{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1010-3ED32-0DA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1010-3ED32-0DA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1010-3ED32-0DA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1010-3ED32-0DA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1010-3ED32-0DA0, 3-pole molded case circuit breaker, line protection, 100 A continuous, TM210 overcurrent release, 75.6 kA at 240 V, with undervoltage release.","salesMarkdown":"The Siemens SENTRON 3VA1010-3ED32-0DA0 is a 3-pole molded case circuit breaker rated for line protection, carrying a continuous current of 100 A up to 50 °C and derating to 90 A at 70 °C. Its TM210 overcurrent release handles the thermal-magnetic trip curve for feeder and distribution panels. The 75.6 kA breaking capacity at 240 V gives solid fault-clearing headroom on low-voltage switchboards; at 415 V it still breaks 52.5 kA, and at 690 V it holds 7.5 kA — enough for most industrial distribution sections without cascading upstream. Width 76.2 mm, depth 70 mm, height 130 mm — fits the standard 3-pole MCCB footprint on a DIN rail or panel-mount base. The lifecycle stage is current — this is an active catalog part from the SENTRON 3VA family. No phase-out or last-time-buy notice applies.","metaTitle":"Siemens SENTRON 3VA1010-3ED32-0DA0 MCCB, 100 A, 75.6 kA at 2","metaDescription":"Siemens SENTRON 3VA1010-3ED32-0DA0 3-pole MCCB, 100 A rated continuous current, 75.6 kA at 240 V, TM210 release, undervoltage release. Sourced to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"75.6 kA","at 415 V":"52.5 kA","at 440 V":"32 kA","at 690 V":"7.5 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96 A","at 60 °C":"94 A","at 65 °C":"92 A","at 70 °C":"90 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB25","Design of the overcurrent release":"TM210","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"No","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 000 A","Adjustable response value current / li min.":"1 000 A","Adjustable response value current / lr min.":"100 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LI","Switching capacity class of the circuit breaker":"N","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"17 x 6.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"12 x 0"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=148687&mlfb=3VA1010-3ED32-0DA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1010-3ED32-0DA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA1010-3ED32-0DA0 and get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time."},{"question":"Will 3VA1010-3ED32-0DA0 drop into a panel specified around 3VA1010-2ED32-0JA0 without rewiring?","answer":"The 3VA1010-3ED32-0DA0 shares the same 3-pole MCCB footprint — 76.2 mm wide, 70 mm deep, 130 mm high — as other 3VA1010 frame breakers, so it fits the same mounting and bus-bar spacing. The key difference is the integrated undervoltage release on the -3ED32 variant; the -2ED32 variant does not include one. If the original panel relied on an external UVR or no UVR, you may need to adjust the control wiring or disable the internal release."},{"question":"What compliance documentation does this brand provide for 3VA1010-3ED32-0DA0?","answer":"Siemens SENTRON 3VA circuit breakers carry CE marking for the European market and are designed to meet IEC 60947-2. Documentation includes a declaration of conformity, installation instructions, and a device manual covering the TM210 release and UVR. RoHS and REACH compliance is standard for current-production Siemens industrial controls."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1010-3ED32-0DA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1010-3ED32-0DA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}