{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1010-2ED36-0KA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1010-2ED36-0KA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1010-2ED36-0KA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1010-2ED36-0KA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1010-2ED36-0KA0, 3-pole molded case circuit breaker, 100 A rated current (40 °C), 52.5 kA breaking capacity at 240 V, TM210 thermal-magnetic release, shunt trip (STL).","salesMarkdown":"Three-pole, rated 100 A continuous at 40 °C (derated to 91 A at 70 °C), it handles the typical load of a main feeder or large subfeed in a 400 V industrial installation. A built-in shunt trip (STL) allows remote tripping via a control signal, useful for emergency-off or interlock circuits. ## Breaking capacity — where it fits Breaking capacity is 52.5 kA at 240 V, 32 kA at 415 V, and 13.6 kA at 440 V. At 690 V it still interrupts 7.5 kA. For a 400 V panel with a transformer-fed fault current around 25 kA, this breaker holds a comfortable margin. Mounts on a standard DIN rail — 70 mm deep, 76.2 mm wide, 130 mm tall — so it fits a typical 3-pole MCCB slot without forcing a wider enclosure. ## What the shunt trip adds The shunt trip release (STL) is factory-installed, not a field-add-on kit. Apply a control voltage (typically 24 VDC or 110–240 VAC, depending on the STL variant — the order code does not specify the coil voltage, so confirm that at order) and the breaker opens regardless of the handle position. Useful for remote emergency stop, undervoltage protection schemes, or automated load shedding. No undervoltage release is present on this variant.","metaTitle":"Siemens 3VA1010-2ED36-0KA0 SENTRON MCCB, 100A, 52.5kA at 240","metaDescription":"Siemens 3VA1010-2ED36-0KA0 SENTRON molded case circuit breaker, 3-pole, 100A rated at 40°C, 52.5kA breaking at 240V. TM210 release, shunt trip. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"52.5 kA","at 415 V":"32 kA","at 440 V":"13.6 kA","at 500 V":"7.5 kA","at 690 V":"7.5 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"98 A","at 60 °C":"96 A","at 65 °C":"94 A","at 70 °C":"91 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"25 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA10102ED360AA0","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL33","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"500 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"B","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"box terminal on both sides","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=461604&mlfb=3VA1010-2ED36-0KA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1010-2ED36-0KA0/alternatives.json"},"ai":{"faq":[{"question":"Who supplies 3VA1010-2ED36-0KA0 and how is it quoted for volume purchases?","answer":"This part is sourced to order through independent distribution channels. Availability and current pricing are confirmed at quote time against an RFQ — no stock count or price is published here."},{"question":"What is 3VA1010-2ED36-0KA0's listed depth?","answer":"The depth is 70 mm (2.76 in). Width is 76.2 mm (3 in), height 130 mm (5.12 in)."},{"question":"Will 3VA1010-2ED36-0KA0 drop into a panel specified around 3VA1010-2ED32-0AD0 without rewiring?","answer":"The 3VA1010-2ED36-0KA0 shares the same 3-pole form factor and DIN-rail footprint as the 3VA1010-2ED32-0AD0, so mechanical fit is identical. The functional difference is the shunt trip (STL) on this variant versus the other release options on the 2ED32-0AD0 — wiring for the shunt trip coil would need to be added if not already present."},{"question":"What compliance documentation does this brand provide for 3VA1010-2ED36-0KA0?","answer":"Siemens SENTRON MCCBs typically carry CE, UL, CSA, and IEC 60947-2 certifications. RoHS and REACH declarations are available from the manufacturer. Specific cert numbers for this order code should be confirmed at order."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1010-2ED36-0KA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1010-2ED36-0KA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}