{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1010-3ED36-0DA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1010-3ED36-0DA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1010-3ED36-0DA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1010-3ED36-0DA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1010-3ED36-0DA0, molded case circuit breaker, 3-pole, 100 A, TM210 release, line protection, undervoltage release fitted, 70 mm depth.","salesMarkdown":"## SENTRON 3VA1010-3ED36-0DA0 — 100 A MCCB with TM210 release and undervoltage trip The Siemens 3VA1010-3ED36-0DA0 is a SENTRON molded case circuit breaker (MCCB) rated for 100 A continuous current at 40 °C, configured as a 3-pole line-protection device with a TM210 thermal-magnetic release. It carries a rated insulation voltage of 800 V and delivers interrupting capacity of 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at 690 V — figures that govern selectivity coordination downstream. The UVR design is the 3VA9608-0BB25 auxiliary trip unit. The 70 mm depth and 76.2 mm width fit standard SENTRON 3VA panel cutouts, and the 130 mm height leaves clearance for busbar connections above and below. Above that, derating applies linearly: 96 A at 55 °C, 94 A at 60 °C, 92 A at 65 °C, and 90 A at 70 °C. The storage minimum matters for winter site staging before installation. The 3-pole form factor with no auxiliary contact version fitted means the side slots are free for add-on modules (shunt trip, auxiliary switch) if needed later. The TM210 release is fixed — no interchangeable trip unit — so the breaker is ordered at the exact amp rating required. No communication function or phase-failure detection is built in; this is a straight line-protection device with undervoltage release only. For applications requiring remote monitoring or phase-loss protection, an external relay or a different 3VA variant with those features would be needed.","metaTitle":"Siemens 3VA1010-3ED36-0DA0 SENTRON MCCB, 100 A, 3-pole, TM21","metaDescription":"Siemens 3VA1010-3ED36-0DA0 SENTRON molded case circuit breaker, 100 A rated continuous current at 40 °C, 3-pole, TM210 release, 75.6 kA at 240 V. Active production, available to or","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"75.6 kA","at 415 V":"52.5 kA","at 440 V":"32 kA","at 690 V":"7.5 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96 A","at 60 °C":"94 A","at 65 °C":"92 A","at 70 °C":"90 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB25","Design of the overcurrent release":"TM210","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"No","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 000 A","Adjustable response value current / li min.":"1 000 A","Adjustable response value current / lr min.":"100 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LI","Switching capacity class of the circuit breaker":"N","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (1.5 - 70 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=517898&mlfb=3VA1010-3ED36-0DA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1010-3ED36-0DA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA1010-3ED36-0DA0 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the breaking capacity of this MCCB at 415 V?","answer":"At 415 V the interrupting capacity is 52.5 kA. At 240 V it is 75.6 kA, at 440 V it is 32 kA, and at 690 V it is 7.5 kA."},{"question":"Does this breaker include an undervoltage release?","answer":"Yes, an undervoltage release (UVR) is factory-fitted as standard — order code 3VA9608-0BB25 for the auxiliary trip unit. The breaker will trip on loss of control voltage."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1010-3ED36-0DA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1010-3ED36-0DA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}