{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1032-2ED36-0BA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1032-2ED36-0BA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1032-2ED36-0BA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1032-2ED36-0BA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1032-2ED36-0BA0, molded case circuit breaker, 3-pole, 32 A (40 °C), TM210 thermal-magnetic trip, undervoltage release, 52.5 kA at 240 V AC.","salesMarkdown":"Breaking capacity runs from 52.5 kA at 240 V AC down to 7.5 kA at 690 V AC, which covers most commercial and light industrial fault levels. That means if the control voltage drops below its dropout threshold, the breaker trips instantly. Common on safety circuits or upstream of a VFD where you want a guaranteed disconnect on power loss. Power loss is 13.1 W maximum at rated load. In a sealed enclosure with multiple breakers side by side, that heat adds up — account for derating if the ambient inside the panel climbs above 40 °C. The spec table shows the breaker holds 32 A up to 50 °C, then tapers to 30 A at 70 °C, so you've got a 2 A derating window across the upper range.","metaTitle":"Siemens 3VA1032-2ED36-0BA0 SENTRON MCCB, 32A, 3-Pole, 52.5kA","metaDescription":"Siemens SENTRON 3VA1032-2ED36-0BA0 molded case circuit breaker, 32A rated at 40°C, 3-pole, TM210 trip unit, UVR included. Breaking capacity 52.5kA at 240V. Active production, sourc","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"52.5 kA","at 415 V":"32 kA","at 440 V":"13.6 kA","at 500 V":"7.5 kA","at 690 V":"7.5 kA","at 40 °C":"32 A","at 45 °C":"32 A","at 50 °C":"32 A","at 55 °C":"31 A","at 60 °C":"31 A","at 65 °C":"30 A","at 70 °C":"30 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"13.1 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA10322ED360AA0","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB11","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"500 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"B","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"box terminal on both sides","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=78718&mlfb=3VA1032-2ED36-0BA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1032-2ED36-0BA0/alternatives.json"},"ai":{"faq":[{"question":"Does 3VA1032-2ED36-0BA0 include an undervoltage release?","answer":"Yes, this variant includes an undervoltage release (UVR) as the auxiliary release type."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1032-2ED36-0BA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1032-2ED36-0BA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}