{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3UF7510-1AA00-0","brand":"Siemens","brandSlug":"siemens","productSlug":"3UF7510-1AA00-0","canonicalUrl":"https://aoctrl.com/siemens/3UF7510-1AA00-0","factsUrl":"https://aoctrl.com/api/mcp/products/3UF7510-1AA00-0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS ground fault module, 3UF7510-1AA00-0, 1 analog input, type A (AC/pulse DC), IP20, 22.5 mm wide, current lifecycle.","salesMarkdown":"## What this module does Siemens SIRIUS 3UF7510-1AA00-0 is a ground fault monitoring module designed for AC and pulse-shaped DC systems – type A detection. It accepts one analog input for ground fault current, with no outputs; response time max 100 ms. Active power draw is 0.1 W. Mounts on DIN rail via screw and snap-on, 22.5 mm wide, IP20. Wiring uses solid 1x (0.5–4.0 mm²) or 2x (0.5–2.5 mm²); stranded 1x (20–12 AWG) or 2x (20–14 AWG).","metaTitle":"Siemens 3UF7510-1AA00-0 SIRIUS Ground Fault Module, 22.5 mm","metaDescription":"Siemens SIRIUS 3UF7510-1AA00-0 ground fault module, 1 analog input, type A, AC/pulse DC. Active lifecycle, IP20, RoHS compliant. Order via RFQ from independent inventory.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Analog Input Modules"],"specifications":{"Top":"40 mm","Left":"0 mm","Depth":"124 mm","Right":"0 mm","Solid":"1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)","Width":"22.5 mm","Bottom":"40 mm","Height":"92 mm","1 Maximum":"2 000 m","2 Maximum":"3 000 m; max. +50 °C (no protective separation)","3 Maximum":"4 000 m; max. +40 °C (no protective separation)","During Storage":"-40 ... +80 °C","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-40 ... +80 °C","Fastening Method":"screw and snap-on mounting","Number Of Inputs":"1","Mounting Position":"any","Number Of Outputs":"0","Product Brand Name":"SIRIUS","Product Designation":"ground fault modules","at AWG cables solid":"1x (20 ... 14), 2x (20 ... 16)","protection class IP":"IP20","Consumed Active Power":"0.1 W","Response Time Maximum":"100 ms","at AWG cables stranded":"1x (20 ... 12), 2x (20 ... 14)","Number Of Analog Inputs":"1","Number Of Analog Outputs":"0","Number Of Digital Inputs":"0","Substance Prohibitance (Date)":"05/01/2012","Type Of Current For Monitoring":"AC and pulse-shaped direct currents (type A)","Input For Thermistor Connection":"No","Number Of Semiconductor Outputs":"0","Input For Ground Fault Detection":"Yes","Relative Humidity During Operation":"5 ... 95 %","Input For Analog Temperature Sensors":"No","EMC immunity according to IEC 60947-1":"corresponds to degree of severity 3","during storage according to IEC 60721":"1K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2 (sand must not get into the devices), 1M4","Measurable Line Frequency Initial Value":"400 Hz","due to burst according to IEC 61000-4-4":"1 kV","during operation according to IEC 60721":"3K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2","Finely Stranded With Core End Processing":"1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)","Touch Protection Against Electrical Shock":"finger-safe","Measurable Line Frequency Full-Scale Value":"16 Hz","Tightening Torque With Screw-Type Terminals":"0.8 ... 1.2 N·m","shock resistance according to IEC 60068-2-27":"15g / 11 ms","1 Of Residual Current Transformer Connectable":"3UL2302-1A","2 Of Residual Current Transformer Connectable":"3UL2303-1A","3 Of Residual Current Transformer Connectable":"3UL2304-1A","4 Of Residual Current Transformer Connectable":"3UL2305-1A","5 Of Residual Current Transformer Connectable":"3UL2306-1A","6 Of Residual Current Transformer Connectable":"3UL2307-1A","vibration resistance according to IEC 60068-2-6":"1 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g","EMC emitted interference according to IEC 60947-1":"class A","Number Of Sensor Inputs For Ground Fault Detection":"1","electrostatic discharge according to IEC 61000-4-2":"6 kV contact discharge / 8 kV air discharge","Tightening Torque [Lbf·In] With Screw-Type Terminals":"7 ... 10.3 lbf·in","Number Of Outputs As Contact-Affected Switching Element":"0","field-bound HF interference emission according to CISPR11":"corresponds to degree of severity A","Relative Measurement Deviation Of Residual Current Transformer":"2.5 %","Diameter Of Inlet Opening Of Connectable Residual Current Transformer":"35 ... 210 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=534040&mlfb=3UF7510-1AA00-0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3UF7510-1AA00-0/alternatives.json"},"ai":{"faq":[{"question":"What is the response time of the ground fault detection?","answer":"Maximum response time is 100 ms."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3UF7510-1AA00-0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3UF7510-1AA00-0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}