{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1010-2ED36-0HC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1010-2ED36-0HC0","canonicalUrl":"https://aoctrl.com/siemens/3VA1010-2ED36-0HC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1010-2ED36-0HC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1010-2ED36-0HC0, 3-pole molded case circuit breaker, 100 A rated continuous current, line protection, TM210 overcurrent release, 52.5 kA at 240 V, 32 kA at 415 V.","salesMarkdown":"## MCCB for Line Protection — 100 A, 3-Pole, High Interrupting Capacity The Siemens SENTRON 3VA1010-2ED36-0HC0 is a 3-pole molded case circuit breaker rated for a continuous current of 100 A at 40 °C, with the TM210 thermal-magnetic overcurrent release providing line protection. It carries a 52.5 kA interrupting capacity at 240 V and 32 kA at 415 V, which means it can safely clear high fault currents in a distribution panel without upstream coordination issues. Above that, it derates linearly: 96 A at 55 °C, 94 A at 60 °C, 92 A at 65 °C, and 90 A at 70 °C. ## Integrated Auxiliary and Shunt Trip No undervoltage release, no ground fault monitoring, and no communication module on this build. The 76.2 mm width (roughly 3 inches) is a common MCCB pitch — it will drop into a panel designed for a 3-pole SENTRON frame without re-drilling. Verify the depth clearance: 70 mm plus wiring space for the line and load lugs.","metaTitle":"Siemens 3VA1010-2ED36-0HC0 SENTRON MCCB, 100 A, 3-Pole, Line","metaDescription":"Siemens SENTRON 3VA1010-2ED36-0HC0 molded case circuit breaker, 100 A rated continuous current, 3-pole, line protection, 52.5 kA at 240 V. Current lifecycle. Sourced to order again","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"52.5 kA","at 415 V":"32 kA","at 440 V":"13.6 kA","at 690 V":"7.5 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96 A","at 60 °C":"94 A","at 65 °C":"92 A","at 70 °C":"90 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"2 auxiliary switches HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL30","Design of the overcurrent release":"TM210","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"No","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 000 A","Adjustable response value current / li min.":"1 000 A","Adjustable response value current / lr min.":"100 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"2","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching capacity class of the circuit breaker":"B","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (1.5 - 70 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=112597&mlfb=3VA1010-2ED36-0HC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1010-2ED36-0HC0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA1010-2ED36-0HC0?","answer":"This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"Will 3VA1010-2ED36-0HC0 drop into a panel specified around 3VA1010-2ED36-0AC0 without rewiring?","answer":"The 3VA1010-2ED36-0HC0 shares the same SENTRON frame dimensions (130 mm height, 76.2 mm width, 70 mm depth) as the -0AC0 variant, so it fits the same mounting footprint. However, the -0HC0 includes a shunt trip and two auxiliary switches, while the -0AC0 may not — verify the control wiring for the auxiliary release before swapping."},{"question":"What compliance documentation does Siemens provide for 3VA1010-2ED36-0HC0?","answer":"As a SENTRON MCCB, it carries the standard Siemens declarations for RoHS and REACH compliance, plus IEC 60947-2 certification for molded case circuit breakers. UL and CSA listings are typical for this series, though specific agency marks should be confirmed on the unit label or via the manufacturer's declaration portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1010-2ED36-0HC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1010-2ED36-0HC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}