{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1010-3ED32-0KA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1010-3ED32-0KA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1010-3ED32-0KA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1010-3ED32-0KA0","rawCanonicalId":null},"summary":{"shortDescription":"SENTRON 3VA1010-3ED32-0KA0, molded case circuit breaker, 3-pole, 100 A (40 °C), TM210 release, shunt trip (STL), breaking capacity 75.6 kA at 240 V.","salesMarkdown":"The SENTRON 3VA1010-3ED32-0KA0 is a 3-pole molded case circuit breaker (MCCB) rated 100 A at 40 °C, with a TM210 thermal-magnetic overcurrent release and an integrated shunt trip (STL) for remote tripping. Breaking capacity runs 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at both 500 V and 690 V — enough headroom for most industrial distribution panels where fault current is known and coordinated. ## Ratings in context The 100 A rating holds steady from 40 °C through 50 °C, then derates to 98 A at 55 °C, 96 A at 60 °C, 94 A at 65 °C, and 91 A at 70 °C. ## Physical fit No trip indicator on this variant, so plan for a visual check at the breaker handle or add an external indication contact if the spec calls for it.","metaTitle":"SENTRON 3VA1010-3ED32-0KA0 MCCB, 100 A, 3-Pole, Shunt Trip","metaDescription":"SENTRON 3VA1010-3ED32-0KA0 molded case circuit breaker, 100 A at 40 °C, 3-pole, TM210 release, shunt trip (STL), 75.6 kA at 240 V. Current lifecycle stage, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"75.6 kA","at 415 V":"52.5 kA","at 440 V":"32 kA","at 500 V":"7.5 kA","at 690 V":"7.5 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"98 A","at 60 °C":"96 A","at 65 °C":"94 A","at 70 °C":"91 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"25 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA10103ED320AA0","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL33","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"500 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"N","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"nut keeper kit on both ends","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=16904&mlfb=3VA1010-3ED32-0KA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1010-3ED32-0KA0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA1010-3ED32-0KA0 at 415 V?","answer":"52.5 kA at 415 V. It also carries 75.6 kA at 240 V, 32 kA at 440 V, and 7.5 kA at both 500 V and 690 V."},{"question":"Where can I buy 3VA1010-3ED32-0KA0 and get current pricing?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm response."},{"question":"Will 3VA1010-3ED32-0KA0 drop into a panel specified for 3VA1110-5EF32-0LA0?","answer":"Both are 3-pole SENTRON 3VA MCCBs with the same frame height and width, so the mounting footprint and bus bar centers are identical. The main difference is the release type and rating — the 3VA1110-5EF32-0LA0 carries an electronic release with different trip characteristics and a higher amp rating. Verify the coordination study before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1010-3ED32-0KA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1010-3ED32-0KA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}