{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3UG3014-1BL60","brand":"Siemens","brandSlug":"siemens","productSlug":"3UG3014-1BL60","canonicalUrl":"https://aoctrl.com/siemens/3UG3014-1BL60","factsUrl":"https://aoctrl.com/api/mcp/products/3UG3014-1BL60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS active power monitoring relay, 3UG3014-1BL60, rated 196-265 VAC, measures 0.2-10 A, IP20, snap-on mounting.","salesMarkdown":"The Siemens 3UG3014-1BL60 is a SIRIUS-brand active power monitoring relay — it watches real power consumption on a motor or load and trips an output when the power goes above or below a set threshold. That makes it useful for detecting a broken belt, a jammed conveyor, a pump running dry, or a heater element that's failed open. The relay measures current from 0.2 A up to 10 A and operates on a supply voltage of 196 to 265 VAC, 50/60 Hz. The measurable current range of 0.2 to 10 A sets the load you can monitor. Below 0.2 A you won't get a reliable reading; above 10 A you need an external current transformer. The relay's own output contacts are rated 3 A at 250 VAC and also 3 A at 400 VAC (50/60 Hz), so it can directly switch a contactor coil or a PLC input without an interposing relay in most panel voltages. Time delays are adjustable: a start-up delay from 0.3 to 3 seconds to avoid nuisance trips during motor inrush, and a response delay on limit violation from 0.5 to 20 seconds for filtering out transient power dips. The repeat accuracy is 1 % of the set point, which is tight enough for process monitoring. The relay uses snap-on mounting and measures 45 mm wide, 100 mm tall, and 100 mm deep. IP20 protection is for cabinet use only. This is a current-production Siemens SIRIUS component.","metaTitle":"Siemens 3UG3014-1BL60 SIRIUS Active Power Monitoring Relay,","metaDescription":"Siemens SIRIUS 3UG3014-1BL60 active power monitoring relay. Rated 196-265 VAC, measures 0.2-10 A. IP20, snap-on mounting. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Process / Temperature Controllers"],"specifications":{"Depth":"100 mm","Solid":"20 ... 14","Width":"45 mm","Height":"100 mm","Typical":"10 000 000","Upwards":"0 mm","at 24 V":"1 A","Forwards":"0 mm","Stranded":"20 ... 14","at 125 V":"0.2 A","at 250 V":"0.1 A","Backwards":"0 mm","Downwards":"0 mm","At The Side":"0 mm","Rated Value":"196 ... 265 V","Mounting type":"snap-on mounting","When Starting":"0.3 ... 3 s","lifecycle_stage":"current","Product function":"Active power monitoring relay","Delayed Switching":"2","Measurable current":"0.2 ... 10 A","Product brand name":"SIRIUS","Protection class IP":"IP20","at 250 V at 50/60 Hz":"3 A","at 400 V at 50/60 Hz":"3 A","at 50 Hz rated value":"196 ... 265 V","at 60 Hz rated value":"196 ... 265 V","acc. to IEC 60068-2-6":"1 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g","acc. to IEC 60068-2-27":"sinusoidal half-wave 15g / 11 ms","at AWG conductors solid":"2x (20 ... 14)","Relative repeat accuracy":"1 %","With Screw-Type Terminals":"1.2 ... 0.8 N·m","at AC-15 at 230 V typical":"100 000","at AWG conductors stranded":"2x (20 ... 14)","Relative metering precision":"10 %","Type of electrical connection":"screw-type terminals","Operating current at 17 V minimum":"5 mA","With Lower Or Upper Limit Violation":"0.5 ... 20 s","Surge voltage resistance rated value":"6 kV","Reference code acc. to DIN EN 61346-2":"K","Reference code acc. to DIN EN 81346-2":"K","With Degree Of Pollution 3 Rated Value":"690 V","Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²","Number of poles for main current circuit":"3","Type of voltage of the control supply voltage":"AC","Buffering time in the event of power failure minimum":"10 ms","Removable Terminal For Auxiliary And Control Circuit":"No","Continuous current of the DIAZED fuse link of the output relay":"4 A","Supply voltage frequency for auxiliary and control current circuit rated value":"50 ... 60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/3UG3014-1BL60/alternatives.json"},"ai":{"faq":[{"question":"What is the measurable current range and what does it mean for my application?","answer":"The relay measures from 0.2 A to 10 A directly. Below 0.2 A the signal is too low; above 10 A you'll need an external current transformer to step down the load current."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3UG3014-1BL60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3UG3014-1BL60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}