{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1032-2ED36-0DH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1032-2ED36-0DH0","canonicalUrl":"https://aoctrl.com/siemens/3VA1032-2ED36-0DH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1032-2ED36-0DH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1032-2ED36-0DH0, 3-pole molded case circuit breaker, 32 A rated continuous current Iu, TM210 thermal-magnetic release, 52.5 kA interrupting at 240 V, undervoltage release, IP40 front protection.","salesMarkdown":"The interrupting ratings climb to 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 690 V — so at 415 V it clears faults up to 32 kA, which covers most industrial distribution panels downstream of a transformer. Above that it derates linearly: 30.72 A at 55 °C, 30.08 A at 60 °C, 29.44 A at 65 °C, and 28.8 A at 70 °C. If the panel ambient runs at 60 °C, plan for 30 A continuous — not the full 32 A. The enclosure footprint is 76.2 mm wide by 130 mm tall by 70 mm deep, which fits a standard 3-pole MCCB slot on a DIN rail or panel-mount base. This variant ships with an integrated undervoltage release (UVR) — the coil drops the breaker if control voltage falls below the dropout threshold, which is standard for emergency-stop or undervoltage protection schemes. The trip indicator on the front confirms a fault trip visually. The auxiliary release order code for replacement is 3VA9608-0BB25.","metaTitle":"Siemens 3VA1032-2ED36-0DH0 SENTRON MCCB, 32 A, 52.5 kA","metaDescription":"Siemens SENTRON 3VA1032-2ED36-0DH0 molded case circuit breaker, 3-pole, 32 A rated, 52.5 kA at 240 V. TM210 release, undervoltage release, IP40 front. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"52.5 kA","at 415 V":"32 kA","at 440 V":"13.6 kA","at 690 V":"7.5 kA","at 40 °C":"32 A","at 45 °C":"32 A","at 50 °C":"32 A","at 55 °C":"30.72 A","at 60 °C":"30.08 A","at 65 °C":"29.44 A","at 70 °C":"28.8 A","Trip indicator":"Yes","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"32 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB25","Design of the overcurrent release":"TM210","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"No","Adjustable response value current / Ir max.":"32 A","Adjustable response value current / li max.":"320 A","Adjustable response value current / li min.":"320 A","Adjustable response value current / lr min.":"32 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"3","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching capacity class of the circuit breaker":"B","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (1.5 - 70 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=219709&mlfb=3VA1032-2ED36-0DH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1032-2ED36-0DH0/alternatives.json"},"ai":{"faq":[{"question":"What is the interrupting rating of 3VA1032-2ED36-0DH0 at 415 V?","answer":"32 kA at 415 V. The breaker also carries 52.5 kA at 240 V, 13.6 kA at 440 V, and 7.5 kA at 690 V."},{"question":"What auxiliary contacts does this MCCB include?","answer":"It includes 2 auxiliary switches plus 1 trip alarm switch (HQ configuration). The auxiliary release replacement order code is 3VA9608-0BB25."},{"question":"Where can I buy 3VA1032-2ED36-0DH0 and how is it quoted?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — no stock or price figures are published here."},{"question":"What is the ambient temperature derating for this breaker?","answer":"The 32 A rating holds from 40 °C to 50 °C. At 55 °C it derates to 30.72 A, at 60 °C to 30.08 A, at 65 °C to 29.44 A, and at 70 °C to 28.8 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1032-2ED36-0DH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1032-2ED36-0DH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}