{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1032-2ED36-0BC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1032-2ED36-0BC0","canonicalUrl":"https://aoctrl.com/siemens/3VA1032-2ED36-0BC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1032-2ED36-0BC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1032-2ED36-0BC0, Molded case circuit breaker, 3-pole, 32 A, TM210 overcurrent release, 52.5 kA at 240 V, 70 mm depth, undervoltage release included.","salesMarkdown":"## 32 A MCCB with TM210 release and 52.5 kA interrupting capacity Its interrupting capacity hits 52.5 kA at 240 V, stepping down to 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 690 V — so the voltage you feed it directly governs the fault current it can clear. ## Current derating across the operating temperature band This breaker holds full 32 A from 40 °C up through 50 °C. At 55 °C it derates to 30.72 A, then 30.08 A at 60 °C, 29.44 A at 65 °C, and 28.8 A at 70 °C. ## Built-in undervoltage release and auxiliary switches ## Panel fit and mounting dimensions The IP40 front means it's suited for enclosed panel mounting where the front face is behind a door.","metaTitle":"Siemens 3VA1032-2ED36-0BC0 SENTRON MCCB, 32A, 52.5kA at 240V","metaDescription":"Siemens SENTRON 3VA1032-2ED36-0BC0 molded case circuit breaker, 32A rated continuous current, breaking capacity 52.5kA at 240V. Active production, sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"52.5 kA","at 415 V":"32 kA","at 440 V":"13.6 kA","at 690 V":"7.5 kA","at 40 °C":"32 A","at 45 °C":"32 A","at 50 °C":"32 A","at 55 °C":"30.72 A","at 60 °C":"30.08 A","at 65 °C":"29.44 A","at 70 °C":"28.8 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"2 auxiliary switches HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"32 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB11","Design of the overcurrent release":"TM210","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"No","Adjustable response value current / Ir max.":"32 A","Adjustable response value current / li max.":"320 A","Adjustable response value current / li min.":"320 A","Adjustable response value current / lr min.":"32 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"2","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching capacity class of the circuit breaker":"B","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (1.5 - 70 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=100021&mlfb=3VA1032-2ED36-0BC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1032-2ED36-0BC0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA1032-2ED36-0BC0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is 3VA1032-2ED36-0BC0's interrupting capacity at different voltages?","answer":"At 240 V it clears 52.5 kA, at 415 V it clears 32 kA, at 440 V it clears 13.6 kA, and at 690 V it clears 7.5 kA."},{"question":"Will 3VA1032-2ED36-0BC0 drop into a panel specified around 3VA1010-2ED36-0AC0 without rewiring?","answer":"Yes — both share the same 76.2 mm width and SENTRON 3VA frame, so the 32 A unit mounts into the same panel cutout and bus bar layout as the 3VA1010 frame breakers."},{"question":"What compliance documentation does Siemens provide for 3VA1032-2ED36-0BC0?","answer":"As a SENTRON MCCB it carries standard IEC/EN 60947-2 certification and UL recognition. RoHS and REACH compliance documentation is available from Siemens upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1032-2ED36-0BC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1032-2ED36-0BC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}