{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3UG4622-1AA30","brand":"Siemens","brandSlug":"siemens","productSlug":"3UG4622-1AA30","canonicalUrl":"https://aoctrl.com/siemens/3UG4622-1AA30","factsUrl":"https://aoctrl.com/api/mcp/products/3UG4622-1AA30","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3UG4622-1AA30, current monitoring relay with digital setting, measuring range 0.05 … 10 A, 22.5 mm width, IP20, snap-on mounting.","salesMarkdown":"The 3UG4622-1AA30: Supply voltage is 24 V DC nominal (20.4–26.4 V), with a contact rated 3 A at 250 V AC for switching alarm or control circuits. The headline measuring range of 0.05 … 10 A is what you set via the digital interface; the relay can actually measure up to 15 A, giving headroom for brief overloads or a wider motor FLA without swapping the unit. Contact rating of 3 A at 250 V AC means it drives a contactor coil or a PLC input directly; at 24 V DC the same contact is rated 1 A. The auto-reset and external reset options let you choose between latching and automatic restart — handy for remote restart of a pump or conveyor. Terminals accept 20–14 AWG solid or stranded, with 2× conductor capacity for looping through. Depth is 91 mm, height 92 mm — leaves room for wiring ducts in a standard 120 mm deep enclosure.","metaTitle":"Siemens 3UG4622-1AA30 SIRIUS Current Monitoring Relay, 0.05-","metaDescription":"Siemens SIRIUS 3UG4622-1AA30 current monitoring relay, digital setting, 0.05-10 A measuring range, 22.5 mm wide, IP20, snap-on mounting. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"NRND","categoryPath":["Process / Temperature Controllers"],"specifications":{"1":"0.05 ... 10 A","2":"0.05 ... 10 A","Depth":"91 mm","Solid":"20 ... 14","Width":"22.5 mm","Height":"92 mm","Upwards":"0 mm","at 24 V":"1 A","Forwards":"0 mm","Stranded":"20 ... 14","at 125 V":"0.2 A","at 250 V":"0.1 A","at 50 Hz":"20.4 ... 26.4 V","at 60 Hz":"20.4 ... 26.4 V","Backwards":"0 mm","Downwards":"0 mm","auto-RESET":"Yes","At The Side":"0 mm","When Starting":"0.1 ... 20 s","During Storage":"-40 ... +85 °C","External Reset":"Yes","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-40 ... +85 °C","Fastening Method":"snap-on mounting","Product Function":"Current monitoring relay","Mounting Position":"any","Measurable Current":"0.05 ... 15 A","Product Brand Name":"SIRIUS","Between The Outputs":"Yes","Degree Of Pollution":"3","Product Designation":"Current monitoring relay with digital setting","protection class IP":"IP20","at 250 V at 50/60 Hz":"3 A","at 400 V at 50/60 Hz":"3 A","at 50 Hz rated value":"24 V","at 60 Hz rated value":"24 V","for AWG cables solid":"2x (20 ... 14)","Design Of The Display":"LCD","supply voltage 1 at DC":"20.4 ... 26.4 V","for AWG cables stranded":"2x (20 ... 14)","Between Input And Output":"Yes","For Main Current Circuit":"screw-type terminals","Relative Repeat Accuracy":"1 %","overcurrent detection DC":"Yes","Measurable Line Frequency":"40 ... 500 Hz","temperature drift per °C":"0.1 %/°C","undercurrent detection DC":"Yes","Accuracy Of Digital Display":"+/-1 digit","Relative Metering Precision":"5 %","Operating Voltage Rated Value":"24 ... 24 V","Overcurrent Detection 1 Phase":"Yes","Overcurrent Detection 3 Phase":"No","Substance Prohibitance (Date)":"05/01/2012","current window recognition DC":"Yes","Type Of Current For Monitoring":"AC/DC","Undercurrent Detection 1 Phase":"Yes","Undercurrent Detection 3 Phases":"No","For Auxiliary And Control Circuit":"screw-type terminals","Design Of The Electrical Isolation":"Protective separation","Voltage Window Recognition 1 Phase":"No","Voltage Window Recognition 3 Phase":"No","supply voltage 1 at DC rated value":"24 V","With Lower Or Upper Limit Violation":"0.1 ... 20 s","operational current at 17 V minimum":"0.005 A","Surge Voltage Resistance Rated Value":"4 kV","Between Control And Auxiliary Circuit":"300 V","Type Of Voltage Of The Supply Voltage":"AC/DC","With Degree Of Pollution 3 Rated Value":"690 V","Between Auxiliary And Auxiliary Circuit":"300 V","due to burst according to IEC 61000-4-4":"2 kV","number of CO contacts delayed switching":"1","number of NC contacts delayed switching":"0","number of NO contacts delayed switching":"0","reference code according to IEC 81346-2":"K","Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²","Number Of Poles For Main Current Circuit":"1","Tightening Torque With Screw-Type Terminals":"0.8 ... 1.2 N·m","Internal Resistance Of The Measuring Circuit":"5 mΩ","shock resistance according to IEC 60068-2-27":"sinusoidal half-wave 15g / 11 ms","Between The Voltage Supply And Other Circuits":"No","operating frequency with 3RT2 contactor maximum":"5 000 1/h","vibration resistance according to IEC 60068-2-6":"1 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g","Adjustable Open/Closed-Circuit Current Principle":"Yes","Mechanical Service Life (Operating Cycles) Typical":"10 000 000","Relative Temperature-Related Measurement Deviation":"5 %","electrostatic discharge according to IEC 61000-4-2":"6 kV contact discharge / 8 kV air discharge","Buffering Time In The Event Of Power Failure Minimum":"10 ms","Product Component Removable Terminal For Main Circuit":"Yes","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Adjustable Switching Hysteresis For Measured Current Value":"10 ... 5 000 mA","Thermal Current Of The Switching Element With Contacts Maximum":"5 A","continuous current of the DIAZED fuse link of the output relay":"4 A","Product Component Removable Terminal For Auxiliary And Control Circuit":"Yes"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/3UG4622-1AA30/alternatives.json"},"ai":{"faq":[{"question":"What is the measuring range of the 3UG4622-1AA30?","answer":"The adjustable monitoring range is 0.05 … 10 A, and the relay can measure up to 15 A for applications needing a wider span."},{"question":"What supply voltage does the 3UG4622-1AA30 need?","answer":"It requires 24 V DC nominal, with an operating range of 20.4 … 26.4 V."},{"question":"What is the contact rating of the 3UG4622-1AA30?","answer":"The output relay is rated 3 A at 250 V AC, 1 A at 24 V DC, and 0.1 A at 250 V DC."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3UG4622-1AA30","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3UG4622-1AA30 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}