{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1010-2ED36-0KH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1010-2ED36-0KH0","canonicalUrl":"https://aoctrl.com/siemens/3VA1010-2ED36-0KH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1010-2ED36-0KH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1010-2ED36-0KH0, molded case circuit breaker, 3-pole, 100 A at 40 °C, breaking capacity 52.5 kA at 240 V AC, 70 mm depth.","salesMarkdown":"At 55 °C it still holds 98 A, and at 70 °C it derates to 91 A — so in a warm enclosure you lose less than 10 % of the rating. Breaking capacity runs from 52.5 kA at 240 V down to 7.5 kA at 690 V, which covers most industrial service-entrance and feeder applications where fault currents are known. ## Auxiliary and release options built in The basic switch variant is 3VA10102ED360AA0. Measures 76.2 mm wide (3 in), 130 mm tall (5.12 in), and 70 mm deep (2.76 in) — standard SENTRON 3VA1 footprint. ## Environmental range and handling The trip indicator and voltage-trigger status are present, so you get local visual feedback on the breaker state.","metaTitle":"Siemens 3VA1010-2ED36-0KH0 SENTRON MCCB, 100A, 52.5kA at 240","metaDescription":"Siemens SENTRON 3VA1010-2ED36-0KH0 molded case circuit breaker, 3-pole, 100A rated at 40°C, 52.5kA breaking capacity at 240V AC. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"52.5 kA","at 415 V":"32 kA","at 440 V":"13.6 kA","at 500 V":"7.5 kA","at 690 V":"7.5 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"98 A","at 60 °C":"96 A","at 65 °C":"94 A","at 70 °C":"91 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"25 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA10102ED360AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL33","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"500 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"3","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching Capacity Class Of The Circuit Breaker":"B","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"box terminal on both sides","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=189969&mlfb=3VA1010-2ED36-0KH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1010-2ED36-0KH0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA1010-2ED36-0KH0 at different voltages?","answer":"Breaking capacity is 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at both 500 V and 690 V."},{"question":"Will 3VA1010-2ED36-0KH0 drop into a panel specified around 3VA1010-2ED32-0AD0 without rewiring?","answer":"Both are 3-pole SENTRON 3VA1 breakers with the same 76.2 mm width and 130 mm height, so the mechanical footprint is identical. The 2ED36 variant carries a higher continuous current rating (100 A vs the 2ED32's rating) and different breaking capacity; verify the load and fault-current requirements before substituting."},{"question":"Where can I buy 3VA1010-2ED36-0KH0?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit a request for current pricing and availability."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1010-2ED36-0KH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1010-2ED36-0KH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}