{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1010-3ED36-0JH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1010-3ED36-0JH0","canonicalUrl":"https://aoctrl.com/siemens/3VA1010-3ED36-0JH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1010-3ED36-0JH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1010-3ED36-0JH0, molded case circuit breaker, 3-pole, 100 A, TM210 release, line protection, 75.6 kA at 240 V.","salesMarkdown":"The interrupting capacity hits 75.6 kA at 240 V and 52.5 kA at 415 V — numbers that matter when you're coordinating with an upstream transformer or a high-fault panel bus. At 440 V it still holds 32 kA, and at 500 V and 690 V it's rated 7.5 kA. The TM210 release is the overcurrent-protection element here — thermal for overload, magnetic for short-circuit. It's a straight line-protection MCCB: feed it, protect the cable, trip on fault. At 55 °C it derates to 98 A, at 60 °C to 96 A, at 65 °C to 94 A, and at 70 °C to 91 A. If the panel ambient sits at 50 °C or below — which covers most ventilated enclosures — you get the full 100 A. Above that, the thermal element in the TM210 release responds earlier; the derating curve is linear enough to plan around. Power loss is 25 W max. ## Panel-fit dimensions Height 130 mm, width 76.2 mm, depth 70 mm. That's a compact 3-pole MCCB for 100 A — it fits in the same cutout as earlier 3VA frames. If your panel was laid out for a 3VA1010-2ED32-0AD0, the footprint is identical, but check the auxiliary wiring — this one carries the HQ contact set (2 aux + 1 alarm) rather than a different configuration.","metaTitle":"Siemens 3VA1010-3ED36-0JH0 SENTRON MCCB, 100 A, 3-Pole, 75.6","metaDescription":"Siemens SENTRON 3VA1010-3ED36-0JH0 molded case circuit breaker, 100 A, 3-pole, 75.6 kA at 240 V. TM210 release, line protection. Current lifecycle. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"75.6 kA","at 415 V":"52.5 kA","at 440 V":"32 kA","at 500 V":"7.5 kA","at 690 V":"7.5 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"98 A","at 60 °C":"96 A","at 65 °C":"94 A","at 70 °C":"91 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Trip Indicator":"Yes","Number Of Poles":"3","Product version":"Line protection","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"25 W","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA10103ED360AA0","Courant permanent assigné Iu":"100 A","Ground-Fault Monitoring Version":"Without","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","reference code / acc. to IEC 81346-2":"Q","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL32","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product Extension / Optional / Motor Drive":"No","Neutral conductors / upgradeable/retrofittable":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"3","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching Capacity Class Of The Circuit Breaker":"N","Max. rated operational current of the frame size":"100 A","Mechanical Service Life (Switching Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"box terminal on both sides","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (1.5 - 70 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=191112&mlfb=3VA1010-3ED36-0JH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1010-3ED36-0JH0/alternatives.json"},"ai":{"faq":[{"question":"What is the interrupting capacity of 3VA1010-3ED36-0JH0 at 415 V?","answer":"52.5 kA at 415 V. At 240 V it's 75.6 kA, at 440 V it's 32 kA, and at 500 V and 690 V it's 7.5 kA."},{"question":"Will 3VA1010-3ED36-0JH0 drop into a panel that was specified around 3VA1010-2ED32-0AD0 without rewiring?","answer":"The physical footprint is the same — 130 mm height, 76.2 mm width, 70 mm depth — so it mounts in the same cutout. The difference is in the auxiliary contact configuration: this unit has 2 aux switches plus 1 trip alarm switch (HQ), while the -2ED32-0AD0 variant may carry a different aux contact set. Check the existing wiring against the HQ pinout before committing."},{"question":"Where can I buy 3VA1010-3ED36-0JH0?","answer":"This MCCB is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment."},{"question":"What compliance documentation does Siemens provide for 3VA1010-3ED36-0JH0?","answer":"Siemens SENTRON MCCBs typically carry UL, CSA, CE, and IEC certifications, and RoHS/REACH declarations are available through the manufacturer's documentation portal. The specific approvals for this order code should be verified against the nameplate marking at receipt."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1010-3ED36-0JH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1010-3ED36-0JH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}