{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1010-4ED42-0JA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1010-4ED42-0JA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1010-4ED42-0JA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1010-4ED42-0JA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1010-4ED42-0JA0, molded case circuit breaker, 4-pole, 100 A rated continuous current, TM210 thermal-magnetic release, shunt trip, line protection, breaking capacity 121 kA at 240 V.","salesMarkdown":"## MCCB for 100 A feeder and branch protection Its TM210 thermal-magnetic release provides fixed overload and short-circuit protection without the need for external relays — a straightforward fit for 100 A feeder circuits, busway taps, or large motor branch circuits where adjustable electronic trip is not required. Breaking capacity is 121 kA at 240 V AC, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at 690 V — high enough for most low-voltage distribution systems with high fault current potential. The 100 A rating holds flat from 40 °C to 50 °C, then derates to 96 A at 55 °C, 94 A at 60 °C, 92 A at 65 °C, and 90 A at 70 °C. ## Integrated shunt trip and auxiliary options","metaTitle":"Siemens 3VA1010-4ED42-0JA0 SENTRON MCCB, 100A, 4-Pole, 121kA","metaDescription":"Siemens 3VA1010-4ED42-0JA0 SENTRON molded case circuit breaker, 100A continuous, 4-pole, line protection, TM210 release, shunt trip. Breaking capacity 121kA at 240V. Active product","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"101.6 mm","Height":"130 mm","at 240 V":"121 kA","at 415 V":"75.6 kA","at 440 V":"52.5 kA","at 690 V":"11.9 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96 A","at 60 °C":"94 A","at 65 °C":"92 A","at 70 °C":"90 A","Trip indicator":"No","Number of poles":"4","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL32","Design of the overcurrent release":"TM210","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Design of the N-conductor protection":"Without","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"600 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"No","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 000 A","Adjustable response value current / li min.":"1 000 A","Adjustable response value current / lr min.":"100 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LI","Switching capacity class of the circuit breaker":"S","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"17 x 6.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"12 x 0"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=399941&mlfb=3VA1010-4ED42-0JA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1010-4ED42-0JA0/alternatives.json"},"ai":{"faq":[{"question":"Does 3VA1010-4ED42-0JA0 include a shunt trip?","answer":"Yes, it ships with a factory-fitted shunt trip release (STL). The integrated auxiliary trip order code is 3VA9688-0BL32."},{"question":"Will 3VA1010-4ED42-0JA0 drop into a panel specified for 3VA1110-5EE32-0JA0?","answer":"Both are 4-pole SENTRON 3VA1 frame breakers with the same 101.6 mm width, so the panel cutout and mounting pattern are identical. The difference is in the release type and rating — the 3VA1110-5EE32-0JA0 carries an electronic trip, while this unit has a fixed TM210 thermal-magnetic release. Mechanically interchangeable, but verify the protection curve and rating match your application."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1010-4ED42-0JA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1010-4ED42-0JA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}