{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1032-2ED36-0AD0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1032-2ED36-0AD0","canonicalUrl":"https://aoctrl.com/siemens/3VA1032-2ED36-0AD0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1032-2ED36-0AD0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON series, molded case circuit breaker (MCCB), 3VA1032-2ED36-0AD0, 3-pole, 32 A rated current, TM210 thermal-magnetic release, breaking capacity 52.5 kA at 240 V.","salesMarkdown":"The Siemens SENTRON 3VA1032-2ED36-0AD0 is a 3-pole molded case circuit breaker (MCCB) rated for 32 A at 40 °C, with a TM210 thermal-magnetic release designed for line protection — meaning it handles overloads and short circuits in distribution panels, motor control centers, or as a main feeder breaker. The 52.5 kA breaking capacity at 240 V gives you headroom on high-fault utility feeds, and it still interrupts 32 kA at 415 V and 13.6 kA at 440 V, so it holds up on 480 V delta systems common in North American plants. This MCCB's interrupting rating drops as system voltage rises: 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at both 500 V and 690 V. The three-pole construction switches all phases simultaneously, so it's suitable for three-phase feeders and motor branch circuits. ## Sizing and thermal performance across temperature The breaker holds its full 32 A rating from 40 °C through 50 °C, then derates to 31 A at 55 °C and 60 °C, and 30 A at 65 °C and 70 °C. The 3VA1032-2ED36-0AD0 measures 130 mm tall, 76.2 mm wide, and 70 mm deep. Width of 76.2 mm (3 inches) is standard for a 3-pole 32 A MCCB — it occupies three 25 mm DIN spaces if mounted on a rail, or bolts directly to a backplate. No undervoltage release or shunt trip is built in (the listing shows no voltage trigger and no undervoltage release), so if you need remote trip, you'll add an external accessory.","metaTitle":"Siemens 3VA1032-2ED36-0AD0 SENTRON MCCB, 32 A, 52.5 kA at 24","metaDescription":"Siemens SENTRON 3VA1032-2ED36-0AD0 molded case circuit breaker, 32 A rated current, 52.5 kA breaking capacity at 240 V, 3-pole, TM210 release. Current production. Available to orde","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"52.5 kA","at 415 V":"32 kA","at 440 V":"13.6 kA","at 500 V":"7.5 kA","at 690 V":"7.5 kA","at 40 °C":"32 A","at 45 °C":"32 A","at 50 °C":"32 A","at 55 °C":"31 A","at 60 °C":"31 A","at 65 °C":"30 A","at 70 °C":"30 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10.6 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA10322ED360AA0","Design Of The Auxiliary Switch":"3 auxiliary switches HQ","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"500 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"3","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching Capacity Class Of The Circuit Breaker":"B","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"box terminal on both sides","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=120759&mlfb=3VA1032-2ED36-0AD0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1032-2ED36-0AD0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA1032-2ED36-0AD0 at 240 V?","answer":"The interrupting rating is 52.5 kA at 240 V. It also carries 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 500 V and 690 V."},{"question":"Where can I buy the 3VA1032-2ED36-0AD0 and get current pricing?","answer":"This part is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — figures are confirmed at quote time."},{"question":"What is the width of 3VA1032-2ED36-0AD0?","answer":"The width is 76.2 mm (3 inches), which is standard for a 3-pole MCCB in this frame size."},{"question":"Does the 3VA1032-2ED36-0AD0 have a shunt trip or undervoltage release?","answer":"No. The listing shows no voltage trigger and no undervoltage release. If remote tripping is needed, an external accessory must be added."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1032-2ED36-0AD0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1032-2ED36-0AD0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}