{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3UG3014-1BP60","brand":"Siemens","brandSlug":"siemens","productSlug":"3UG3014-1BP60","canonicalUrl":"https://aoctrl.com/siemens/3UG3014-1BP60","factsUrl":"https://aoctrl.com/api/mcp/products/3UG3014-1BP60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS active power monitoring relay, 3UG3014-1BP60, rated 340-460 V AC, 0.2-10 A measurable current, IP20, screw terminals.","salesMarkdown":"The Siemens 3UG3014-1BP60 is a SIRIUS active power monitoring relay — it watches real power consumption on a motor or load and trips an internal relay when the power goes outside a set window. That makes it useful for detecting a broken belt, a jammed conveyor, a dry-running pump, or a load that's drifted off its normal draw. The relay measures current from 0.2 A up to 10 A and accepts a supply voltage of 340-460 V AC at both 50 Hz and 60 Hz. The trip delay is adjustable: 0.3-3 s on startup to ride through inrush, and 0.5-20 s on an upper or lower limit violation to ignore short transients. Two changeover contacts (delayed switching) handle the output, rated 3 A at 250 V AC or 400 V AC, 50/60 Hz. For DC loads, the contacts are rated 1 A at 24 V, 0.2 A at 125 V, and 0.1 A at 250 V. IP20 finger-safe housing. Tightening torque 1.2-0.8 N·m. Zero clearance needed above, below, forward, backward, or to the side — the relay can be butted against other devices without derating. Vibration tested per IEC 60068-2-6: 1-6 Hz at 15 mm amplitude, 6-500 Hz at 2 g. Shock tested per IEC 60068-2-27: 15 g / 11 ms half-sine. Surge voltage resistance rated 6 kV. Repeat accuracy of the power measurement is 1 %; metering precision is 10 %.","metaTitle":"Siemens 3UG3014-1BP60 SIRIUS Active Power Monitoring Relay,","metaDescription":"Siemens SIRIUS 3UG3014-1BP60 active power monitoring relay. Rated 340-460 V AC, 0.2-10 A measurable current. IP20, snap-on mounting. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Process / Temperature Controllers"],"specifications":{"Depth":"100 mm","Solid":"20 ... 14","Width":"45 mm","Height":"100 mm","Typical":"10 000 000","Upwards":"0 mm","at 24 V":"1 A","Forwards":"0 mm","Stranded":"20 ... 14","at 125 V":"0.2 A","at 250 V":"0.1 A","Backwards":"0 mm","Downwards":"0 mm","At The Side":"0 mm","Rated Value":"340 ... 460 V","Mounting type":"snap-on mounting","When Starting":"0.3 ... 3 s","lifecycle_stage":"current","Product function":"Active power monitoring relay","Delayed Switching":"2","Measurable current":"0.2 ... 10 A","Product brand name":"SIRIUS","Protection class IP":"IP20","at 250 V at 50/60 Hz":"3 A","at 400 V at 50/60 Hz":"3 A","at 50 Hz rated value":"340 ... 460 V","at 60 Hz rated value":"340 ... 460 V","acc. to IEC 60068-2-6":"1 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g","acc. to IEC 60068-2-27":"sinusoidal half-wave 15g / 11 ms","at AWG conductors solid":"2x (20 ... 14)","Relative repeat accuracy":"1 %","With Screw-Type Terminals":"1.2 ... 0.8 N·m","at AC-15 at 230 V typical":"100 000","at AWG conductors stranded":"2x (20 ... 14)","Relative metering precision":"10 %","Type of electrical connection":"screw-type terminals","Operating current at 17 V minimum":"5 mA","With Lower Or Upper Limit Violation":"0.5 ... 20 s","Surge voltage resistance rated value":"6 kV","Reference code acc. to DIN EN 61346-2":"K","Reference code acc. to DIN EN 81346-2":"K","With Degree Of Pollution 3 Rated Value":"690 V","Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²","Number of poles for main current circuit":"3","Type of voltage of the control supply voltage":"AC","Buffering time in the event of power failure minimum":"10 ms","Removable Terminal For Auxiliary And Control Circuit":"No","Continuous current of the DIAZED fuse link of the output relay":"4 A","Supply voltage frequency for auxiliary and control current circuit rated value":"50 ... 60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/3UG3014-1BP60/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this relay?","answer":"Supply voltage 340-460 V AC, measurable current 0.2-10 A, output contacts rated 3 A at 250/400 V AC. Adjustable start-up delay 0.3-3 s and limit violation delay 0.5-20 s."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3UG3014-1BP60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3UG3014-1BP60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}