{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1010-3ED36-0BA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1010-3ED36-0BA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1010-3ED36-0BA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1010-3ED36-0BA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1010-3ED36-0BA0, Molded case circuit breaker, 3-pole, 100 A, TM210 overcurrent release, 75.6 kA breaking capacity at 240 V.","salesMarkdown":"## MCCB for panel protection — 100 A, 3-pole, TM210 release Breaking capacity reaches 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at 690 V — covering most LV fault scenarios without cascading upstream. The 15 000 latching endurance cycles suit frequent-switching applications like motor control centers or capacitor bank switching. ## Mounting and integration — 76.2 mm wide, IP40 front Width at 76.2 mm (3-pole) fits standard MCCB panel cutouts. IP40 on the front face protects against tool entry; the back and sides are unrated, so panel clearance around live busbars is on the installer. No auxiliary contact version fitted as standard. An undervoltage release (UVR) is integrated — design 3VA9608-0BB11 is the trip unit that interfaces with the UVR coil. No communication function, no voltage trigger, no phase failure detection on this variant. For selectivity studies: the 75.6 kA breaking at 240 V and 52.5 kA at 415 V allow this MCCB to serve as a main or feeder breaker upstream of smaller MCBs. The TM210 release is thermal-magnetic — fixed thermal pickup, fixed magnetic trip at 10× In (typical for TM releases). No electronic adjustment, so coordination is curve-based, not programmable.","metaTitle":"Siemens 3VA1010-3ED36-0BA0 SENTRON MCCB, 100 A, 3-Pole, 75.6","metaDescription":"Siemens 3VA1010-3ED36-0BA0 SENTRON molded case circuit breaker, 100 A rated continuous current, 3-pole, TM210 release, 75.6 kA breaking at 240 V. Current production. Quoted to orde","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"75.6 kA","at 415 V":"52.5 kA","at 440 V":"32 kA","at 690 V":"7.5 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96 A","at 60 °C":"94 A","at 65 °C":"92 A","at 70 °C":"90 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB11","Design of the overcurrent release":"TM210","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"No","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 000 A","Adjustable response value current / li min.":"1 000 A","Adjustable response value current / lr min.":"100 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LI","Switching capacity class of the circuit breaker":"N","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (1.5 - 70 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=519407&mlfb=3VA1010-3ED36-0BA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1010-3ED36-0BA0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1010-3ED36-0BA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1010-3ED36-0BA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}