{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1032-2ED32-0BC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1032-2ED32-0BC0","canonicalUrl":"https://aoctrl.com/siemens/3VA1032-2ED32-0BC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1032-2ED32-0BC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1032-2ED32-0BC0, molded case circuit breaker, 3-pole, 32 A rated continuous current (Iu), TM210 thermal-magnetic overcurrent release, 52.5 kA breaking capacity at 240 V, undervoltage release, 2 auxiliary switches HQ, IP40 front.","salesMarkdown":"## SENTRON 3VA1032-2ED32-0BC0 — 32 A MCCB with TM210 Release The Siemens 3VA1032-2ED32-0BC0 is a 3-pole SENTRON molded case circuit breaker (MCCB) rated for 32 A continuous current (Iu) at 40 °C, fitted with a TM210 thermal-magnetic overcurrent release. The breaker carries a 52.5 kA breaking capacity at 240 V, stepping down to 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 690 V, so it handles high available fault current on the low-voltage side of a transformer without needing a current-limiting fuse upstream. No trip indicator on the front, so fault status comes from the auxiliary contacts or the handle position. Above that, the continuous current must be derated: 30.72 A at 55 °C, 30.08 A at 60 °C, 29.44 A at 65 °C, and 28.8 A at 70 °C. Dimensions are 76.2 mm wide, 130 mm high, 70 mm deep — a standard 3-pole MCCB footprint that fits most DIN-rail or panel-mount enclosures.","metaTitle":"Siemens 3VA1032-2ED32-0BC0 SENTRON MCCB, 32 A, 3-Pole, TM210","metaDescription":"Siemens 3VA1032-2ED32-0BC0 SENTRON molded case circuit breaker, 32 A rated continuous current, 3-pole, TM210 thermal-magnetic release, 52.5 kA at 240 V. Current lifecycle stage. Qu","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"52.5 kA","at 415 V":"32 kA","at 440 V":"13.6 kA","at 690 V":"7.5 kA","at 40 °C":"32 A","at 45 °C":"32 A","at 50 °C":"32 A","at 55 °C":"30.72 A","at 60 °C":"30.08 A","at 65 °C":"29.44 A","at 70 °C":"28.8 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"2 auxiliary switches HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"32 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB11","Design of the overcurrent release":"TM210","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"No","Adjustable response value current / Ir max.":"32 A","Adjustable response value current / li max.":"320 A","Adjustable response value current / li min.":"320 A","Adjustable response value current / lr min.":"32 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"2","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching capacity class of the circuit breaker":"B","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"17 x 6.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"12 x 0"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=506214&mlfb=3VA1032-2ED32-0BC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1032-2ED32-0BC0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA1032-2ED32-0BC0?","answer":"Pricing and stock levels are confirmed at quote time. Send an RFQ through this listing, and we'll return current pricing and lead time from our independent distribution network."},{"question":"What is the breaking capacity of 3VA1032-2ED32-0BC0 at different voltages?","answer":"The breaking capacity is 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 690 V. This covers most low-voltage distribution applications from 208 V through 600 V class systems."},{"question":"What does the TM210 release mean on this MCCB?","answer":"TM210 is a thermal-magnetic release where the thermal element is fixed at 32 A (the rated continuous current) and the magnetic short-circuit pickup is adjustable. The '210' typically indicates the frame size and release family within the SENTRON 3VA platform."},{"question":"Does 3VA1032-2ED32-0BC0 include an undervoltage release?","answer":"Yes, it is factory-fitted with an undervoltage release (UVR) that trips the breaker when control voltage drops below a set threshold. It also includes two auxiliary switches (HQ type) for remote status indication."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1032-2ED32-0BC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1032-2ED32-0BC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}