{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3UF7113-1AA00-0","brand":"Siemens","brandSlug":"siemens","productSlug":"3UF7113-1AA00-0","canonicalUrl":"https://aoctrl.com/siemens/3UF7113-1AA00-0","factsUrl":"https://aoctrl.com/api/mcp/products/3UF7113-1AA00-0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3UF7113-1AA00-0, current/voltage measuring module, 110-690 V AC, IP20, CLASS 5E overload protection.","salesMarkdown":"The Siemens 3UF7113-1AA00-0 is a SIRIUS current/voltage measuring module that combines voltage detection, current detection, and active power measurement in a single 120 mm wide enclosure. It provides overload protection with trip class CLASS 5E, making it a compact monitoring point for motor feeder circuits. Consumed active power is 0.3 W, which is negligible for cabinet cooling budgets. Overall dimensions are 120 mm wide, 95 mm high, and 145 mm deep. Wiring terminals accept solid conductors 1x (0.5-4 mm²) or 2x (0.5-2.5 mm²) and the equivalent AWG stranded sizes. Vibration tested to 2 g on the 6-500 Hz band and 15 mm displacement at 1-6 Hz, so it holds up on machine-mounted panels.","metaTitle":"Siemens 3UF7113-1AA00-0 SIRIUS Measuring Module, Active","metaDescription":"Current/voltage measuring module, 110-690 V AC, IP20, overload protection CLASS 5E, active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLC I/O & Expansion Modules"],"specifications":{"Top":"30 mm","Left":"0 mm","Depth":"145 mm","Right":"0 mm","Solid":"1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²)","Width":"120 mm","Bottom":"30 mm","Height":"95 mm","1 Maximum":"2 000 m","2 Maximum":"3 000 m; max. +50 °C (no protective separation)","3 Maximum":"4 000 m; max. +40 °C (no protective separation)","Trip Class":"CLASS 5E","During Storage":"-40 ... +80 °C","Type Of Voltage":"AC","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-40 ... +80 °C","Fastening Method":"screw and snap-on mounting","Current Detection":"Yes","Mounting Position":"any","Power Measurement":"Yes","Voltage Detection":"Yes","Product Brand Name":"SIRIUS","Current Measurement":"Yes","Overload Protection":"Yes","Product Designation":"Current/voltage measuring module","Voltage Measurement":"Yes","protection class IP":"IP20","Vibration Resistance":"1-6 Hz / 15 mm; 6-500 Hz / 2 g","at 50 Hz rated value":"110 ... 690 V","at 60 Hz rated value":"110 ... 690 V","for AWG cables solid":"1x (20 ... 14), 2x (20 ... 14)","Consumed Active Power":"0.3 W","Frequency Measurement":"No","at AWG cables stranded":"1x (20 ... 14), 2x (20 ... 16)","Ground-Fault Monitoring":"No","Power Factor Monitoring":"Yes","Active Power Measurement":"Yes","Diameter Of Inlet Opening":"25 mm","Substance Prohibitance (Date)":"05/28/2009","Input For Thermistor Connection":"No","Operating Frequency Rated Value":"50 ... 60 Hz","Relative Humidity During Operation":"5 ... 95 %","Surge Voltage Resistance Rated Value":"8 000 V","EMC immunity according to IEC 60947-1":"corresponds to degree of severity 3","during storage according to IEC 60721":"1K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2 (sand must not get into the devices), 1M4","according to ATEX directive 2014/34/EU":"BVS 06 ATEX F001","due to burst according to IEC 61000-4-4":"2 kV","during operation according to IEC 60721":"3K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2","reference code according to IEC 81346-2":"F","Finely Stranded With Core End Processing":"1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"No","shock resistance according to IEC 60068-2-27":"15g / 11 ms","with degree of pollution 3 at AC rated value":"690 V","Diameter Of Inlet Opening For Current Measurement":"25 mm","EMC emitted interference according to IEC 60947-1":"class A","Number Of Outputs As Contact-Affected Switching Element":"0","Tightening Torque At The Measurement Inputs For Voltage":"0.8 ... 1.2 N·m","Tightening Torque [Lbf·In] At The Measurement Inputs For Voltage":"7 ... 10.3 lbf·in","Type Of Electrical Connection At The Measurement Inputs For Voltage":"screw-type terminals","Current Measuring Range Extension With External Current Transformers":"No","measurable supply voltage between the line conductors at AC maximum rated value":"690 V","Line Conductors And Neutral Conductors Internal Resistance For Voltage Measurement":"1 MΩ; R-based voltage divider","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"20 ... 200 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$654.05","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9bd5443a7ad0c78bf7f8b3d38902f021.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=31749&mlfb=3UF7113-1AA00-0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3UF7113-1AA00-0/alternatives.json"},"ai":{"faq":[{"question":"What are the physical dimensions and mounting options?","answer":"Width 120 mm, height 95 mm, depth 145 mm. Mounts via screw and snap-on to DIN rail in any orientation. IP20 enclosure protection."},{"question":"What compliance documentation is available?","answer":"The module carries a substance prohibition date of May 28, 2009, indicating RoHS compliance. Other certifications are not detailed in this listing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3UF7113-1AA00-0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3UF7113-1AA00-0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}