{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1032-3ED36-0HA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1032-3ED36-0HA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1032-3ED36-0HA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1032-3ED36-0HA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1032-3ED36-0HA0, molded case circuit breaker, 3-pole, 32 A rated continuous current Iu, line protection version, breaking capacities 75.6 kA at 240 V / 52.5 kA at 415 V / 32 kA at 440 V / 7.5 kA at 690 V, TM210 thermal-magnetic release, shunt trip (STL) auxiliary release, IP40 front protection.","salesMarkdown":"Its breaking capacity ranges from 75.6 kA at 240 V down to 7.5 kA at 690 V, so the same frame covers high-fault panels at lower voltages and still interrupts a 7.5 kA fault on a 690 V line — useful when a single MCCB type must be specified across a mixed-voltage plant. The TM210 overcurrent release is a thermal-magnetic trip unit — the thermal element handles overloads with an inverse-time curve, the magnetic element snaps on short-circuit. ## Temperature derating — the real current you get Above that, the continuous current must be reduced: 30.72 A at 55 °C, 30.08 A at 60 °C, 29.44 A at 65 °C, and 28.8 A at 70 °C. The storage limit is wider because the breaker isn't carrying current — that's the handling limit, not the running limit. Front protection is IP40 — splash-resistant from the front, but the terminals and sides are not sealed. Mount it inside a panel with at least IP54 enclosure if washdown or dust is present. ## Auxiliary release and accessories The specific accessory order code for the integrated shunt trip is 3VA9688-0BL30. No undervoltage release, no auxiliary contacts, no communication module are fitted on this variant. If you need remote status feedback or undervoltage protection, you'd order a different 3VA configuration or add external aux contacts separately.","metaTitle":"Siemens 3VA1032-3ED36-0HA0 SENTRON MCCB, 32 A, 3-Pole, 75.6","metaDescription":"Siemens SENTRON 3VA1032-3ED36-0HA0 molded case circuit breaker, 32 A rated, 3-pole, line protection. Breaking capacity 75.6 kA at 240 V. Active production, sourced to order. Reques","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"75.6 kA","at 415 V":"52.5 kA","at 440 V":"32 kA","at 690 V":"7.5 kA","at 40 °C":"32 A","at 45 °C":"32 A","at 50 °C":"32 A","at 55 °C":"30.72 A","at 60 °C":"30.08 A","at 65 °C":"29.44 A","at 70 °C":"28.8 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"32 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL30","Design of the overcurrent release":"TM210","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"No","Adjustable response value current / Ir max.":"32 A","Adjustable response value current / li max.":"320 A","Adjustable response value current / li min.":"320 A","Adjustable response value current / lr min.":"32 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LI","Switching capacity class of the circuit breaker":"N","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (1.5 - 70 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=308728&mlfb=3VA1032-3ED36-0HA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1032-3ED36-0HA0/alternatives.json"},"ai":{"faq":[{"question":"What is 3VA1032-3ED36-0HA0's listed depth on this component line?","answer":"The depth is 70 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1032-3ED36-0HA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1032-3ED36-0HA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}