{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1010-2ED36-0JA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1010-2ED36-0JA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1010-2ED36-0JA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1010-2ED36-0JA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1010-2ED36-0JA0, 3-pole molded case circuit breaker, 100 A at 40 °C, 52.5 kA at 240 V, TM210 release, shunt trip.","salesMarkdown":"The Siemens 3VA1010-2ED36-0JA0 is a 3-pole SENTRON molded case circuit breaker rated for 100 A continuous at 40 °C, with a TM210 thermal-magnetic overcurrent release and an integrated shunt trip (STL) auxiliary release. Breaking capacity hits 52.5 kA at 240 V, tapering to 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 500 V and 690 V — enough for most industrial panel fault-current levels up to the 240 V secondary side of a distribution transformer. At 40 °C, 45 °C, and 50 °C the breaker holds a full 100 A; derating begins at 55 °C (98 A), dropping to 91 A at 70 °C. That 70 °C operating maximum matches the upper end of the ambient range, so the breaker can sit in a warm enclosure without forced cooling as long as load current stays under the derated curve. Dimensions are 70 mm deep, 76.2 mm wide, and 130 mm tall — a standard 3-pole MCCB footprint that fits most Siemens SENTRON panelboards and third-party enclosures without re-drilling. Maximum power loss is 25 W; account for that heat in the enclosure thermal budget if the breaker is fully loaded in a sealed cabinet.","metaTitle":"Siemens 3VA1010-2ED36-0JA0 SENTRON MCCB, 100 A, 52.5 kA","metaDescription":"Siemens SENTRON 3VA1010-2ED36-0JA0 molded case circuit breaker, 3-pole, 100 A rated at 40 °C, 52.5 kA breaking at 240 V. TM210 release, shunt trip. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"52.5 kA","at 415 V":"32 kA","at 440 V":"13.6 kA","at 500 V":"7.5 kA","at 690 V":"7.5 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"98 A","at 60 °C":"96 A","at 65 °C":"94 A","at 70 °C":"91 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"25 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA10102ED360AA0","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL32","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"500 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"B","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"box terminal on both sides","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=173998&mlfb=3VA1010-2ED36-0JA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1010-2ED36-0JA0/alternatives.json"},"ai":{"faq":[{"question":"What does the TM210 release mean on this breaker?","answer":"The TM210 is a thermal-magnetic overcurrent release — the thermal element handles overload protection with a fixed time curve, and the magnetic element provides instantaneous short-circuit protection, tuned for line-protection duty."},{"question":"Does this MCCB include a shunt trip?","answer":"Yes, it is fitted with a shunt trip (STL) auxiliary release, allowing remote tripping via a control voltage signal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1010-2ED36-0JA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1010-2ED36-0JA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}