{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1010-4ED36-0BC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1010-4ED36-0BC0","canonicalUrl":"https://aoctrl.com/siemens/3VA1010-4ED36-0BC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1010-4ED36-0BC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1010-4ED36-0BC0, molded case circuit breaker, 3-pole, 100 A, line protection, TM210 release, 70 mm depth, 76.2 mm width, 130 mm height.","salesMarkdown":"## MCCB for feeder and branch circuit protection The Siemens SENTRON 3VA1010-4ED36-0BC0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current at 40 °C, with a TM210 thermal-magnetic release for line protection in distribution panels and motor control centers. Its interrupting capacity hits 121 kA at 240 V AC and 75.6 kA at 415 V AC, which means it can handle high-fault scenarios at common industrial voltages without cascading failure upstream. ## Breaking capacity and thermal derating At 440 V the breaker still clears 52.5 kA; at 690 V it drops to 11.9 kA — the SCCR headroom shrinks as system voltage rises, so coordination studies need the specific voltage point. Thermal derating is minimal through 50 °C (still 100 A), then steps down to 96 A at 55 °C, 94 A at 60 °C, 92 A at 65 °C, and 90 A at 70 °C — usable in warm enclosures if you account for the drop. ## Panel integration and auxiliary options","metaTitle":"Siemens 3VA1010-4ED36-0BC0 SENTRON MCCB, 100 A, 3-Pole, Line","metaDescription":"Siemens SENTRON 3VA1010-4ED36-0BC0 molded case circuit breaker. 100 A rated continuous current, 3-pole line protection. Breaking capacity 121 kA at 240 V. TM210 release. Available","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"121 kA","at 415 V":"75.6 kA","at 440 V":"52.5 kA","at 690 V":"11.9 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96 A","at 60 °C":"94 A","at 65 °C":"92 A","at 70 °C":"90 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"2 auxiliary switches HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB11","Design of the overcurrent release":"TM210","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"No","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 000 A","Adjustable response value current / li min.":"1 000 A","Adjustable response value current / lr min.":"100 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"2","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching capacity class of the circuit breaker":"S","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (1.5 - 70 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=243033&mlfb=3VA1010-4ED36-0BC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1010-4ED36-0BC0/alternatives.json"},"ai":{"faq":[{"question":"Will 3VA1010-4ED36-0BC0 drop into a panel designed for 3VA1010-2ED36-0AC0?","answer":"Both are 3-pole 100 A SENTRON MCCBs with the same 70 mm depth and 76.2 mm width, so the physical footprint and busbar spacing are identical — no rewiring needed for the mount."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1010-4ED36-0BC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1010-4ED36-0BC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}