{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1032-2ED36-0JH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1032-2ED36-0JH0","canonicalUrl":"https://aoctrl.com/siemens/3VA1032-2ED36-0JH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1032-2ED36-0JH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1032-2ED36-0JH0, molded case circuit breaker, 3-pole, 32 A rated (40 °C), breaking capacity 52.5 kA at 240 V AC, line protection design.","salesMarkdown":"This MCCB delivers 52.5 kA breaking capacity at 240 V AC, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at both 500 V and 690 V. The 52.5 kA figure at 240 V is high enough for most secondary distribution panels fed from a large transformer; the 32 kA at 415 V covers standard European low-voltage mains. At 690 V the 7.5 kA rating limits its use to systems with relatively low available fault current — check your point-of-installation SCCR before specifying. ## Thermal derating — how ambient temperature affects the continuous current Rated 32 A from 40 °C through 50 °C ambient, it derates to 31 A at 55 °C and 60 °C, and to 30 A at 65 °C and 70 °C. ## Auxiliary and release options built in The basic switch assembly carries order code 3VA10322ED360AA0. Dimensions: 130 mm high, 76.2 mm wide, 70 mm deep — a standard 3-pole MCCB footprint for DIN-rail or panel-mount installation.","metaTitle":"Siemens 3VA1032-2ED36-0JH0 SENTRON MCCB, 32A, 3-Pole, 52.5kA","metaDescription":"Siemens SENTRON 3VA1032-2ED36-0JH0 molded case circuit breaker, 32A rated, 3-pole, 52.5kA breaking at 240V. Active production. Sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"52.5 kA","at 415 V":"32 kA","at 440 V":"13.6 kA","at 500 V":"7.5 kA","at 690 V":"7.5 kA","at 40 °C":"32 A","at 45 °C":"32 A","at 50 °C":"32 A","at 55 °C":"31 A","at 60 °C":"31 A","at 65 °C":"30 A","at 70 °C":"30 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10.6 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA10322ED360AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL32","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"500 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"3","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching Capacity Class Of The Circuit Breaker":"B","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"box terminal on both sides","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=367021&mlfb=3VA1032-2ED36-0JH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1032-2ED36-0JH0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA1032-2ED36-0JH0 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of 3VA1032-2ED36-0JH0 at different voltages?","answer":"52.5 kA at 240 V AC, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at both 500 V and 690 V."},{"question":"Does the 3VA1032-2ED36-0JH0 include auxiliary switches or a shunt trip?","answer":"Yes, it comes with 2 auxiliary switches plus 1 trip alarm switch (HQ), and a shunt trip release (STL) for remote tripping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1032-2ED36-0JH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1032-2ED36-0JH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}