{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3UF7600-1AU01-0","brand":"Siemens","brandSlug":"siemens","productSlug":"3UF7600-1AU01-0","canonicalUrl":"https://aoctrl.com/siemens/3UF7600-1AU01-0","factsUrl":"https://aoctrl.com/api/mcp/products/3UF7600-1AU01-0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS multifunction module, 3UF7600-1AU01-0, 4 digital inputs, 2 relay outputs, 22.5 mm width, IP20, 110-240 V rated supply.","salesMarkdown":"## 22.5 mm wide SIRIUS module — 4 DI, 2 relay DO The Siemens 3UF7600-1AU01-0 is a SIRIUS multifunction module packing 4 digital inputs and 2 relay outputs into a 22.5 mm wide housing — a common slot width on a DIN-rail panel, so it fits without crowding adjacent devices. Rated supply voltage is 110... 240 V, and the relay outputs are monostable — they drop out on power loss, which is the expected behavior for a safety-related or controlled stop in a motor control center. ## Output current ratings across the temperature band The relay outputs carry 6 A at 50 °C and derate to 5 A at 60 °C — the 1 A drop over that 10 °C rise means the module can still switch a small contactor coil or pilot light inside a warm enclosure without losing margin. At 230 V the contacts are rated 3 A; at 120 V they handle 6 A — the lower current at higher voltage reflects the arc-quenching limit of the relay, so stay within the 3 A ceiling when switching a 230 V load. ## IP20 and mounting flexibility IP20 protection means the module is dust-protected but not sealed against moisture — it belongs inside a cabinet, not on the wet side of a washdown zone. Any mounting position is allowed, which simplifies layout in a crowded panel. Operating temperature range is -25 to +60 °C, with storage and transport down to -40 °C — typical for a control-panel device in a heated plant environment.","metaTitle":"Siemens 3UF7600-1AU01-0 SIRIUS Multifunction Module","metaDescription":"Siemens 3UF7600-1AU01-0 SIRIUS multifunction module with 4 digital inputs and 2 relay outputs. Rated 6 A at 50 °C, IP20. Current lifecycle stage.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLC I/O & Expansion Modules"],"specifications":{"Top":"40 mm","Left":"0 mm","Depth":"124.5 mm","Right":"0 mm","Solid":"1x (0.5 ... 2.5 mm²), 2x ( 0.5 ... 1.5 mm²)","Width":"22.5 mm","Bottom":"40 mm","Height":"100 mm","at 24 V":"2 A","at 60 V":"0.55 A","at 120 V":"6 A","at 125 V":"0.25 A","at 230 V":"3 A","1 Maximum":"2 000 m","2 Maximum":"3 000 m; max. +50 °C (no protective separation)","3 Maximum":"4 000 m; No protective separation at 40 °C","at 50 °C":"6 A","at 60 °C":"5 A","Rated Value":"110 ... 240 V","Relay Output":"Yes","Digital Input":"Yes","Initial Value":"0.85","During Storage":"-40 ... +80 °C","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-40 ... +80 °C","Full-Scale Value":"1.1","Number Of Inputs":"4","with NTC maximum":"160 °C","with NTC minimum":"80 °C","Mounting Position":"any","Number Of Outputs":"2","Product Brand Name":"SIRIUS","Switching Behavior":"monostable","Product Designation":"Multifunction module","at AWG cables solid":"1x (20 ... 14), 2x (20 ... 16)","protection class IP":"IP20","with KTY 84 maximum":"300 °C","with KTY 84 minimum":"-40 °C","with Pt 100 maximum":"500 °C","with Pt 100 minimum":"-50 °C","at 50 Hz rated value":"110 ... 240 V","at 60 Hz rated value":"110 ... 240 V","with Pt 1000 maximum":"500 °C","with Pt 1000 minimum":"-50 °C","Consumed Active Power":"0.8 W","Response Time Maximum":"0 s","Open-Circuit Detection":"No","Parameterizable Inputs":"Yes","at AWG cables stranded":"1x (20 ... 12), 2x (20 ... 14)","Number Of Analog Inputs":"0","Parameterizable Outputs":"Yes","Short-Circuit Detection":"Yes","with KTY 83-110 maximum":"175 °C","with KTY 83-110 minimum":"-50 °C","Number Of Analog Outputs":"0","Number Of Digital Inputs":"4","type 1 acc. to IEC 61131":"No","type 2 acc. to IEC 61131":"Yes","temperature drift per °C":"0.05 %/°C","For Ground Fault Detection":"1","according to IEC 60068-2-6":"1 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g","For Temperature Measurement":"1","according to IEC 60068-2-27":"15g / 11 ms","Substance Prohibitance (Date)":"05/01/2012","Type Of Current For Monitoring":"Type A (alternating currents and pulsing DC residual currents)","Input For Thermistor Connection":"No","Number Of Semiconductor Outputs":"0","Input For Ground Fault Detection":"Yes","With A Common Reference Potential":"4","sensor current for Pt 100 typical":"1 mA","Control Supply Voltage Frequency 1":"50 ... 60 Hz","Relative Humidity During Operation":"10 ... 95 %","Input For Analog Temperature Sensors":"Yes","Input For Residual Current Converter":"Yes","Surge Voltage Resistance Rated Value":"4 000 V","A/D conversion time at sensor circuit":"500 ms","EMC immunity according to IEC 60947-1":"corresponds to degree of severity 3","during storage according to IEC 60721":"1K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2 (sand must not get into the devices), 1M4","Measurable Line Frequency Initial Value":"16 Hz","Product Function Ground Fault Detection":"Yes","Wire Length For Digital Signals Maximum":"200 m","due to burst according to IEC 61000-4-4":"2 kV (power ports) / 1 kV (signal ports)","during operation according to IEC 60721":"3K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2","reference code according to IEC 81346-2":"K","Finely Stranded With Core End Processing":"1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²)","Adjustable Current Response Value Current":"40 ... 0.03 A","Product Function Residual Current Display":"Yes","Property Of Contacts Of The Relay Outputs":"Floating NO contacts (NC reaction parameterizable via internal signal conditioning), of which 2 relay outputs connected to common ground and one relay output separately, can be freely assigned to the control functions (e.g. line, star (wye), delta contactor or signaling of the operating state)","Touch Protection Against Electrical Shock":"finger-safe","Measurable Line Frequency Full-Scale Value":"400 Hz","Tightening Torque With Screw-Type Terminals":"0.6 ... 0.8 N·m","Buffering Time In The Event Of Power Failure":"0 s","1 Of Residual Current Transformer Connectable":"3UL2302-1A","2 Of Residual Current Transformer Connectable":"3UL2303-1A","3 Of Residual Current Transformer Connectable":"3UL2304-1A","4 Of Residual Current Transformer Connectable":"3UL2305-1A","5 Of Residual Current Transformer Connectable":"3UL2306-1A","6 Of Residual Current Transformer Connectable":"3UL2307-1A","Design Of Short-Circuit Protection Per Output":"Fuse links: gG 6 A, quick-response 10 A (IEC 60947-5-1), miniature circuit-breaker C char.: 1.6 A (IEC 60947-5-1) or 6 A (I_K < 500 A)","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Electrical Endurance (Operating Cycles) Typical":"100 000","Type Of Connection Technology Of Sensor Circuit":"2-wire or 3-wire connection","input voltage at digital input at DC rated value":"230 V","EMC emitted interference according to IEC 60947-1":"class A","Galvanic Isolation Between Inputs And Electronics":"No","Mechanical Service Life (Operating Cycles) Typical":"10 000 000","electrostatic discharge according to IEC 61000-4-2":"6 kV contact discharge / 8 kV air discharge","contact rating of auxiliary contacts according to UL":"B300 / R300","Tightening Torque [Lbf·In] With Screw-Type Terminals":"5.2 ... 7 lbf·in","Number Of Outputs As Contact-Affected Switching Element":"2","conducted HF interference emissions according to CISPR11":"corresponds to degree of severity A","field-bound HF interference emission according to CISPR11":"corresponds to degree of severity A","Design Of The Sensor For Temperature Measurement Connectable":"PT100 / PT1000 / KTY83-110 / KTY84 / NTC","relative temperature-related measurement deviation at 20 °C":"2 %","Relative Measurement Deviation Of Residual Current Transformer":"7.5 %","insulation voltage with degree of pollution 3 at AC rated value":"300 V","Diameter Of Inlet Opening Of Connectable Residual Current Transformer":"35 ... 210 mm","Product Component Removable Terminal For Auxiliary And Control Circuit":"Yes"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a7b161472d9073d56e17d3633d648f40.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=95408&mlfb=3UF7600-1AU01-0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3UF7600-1AU01-0/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for 3UF7600-1AU01-0?","answer":"It has 4 digital inputs and 2 monostable relay outputs. The relay contacts are rated 6 A at 50 °C (5 A at 60 °C), 3 A at 230 V, and 6 A at 120 V. Supply voltage is 110-240 V. The module is 22.5 mm wide, IP20, and fits any mounting position."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3UF7600-1AU01-0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3UF7600-1AU01-0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}