{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1032-2ED36-0DA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1032-2ED36-0DA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1032-2ED36-0DA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1032-2ED36-0DA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1032-2ED36-0DA0, molded case circuit breaker, 3-pole, 32 A, line protection, TM210 thermal-magnetic release, breaking capacity 52.5 kA at 240 V.","salesMarkdown":"## MCCB for distribution panels — 32 A, 3-pole, line protection Breaking capacity climbs with lower system voltage: 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 690 V. At 415 V — common in industrial distribution — that 32 kA SCCR gives headroom for most low-voltage switchgear lineups without cascading upstream. ## Thermal derating — what the 32 A means at panel ambient At 55 °C it drops to 30.72 A, at 60 °C to 30.08 A, at 65 °C to 29.44 A, and at 70 °C to 28.8 A. The integrated auxiliary trip accessory is order code 3VA9608-0BB25 if you need to add a shunt trip later. That's not a motor-starting contactor rating; if your application cycles the breaker weekly, consider a contactor in series.","metaTitle":"Siemens 3VA1032-2ED36-0DA0 SENTRON MCCB, 32 A, 3-Pole, Line","metaDescription":"Siemens SENTRON 3VA1032-2ED36-0DA0 molded case circuit breaker, 32 A rated continuous current, 3-pole, line protection, TM210 release. Breaking capacity 52.5 kA at 240 V. Current p","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"52.5 kA","at 415 V":"32 kA","at 440 V":"13.6 kA","at 690 V":"7.5 kA","at 40 °C":"32 A","at 45 °C":"32 A","at 50 °C":"32 A","at 55 °C":"30.72 A","at 60 °C":"30.08 A","at 65 °C":"29.44 A","at 70 °C":"28.8 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"32 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB25","Design of the overcurrent release":"TM210","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"No","Adjustable response value current / Ir max.":"32 A","Adjustable response value current / li max.":"320 A","Adjustable response value current / li min.":"320 A","Adjustable response value current / lr min.":"32 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LI","Switching capacity class of the circuit breaker":"B","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (1.5 - 70 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=531084&mlfb=3VA1032-2ED36-0DA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1032-2ED36-0DA0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA1032-2ED36-0DA0?","answer":"Submit an RFQ against your BOM line; we source this through independent distribution and confirm current pricing and factory lead time at quote."},{"question":"What is the breaking capacity of 3VA1032-2ED36-0DA0 at 415 V?","answer":"32 kA at 415 V, which covers most industrial low-voltage switchgear lineups without needing upstream current-limiting fuses."},{"question":"Does 3VA1032-2ED36-0DA0 include an undervoltage release?","answer":"Yes, the undervoltage release (UVR) is standard — the auxiliary release design is built in."},{"question":"Will 3VA1032-2ED36-0DA0 drop into a panel specified around 3VA1010-2ED42-0AE0?","answer":"The 3VA1032-2ED36-0DA0 shares the same SENTRON 3VA frame family, so physical footprint and mounting are identical. The difference is rating: this unit is 32 A with a TM210 release versus the 3VA1010-2ED42-0AE0's different amp rating and release variant. No rewiring needed if the bus and lug sizes match the higher current."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1032-2ED36-0DA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1032-2ED36-0DA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}