{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3UF7110-1AA01-0","brand":"Siemens","brandSlug":"siemens","productSlug":"3UF7110-1AA01-0","canonicalUrl":"https://aoctrl.com/siemens/3UF7110-1AA01-0","factsUrl":"https://aoctrl.com/api/mcp/products/3UF7110-1AA01-0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS Current/Voltage Measuring Module 3UF7110-1AA01-0, 110-690 V AC, 45 mm width.","salesMarkdown":"## What This Module Does The Siemens 3UF7110-1AA01-0 is a SIRIUS current/voltage measuring module that handles 110-690 V AC at 50 or 60 Hz. It detects current, voltage, frequency, energy consumption and ground faults — a single device for motor protection and energy monitoring in a control panel. Overload protection follows trip class CLASS 5E, which means it trips fast enough to protect motor windings from sustained overloads. Energy measurement accuracy is ±5 % in the 0.25–8 A range and ±10 % from 8–32 A, both at 0.85 x 110 V … 1.1 x 690 V, cos φ 0.5–1, 25 °C. Mounts by screw or snap-on on DIN rail — any position. At 45 mm wide, 84 mm tall, 64 mm deep, it occupies one standard 45 mm slot. Top and bottom clearance of 30 mm each gives room for cable entry and air flow. IP20 for protected indoor panels. Terminals accept 1x 0.25–2.5 mm² solid or 2x 0.25–1.0 mm² stranded (AWG 24–14 solid, 20–14 stranded). Vibration resistance: 1–6 Hz / 15 mm, 6–500 Hz / 2 g; 1 g if snapped onto a basic unit. ## Integrator Notes for the Sourcing Decision If your BOM calls for a motor protection module with voltage sensing and ground-fault monitoring under 110–690 V AC, the 3UF7110-1AA01-0 covers all three in one 45 mm unit. The 0.5 W power consumption and inrush current up to 40 A (10× Io) are within typical backplane budgets. Specify it confidently as an active, widely stocked SIRIUS component.","metaTitle":"Siemens 3UF7110-1AA01-0 SIRIUS Module, 110-690 V AC","metaDescription":"Active SIRIUS current/voltage measuring module for motor protection, voltage 110-690 V AC, energy measurement ±5%, ground-fault monitoring, overload protection CLASS 5E. Sourced to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLC I/O & Expansion Modules"],"specifications":{"Top":"30 mm","Left":"0 mm","Depth":"64 mm","Right":"0 mm","Solid":"1x (0.25 ... 2.5 mm²), 2x (0.25 ... 1.0 mm²)","Width":"45 mm","Bottom":"30 mm","Height":"84 mm","1 Maximum":"2 000 m","2 Maximum":"3 000 m; max. +50 °C (no protective separation)","3 Maximum":"4 000 m; max. +40 °C (no protective separation)","Trip Class":"CLASS 5E","During Storage":"-40 ... +80 °C","Type Of Voltage":"AC","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-40 ... +80 °C","Fastening Method":"screw and snap-on mounting","Current Detection":"Yes","Mounting Position":"any","Power Measurement":"Yes","Voltage Detection":"Yes","according to UKCA":"ITS21UKEX0464","Product Brand Name":"SIRIUS","Current Measurement":"Yes","Overload Protection":"Yes","Product Designation":"Current/voltage measuring module","Voltage Measurement":"Yes","at AWG cables solid":"1x (24 ... 14), 2x (24 ... 18)","protection class IP":"IP20","Vibration Resistance":"1-6 Hz / 15 mm; 6-500 Hz / 2 g; with basic unit snapped on: 1g","at 50 Hz rated value":"110 ... 690 V","at 60 Hz rated value":"110 ... 690 V","Consumed Active Power":"0.5 W","Frequency Measurement":"Yes","Inrush Current Maximum":"40 A; 10 x Io","at AWG cables stranded":"1x (20 ... 14), 2x (20 ... 16)","At Energy Measurement 1":"+/- 5 %, 0.25 ... 8 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos phi (0.5...1), 50/60 Hz, 25 °C","At Energy Measurement 2":"+/- 10%, 8 A ... 32 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C","Ground-Fault Monitoring":"Yes","Power Factor Monitoring":"Yes","Active Power Measurement":"Yes","At Cos Phi-Measurement 1":"+/- 1.5 %, 0.4 A ... 8 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos phi (0.5...1), 50/60 Hz, 25 °C","At Cos Phi-Measurement 2":"+/- 5%, 8 A ... 32 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C","Of Frequency Measurement":"+/- 1.5 %, 0.25 A ... 8 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos phi (0.5...1), 50/60 Hz, 25 °C","Diameter Of Inlet Opening":"7.5 mm","For Current Measurement 1":"+/- 1.5 %, in range 0.25 A ... 8 A, in range 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), 50/60 Hz, 25 °C","For Current Measurement 2":"+/- 3%, in range 8 A ... 32 A, in range 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), 50/60 Hz, 25 °C","For Voltage Measurement 1":"+/- 1.5 %, in range 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), 50/60 Hz, 25 °C","temperature drift per °C":"0.02 %/°C; Reference temperature: 25°C","Measured Variable Frequency":"45 ... 65 Hz","At Active Power Measurement 1":"+/- 5 %, 0.25 ... 8 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos phi (0.5...1), 50/60 Hz, 25 °C","At Active Power Measurement 2":"+/- 10%, 8 A ... 32 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C","Substance Prohibitance (Date)":"05/28/2009","At Apparent Power Measurement 1":"+/- 3%, 0.25 A ... 8 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C","At Apparent Power Measurement 2":"+/- 5 %, 8 A ... 32 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos phi (0.5...1), 50/60 Hz, 25 °C","Input For Thermistor Connection":"No","Operating Frequency Rated Value":"50 ... 60 Hz","Relative Humidity During Operation":"10 ... 95 %","Accuracy Of Ground-Fault Monitoring":"In the range 30 % .. 120 %/Is: +/- 10 % (Class CI-A), in range 15 % .. 30 % Ie: +/- 25 % (Class CI-B), both values acc. to IEC 60947-1 Annex T","Surge Voltage Resistance Rated Value":"6 000 V","EMC immunity according to IEC 60947-1":"corresponds to degree of severity 3","during storage according to IEC 60721":"1K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2 (sand must not get into the devices), 1M4","according to ATEX directive 2014/34/EU":"BVS 06 ATEX F001","due to burst according to IEC 61000-4-4":"2 kV","during operation according to IEC 60721":"3K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2","reference code according to IEC 81346-2":"F","Finely Stranded With Core End Processing":"1x (0.25 ... 2.5 mm²), 2x (0.25 ... 1.0 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"No","Measuring Procedure For Current Measurement":"TRMS","Measuring Procedure For Voltage Measurement":"TRMS","shock resistance according to IEC 60068-2-27":"15g / 11 ms; with basic unit snapped on","with degree of pollution 3 at AC rated value":"690 V","Diameter Of Inlet Opening For Current Measurement":"7.5 mm","EMC emitted interference according to IEC 60947-1":"class A","Number Of Outputs As Contact-Affected Switching Element":"0","Tightening Torque At The Measurement Inputs For Voltage":"0.5 ... 0.6 N·m","Tightening Torque [Lbf·In] At The Measurement Inputs For Voltage":"4.4 ... 5.3 lbf·in","Type Of Electrical Connection At The Measurement Inputs For Voltage":"screw-type terminals","Current Measuring Range Extension With External Current Transformers":"Yes","measurable supply voltage between the line conductors at AC maximum rated value":"690 V","Line Conductors And Neutral Conductors Internal Resistance For Voltage Measurement":"1 MΩ; RC-based voltage divider","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.3 ... 4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=725684&mlfb=3UF7110-1AA01-0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3UF7110-1AA01-0/alternatives.json"},"ai":{"faq":[{"question":"Does it measure energy?","answer":"Yes. Energy measurement accuracy is ±5 % from 0.25 to 8 A and ±10 % from 8 to 32 A, over a voltage window of 0.85× to 1.1× rated line-to-line voltage, at 50/60 Hz and 25 °C."},{"question":"What are the mounting dimensions?","answer":"Width 45 mm, height 84 mm, depth 64 mm. Requires 30 mm clearance above and below. Mounts by screw or snap-on on DIN rail, any orientation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3UF7110-1AA01-0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3UF7110-1AA01-0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}