{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3UG4511-1AQ20","brand":"Siemens","brandSlug":"siemens","productSlug":"3UG4511-1AQ20","canonicalUrl":"https://aoctrl.com/siemens/3UG4511-1AQ20","factsUrl":"https://aoctrl.com/api/mcp/products/3UG4511-1AQ20","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3UG4511-1AQ20 phase monitoring relay, 420-690 VAC 50/60 Hz, 3 A rated, snap-on mounting, IP20.","salesMarkdown":"It's a single-function unit with a changeover contact rated 3 A at 250/400 VAC, and a separate auxiliary contact rated 1 A at 24 VDC or 0.1 A at 250 VAC. The 420-690 VAC rated range covers standard 400 V and 690 V three-phase networks without needing a separate voltage tap. The 3 A contact rating at 250/400 VAC is enough to drive a contactor coil or small pilot load; if you're switching a larger contactor, interpose a slave relay. The separate auxiliary contact (1 A at 24 VDC) is useful for a PLC input or status lamp. Auto-reset is enabled by default — the relay re-energizes once the monitored phase returns within tolerance, which suits unattended restart applications. The 22.5 mm width and snap-on DIN mounting mean it occupies one standard module slot; any mounting position is allowed.","metaTitle":"Siemens 3UG4511-1AQ20 SIRIUS Phase Monitoring Relay, 420-690","metaDescription":"Siemens SIRIUS 3UG4511-1AQ20 phase monitoring relay for AC systems, 420-690 VAC 50/60 Hz, 3 A contacts, IP20, snap-on DIN rail. Active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"NRND","categoryPath":["Process / Temperature Controllers"],"specifications":{"Depth":"91 mm","Solid":"20 ... 14","Width":"22.5 mm","Height":"83 mm","Upwards":"0 mm","at 24 V":"1 A","Forwards":"0 mm","Stranded":"20 ... 14","at 125 V":"0.2 A","at 250 V":"0.1 A","Backwards":"0 mm","Downwards":"0 mm","auto-RESET":"Yes","At The Side":"0 mm","Initial Value":"1","During Storage":"-40 ... +85 °C","For Monitoring":"AC","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-40 ... +85 °C","Fastening Method":"snap-on mounting","Full-Scale Value":"1","Product Function":"Phase monitoring relay","Delayed Switching":"1","Mounting Position":"any","Product Brand Name":"SIRIUS","Asymmetry Detection":"No","Between The Outputs":"Yes","Degree Of Pollution":"3","display version LED":"Yes","protection class IP":"IP20","at 250 V at 50/60 Hz":"3 A","at 400 V at 50/60 Hz":"3 A","at 50 Hz rated value":"420 ... 690 V","at 60 Hz rated value":"420 ... 690 V","for AWG cables solid":"2x (20 ... 14)","Design Of The Product":"1 function","Overvoltage Detection":"No","For Auxiliary Contacts":"1","Undervoltage Detection":"No","Phase Failure Detection":"No","for AWG cables stranded":"2x (20 ... 14)","Between Input And Output":"Yes","measurable voltage at AC":"420 ... 690 V","Phase Sequence Recognition":"Yes","Of The Control Supply Voltage":"AC","Overvoltage Detection 3 Phase":"No","Substance Prohibitance (Date)":"05/01/2012","Type Of Electrical Connection":"screw-type terminals","Undervoltage Detection 3 Phases":"No","Voltage Window Recognition 3 Phase":"No","operational current at 17 V minimum":"5 mA","Surge Voltage Resistance Rated Value":"6 kV","With Degree Of Pollution 3 Rated Value":"690 V","due to burst according to IEC 61000-4-4":"2 kV","number of NC contacts delayed switching":"0","number of NO contacts delayed switching":"0","reference code according to IEC 81346-2":"K","Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²","Number Of Poles For Main Current Circuit":"3","Tightening Torque With Screw-Type Terminals":"0.8 ... 1.2 N·m","shock resistance according to IEC 60068-2-27":"sinusoidal half-wave 15g / 11 ms","Between The Voltage Supply And Other Circuits":"Yes","operating frequency with 3RT2 contactor maximum":"5 000 1/h","vibration resistance according to IEC 60068-2-6":"1 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g","Adjustable Open/Closed-Circuit Current Principle":"No","Mechanical Service Life (Operating Cycles) Typical":"10 000 000","electrostatic discharge according to IEC 61000-4-2":"6 kV contact discharge / 8 kV air discharge","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Thermal Current Of The Switching Element With Contacts Maximum":"5 A","continuous current of the DIAZED fuse link of the output relay":"4 A","Product Component Removable Terminal For Auxiliary And Control Circuit":"Yes"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/3UG4511-1AQ20/alternatives.json"},"ai":{"faq":[{"question":"What is the rated voltage range for this relay?","answer":"It monitors AC supplies from 420 to 690 V at 50/60 Hz."},{"question":"What is the contact rating?","answer":"The changeover contact is rated 3 A at 250 VAC and 3 A at 400 VAC. The separate auxiliary contact is rated 1 A at 24 VDC, 0.2 A at 125 VDC, and 0.1 A at 250 VDC."},{"question":"Does it have auto-reset?","answer":"Yes, auto-reset is enabled by default."},{"question":"What is the mounting method and size?","answer":"Snap-on mounting to DIN rail, 22.5 mm wide, 83 mm high, 91 mm deep. IP20 protection. Any mounting position is allowed."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3UG4511-1AQ20","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3UG4511-1AQ20 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}