{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1010-4ED32-0DA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1010-4ED32-0DA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1010-4ED32-0DA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1010-4ED32-0DA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1010-4ED32-0DA0, Molded case circuit breaker, 3-pole, 100 A, TM210 overcurrent release, line protection, undervoltage release, IP40 front.","salesMarkdown":"The front face is protected to IP40, meaning it's sealed against tools and small solids but not against moisture ingress; this is a panel-mounted device, not a washdown enclosure. This MCCB delivers 121 kA interrupting capacity at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at 690 V. For a 100 A frame, the 121 kA at 240 V is high enough for most secondary-side distribution; the 11.9 kA at 690 V still covers typical industrial motor-circuit fault levels at that voltage. Above that, it derates linearly: 96 A at 55 °C, 94 A at 60 °C, 92 A at 65 °C, and 90 A at 70 °C. ## Panel fit and mechanical endurance The 76.2 mm width is three 25.4 mm pole pitches — standard for a 3-pole MCCB in a SENTRON 3VA frame. No auxiliary contact version is fitted as shipped; no communication function, no phase failure detection, no ground fault monitoring. The undervoltage release is the only auxiliary release present.","metaTitle":"Siemens 3VA1010-4ED32-0DA0 SENTRON MCCB, 100 A, 3-Pole, Line","metaDescription":"Siemens SENTRON 3VA1010-4ED32-0DA0 molded case circuit breaker, 100 A rated, 3-pole, line protection, TM210 release. Breaking capacity 121 kA at 240 V. Active production. Quoted to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"121 kA","at 415 V":"75.6 kA","at 440 V":"52.5 kA","at 690 V":"11.9 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96 A","at 60 °C":"94 A","at 65 °C":"92 A","at 70 °C":"90 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB25","Design of the overcurrent release":"TM210","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"No","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 000 A","Adjustable response value current / li min.":"1 000 A","Adjustable response value current / lr min.":"100 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LI","Switching capacity class of the circuit breaker":"S","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"17 x 6.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"12 x 0"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=80903&mlfb=3VA1010-4ED32-0DA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1010-4ED32-0DA0/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this MCCB?","answer":"Rated continuous current is 100 A (derated above 50 °C). Breaking capacity is 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at 690 V. Rated insulation voltage is 800 V. It is a 3-pole device with a TM210 thermal-magnetic release."},{"question":"Where can I buy 3VA1010-4ED32-0DA0?","answer":"This part is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment."},{"question":"What is the difference between 3VA1010-4ED32-0DA0 and 3VA1010-2ED42-0AE0?","answer":"The 3VA1010-2ED42-0AE0 is a functional peer in the same 3VA1010 frame and 100 A rating, but it carries a different overcurrent release configuration and auxiliary contact arrangement. The 3VA1010-4ED32-0DA0 includes an undervoltage release (UVR) and uses the TM210 release; the -2ED42-0AE0 variant has a different release code and no UVR. Both share the same physical footprint and pole count, so they will fit the same panel cutout, but the internal trip characteristics and auxiliary wiring differ. Verify the release and auxiliary requirements against your BOM before substituting."},{"question":"What compliance documentation is available for this breaker?","answer":"As a Siemens SENTRON 3VA series MCCB, it carries IEC 60947-2 certification. The manufacturer provides RoHS and REACH declarations in the product documentation. Specific UL listing status should be confirmed against the nameplate marking on the unit received."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1010-4ED32-0DA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1010-4ED32-0DA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}