{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3UG4511-2AQ20","brand":"Siemens","brandSlug":"siemens","productSlug":"3UG4511-2AQ20","canonicalUrl":"https://aoctrl.com/siemens/3UG4511-2AQ20","factsUrl":"https://aoctrl.com/api/mcp/products/3UG4511-2AQ20","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3UG4511-2AQ20 phase monitoring relay, 420...690 V AC, 3 A at 400 V, snap-on mounting, IP20.","salesMarkdown":"The Siemens SIRIUS 3UG4511-2AQ20 is a single-function phase monitoring relay for AC systems. It monitors a three-phase supply between 420 and 690 V at 50 or 60 Hz, with a rated contact current of 3 A at 400 V. The relay detects phase loss or incorrect phase sequence and switches its output accordingly — no asymmetry or over/undervoltage detection built in, so it's a straightforward phase-failure guard. The screw terminals accept solid or stranded wire from 24 to 16 AWG (2 x 24...16 AWG for solid). IP20 rated — fine inside a cabinet, not for wet areas. Depth is 91 mm, so check clearance to the gland plate or door.","metaTitle":"Siemens 3UG4511-2AQ20 SIRIUS Phase Monitoring Relay, 420-690","metaDescription":"Siemens SIRIUS 3UG4511-2AQ20 phase monitoring relay for AC systems. Rated 420-690 V AC, 3 A at 400 V. Snap-on DIN rail mount, IP20. Current lifecycle. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"NRND","categoryPath":["Process / Temperature Controllers"],"specifications":{"Depth":"91 mm","Solid":"24 ... 16","Width":"22.5 mm","Height":"84 mm","Upwards":"0 mm","at 24 V":"1 A","Forwards":"0 mm","Stranded":"24 ... 16","at 125 V":"0.2 A","at 250 V":"0.1 A","Backwards":"0 mm","Downwards":"0 mm","auto-RESET":"Yes","At The Side":"0 mm","Initial Value":"1","During Storage":"-40 ... +85 °C","For Monitoring":"AC","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-40 ... +85 °C","Fastening Method":"snap-on mounting","Full-Scale Value":"1","Product Function":"Phase monitoring relay","Delayed Switching":"1","Mounting Position":"any","Product Brand Name":"SIRIUS","Asymmetry Detection":"No","Between The Outputs":"Yes","Degree Of Pollution":"3","display version LED":"Yes","protection class IP":"IP20","at 250 V at 50/60 Hz":"3 A","at 400 V at 50/60 Hz":"3 A","at 50 Hz rated value":"420 ... 690 V","at 60 Hz rated value":"420 ... 690 V","for AWG cables solid":"2x (24 ... 16)","Design Of The Product":"1 function","Overvoltage Detection":"No","For Auxiliary Contacts":"1","Undervoltage Detection":"No","Phase Failure Detection":"No","for AWG cables stranded":"2x (24 ... 16)","Between Input And Output":"Yes","measurable voltage at AC":"420 ... 690 V","Phase Sequence Recognition":"Yes","Of The Control Supply Voltage":"AC","Overvoltage Detection 3 Phase":"No","Substance Prohibitance (Date)":"05/01/2012","Type Of Electrical Connection":"spring-loaded terminals","Undervoltage Detection 3 Phases":"No","Voltage Window Recognition 3 Phase":"No","operational current at 17 V minimum":"5 mA","Surge Voltage Resistance Rated Value":"6 kV","With Degree Of Pollution 3 Rated Value":"690 V","due to burst according to IEC 61000-4-4":"2 kV","number of NC contacts delayed switching":"0","number of NO contacts delayed switching":"0","reference code according to IEC 81346-2":"K","Finely Stranded With Core End Processing":"0.25 ... 1.5 mm²","Number Of Poles For Main Current Circuit":"3","Finely Stranded Without Core End Processing":"0.25 ... 1.5 mm²","shock resistance according to IEC 60068-2-27":"sinusoidal half-wave 15g / 11 ms","Between The Voltage Supply And Other Circuits":"Yes","operating frequency with 3RT2 contactor maximum":"5 000 1/h","vibration resistance according to IEC 60068-2-6":"1 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g","Adjustable Open/Closed-Circuit Current Principle":"No","Mechanical Service Life (Operating Cycles) Typical":"10 000 000","electrostatic discharge according to IEC 61000-4-2":"6 kV contact discharge / 8 kV air discharge","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Thermal Current Of The Switching Element With Contacts Maximum":"5 A","continuous current of the DIAZED fuse link of the output relay":"4 A","Product Component Removable Terminal For Auxiliary And Control Circuit":"Yes"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/3UG4511-2AQ20/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this phase monitoring relay?","answer":"It monitors 420...690 V AC at 50/60 Hz. The output contact is rated 3 A at 400 V AC (resistive), 1 A at 24 V DC, and 0.1 A at 250 V DC. It detects phase failure and phase sequence only — not asymmetry or over/undervoltage."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3UG4511-2AQ20","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3UG4511-2AQ20 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}