original RoHS directive.","metaTitle":"Siemens 3UF7101-1AA00-0 SIRIUS Current Measuring Module","metaDescription":"Siemens 3UF7101-1AA00-0 SIRIUS current measuring module with overload protection, CLASS 5E trip, 110-690 V AC, IP20. Active production — quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLC I/O & Expansion Modules"],"specifications":{"Top":"30 mm","Left":"0 mm","Depth":"45 mm","Right":"0 mm","Width":"45 mm","title":"3UF7101-1AA00-0","Bottom":"30 mm","Height":"84 mm","1 Maximum":"2 000 m","2 Maximum":"3 000 m; max. +50 °C (no protective separation)","3 Maximum":"4 000 m; max. +40 °C (no protective separation)","Trip Class":"CLASS 5E","description":"Current measuring module, Set current 2.4...25 A Overall width 45 mm, straight-through transformer","During Storage":"-40 ... +80 °C","Type Of Voltage":"AC","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-40 ... +80 °C","Fastening Method":"screw and snap-on mounting","Current Detection":"Yes","Mounting Position":"any","Power Measurement":"No","Voltage Detection":"No","according to UKCA":"ITS21UKEX0464","Product Brand Name":"SIRIUS","Current Measurement":"Yes","Overload Protection":"Yes","Product Designation":"Current measuring module","Voltage Measurement":"No","protection class IP":"IP20","Vibration Resistance":"1-6 Hz / 15 mm; 6-500 Hz / 2 g","at 50 Hz rated value":"110 ... 690 V","at 60 Hz rated value":"110 ... 690 V","Consumed Active Power":"0.2 W","Frequency Measurement":"No","Ground-Fault Monitoring":"No","Power Factor Monitoring":"No","Active Power Measurement":"No","Diameter Of Inlet Opening":"7.5 mm","Substance Prohibitance (Date)":"05/28/2009","Input For Thermistor Connection":"No","Operating Frequency Rated Value":"50 ... 60 Hz","Relative Humidity During Operation":"5 ... 95 %","Surge Voltage Resistance Rated Value":"6 000 V","EMC immunity according to IEC 60947-1":"corresponds to degree of severity 3","during storage according to IEC 60721":"1K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2 (sand must not get into the devices), 1M4","according to ATEX directive 2014/34/EU":"BVS 06 ATEX F001","due to burst according to IEC 61000-4-4":"2 kV","during operation according to IEC 60721":"3K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2","reference code according to IEC 81346-2":"F","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"No","shock resistance according to IEC 60068-2-27":"15g / 11 ms","with degree of pollution 3 at AC rated value":"690 V","Diameter Of Inlet Opening For Current Measurement":"7.5 mm","EMC emitted interference according to IEC 60947-1":"class A","Number Of Outputs As Contact-Affected Switching Element":"0","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"2.4 ... 25 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$83.82","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ccd9dae79bc0595822aa317d0cffafe9.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=162567&mlfb=3UF7101-1AA00-0"},"ai":{"faq":[{"question":"Where can I buy 3UF7101-1AA00-0 and how do I get a price?","answer":"We source this module through independent distribution. Submit an RFQ with your target quantity; we will confirm availability and current pricing at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3UF7101-1AA00-0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3UF7101-1AA00-0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}