{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1010-3ED36-0BH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1010-3ED36-0BH0","canonicalUrl":"https://aoctrl.com/siemens/3VA1010-3ED36-0BH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1010-3ED36-0BH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1010-3ED36-0BH0, molded case circuit breaker, 3-pole, 100 A, TM210 thermal-magnetic release, line protection, 70 mm depth.","salesMarkdown":"## SENTRON 3VA1010-3ED36-0BH0 — 100 A MCCB, line protection The Siemens 3VA1010-3ED36-0BH0 is a SENTRON molded case circuit breaker (MCCB) rated for 100 A continuous current at 40 °C, with a 3-pole configuration and a TM210 thermal-magnetic overcurrent release. This is the line-protection version — no voltage trigger or ground-fault monitoring — so it's a straight disconnect for feeders and distribution panels where you need selective coordination downstream of a main breaker. Breaking capacity is 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at 690 V. The 100 A rating holds flat from 40 °C through 50 °C, then derates to 96 A at 55 °C, 94 A at 60 °C, 92 A at 65 °C, and 90 A at 70 °C. If this breaker lives in a non-ventilated enclosure near other heat sources, use the 60 °C or 65 °C column — the 90–94 A range still covers a 90 A feeder without oversizing the frame. Footprint is 70 mm deep, 76.2 mm wide, 130 mm tall — standard 3-pole MCCB envelope that clips onto a DIN rail or mounts with screws. The auxiliary contact block part number for replacement is 3VA9608-0BB11. Mechanical endurance is 15,000 operations — typical for a panelboard MCCB that sees occasional switching, not a daily motor-start duty cycle. For higher cycle counts, look at the 3VA2 series with higher endurance ratings.","metaTitle":"Siemens 3VA1010-3ED36-0BH0 SENTRON MCCB, 100A, 3-Pole, TM210","metaDescription":"Siemens 3VA1010-3ED36-0BH0 SENTRON molded case circuit breaker, 100A rated, 3-pole, TM210 thermal-magnetic release, 75.6 kA at 240 V. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"75.6 kA","at 415 V":"52.5 kA","at 440 V":"32 kA","at 690 V":"7.5 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96 A","at 60 °C":"94 A","at 65 °C":"92 A","at 70 °C":"90 A","Trip indicator":"Yes","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB11","Design of the overcurrent release":"TM210","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"No","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 000 A","Adjustable response value current / li min.":"1 000 A","Adjustable response value current / lr min.":"100 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"3","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching capacity class of the circuit breaker":"N","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (1.5 - 70 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=229273&mlfb=3VA1010-3ED36-0BH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1010-3ED36-0BH0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of this MCCB at different voltages?","answer":"75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at 690 V. The 415 V figure is the relevant one for most 400 V three-phase industrial panels."},{"question":"What does the TM210 release mean on this breaker?","answer":"TM210 is a thermal-magnetic overcurrent release — thermal element for overload protection, magnetic element for short-circuit. The '210' indicates a fixed thermal pickup of 100 A (the rated continuous current Iu), with an adjustable magnetic trip range."},{"question":"Does this breaker include an undervoltage release?","answer":"Yes, it comes with a factory-fitted undervoltage release (UVR) as the auxiliary release, plus 2 auxiliary switches and 1 trip alarm switch (HQ configuration)."},{"question":"Where can I buy 3VA1010-3ED36-0BH0 and what is the lead time?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead-time and price quote."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1010-3ED36-0BH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1010-3ED36-0BH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}