{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1010-3ED32-0HH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1010-3ED32-0HH0","canonicalUrl":"https://aoctrl.com/siemens/3VA1010-3ED32-0HH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1010-3ED32-0HH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1010-3ED32-0HH0, 3-pole molded case circuit breaker, rated 100 A continuous, 75.6 kA breaking at 240 V, TM210 thermal-magnetic release, shunt trip, IP40 front.","salesMarkdown":"The Siemens SENTRON 3VA1010-3ED32-0HH0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current at 40 °C, with a TM210 thermal-magnetic overcurrent release and an integrated shunt trip (STL). It delivers 75.6 kA interrupting capacity at 240 V and 52.5 kA at 415 V, making it a strong candidate for main or feeder protection in commercial and light industrial distribution panels where high fault current is a concern. ## What the breaking capacity numbers mean for your panel At 240 V this breaker clears 75.6 kA — that's the SCCR you can count on for a main lug or main breaker panel fed from a large transformer. At 415 V the rating drops to 52.5 kA, and at 440 V it's 32 kA. If your service entrance fault current is above 52.5 kA at 400 V class, you need a higher-rated frame or a current-limiting upstream device. The 690 V rating of 7.5 kA is a formality — nobody uses a 100 A MCCB at 690 V for primary protection. ## Thermal derating and continuous current If you're stuffing this into a crowded enclosure with other heat sources, factor the ambient around the breaker — not the room ambient. ## Auxiliary contacts and trip indication The trip alarm signals on a fault trip, not a manual open — useful for remote fault annunciation or shutting down upstream gear. The front-mounted voltage trigger and mechanical trip indicator give local status without opening the door.","metaTitle":"Siemens SENTRON 3VA1010-3ED32-0HH0 MCCB, 100 A, 75.6 kA at 2","metaDescription":"Siemens SENTRON 3VA1010-3ED32-0HH0 molded case circuit breaker. 3-pole, 100 A rated, 75.6 kA at 240 V. TM210 release, shunt trip, IP40 front. Current lifecycle. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"75.6 kA","at 415 V":"52.5 kA","at 440 V":"32 kA","at 690 V":"7.5 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96 A","at 60 °C":"94 A","at 65 °C":"92 A","at 70 °C":"90 A","Trip indicator":"Yes","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL30","Design of the overcurrent release":"TM210","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"No","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 000 A","Adjustable response value current / li min.":"1 000 A","Adjustable response value current / lr min.":"100 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"3","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching capacity class of the circuit breaker":"N","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"17 x 6.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"12 x 0"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=69222&mlfb=3VA1010-3ED32-0HH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1010-3ED32-0HH0/alternatives.json"},"ai":{"faq":[{"question":"What is the interrupting capacity of this MCCB at 240 V?","answer":"It clears 75.6 kA at 240 V, 52.5 kA at 415 V, and 32 kA at 440 V."},{"question":"Will 3VA1010-3ED32-0HH0 drop into a panel specified around 3VA1010-2ED42-0AE0 without rewiring?","answer":"Both are 3-pole 100 A SENTRON 3VA frames with the same 76.2 mm width and 70 mm depth, so the mechanical fit and bus connection are identical. The difference is in the release: the -3ED32 uses a TM210 thermal-magnetic trip with a shunt trip, while the -2ED42 uses a different release variant. Verify the control wiring for the shunt trip matches your panel schematic before swapping."},{"question":"How do I get current pricing and availability for 3VA1010-3ED32-0HH0?","answer":"This part is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time."},{"question":"What compliance documentation does this part carry?","answer":"As a Siemens SENTRON 3VA series MCCB, it carries CE marking and is designed to IEC 60947-2. Specific documentation (RoHS, REACH, UL) should be confirmed at order — the evidence does not list individual certs."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1010-3ED32-0HH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1010-3ED32-0HH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}