{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1063-2ED36-0HA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1063-2ED36-0HA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1063-2ED36-0HA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1063-2ED36-0HA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1063-2ED36-0HA0, molded case circuit breaker, 3-pole, 63 A rated at 40 °C, breaking capacity 52.5 kA at 240 V, line protection with TM210 release and shunt trip.","salesMarkdown":"## MCCB for line protection with shunt trip It carries a 63 A rating at 40 °C and a rated insulation voltage of 800 V, with a TM210 thermal-magnetic overcurrent release and an integrated shunt trip (STL) auxiliary release for remote tripping. Breaking capacity reaches 52.5 kA at 240 V AC and 32 kA at 415 V AC, giving it solid fault-interruption headroom for industrial main or subfeed applications where high available fault current is expected. The breaker holds its full 63 A rating up to 50 °C, then derates gradually to 58 A at 70 °C. Operating ambient range is -25 °C to +70 °C; storage range is -40 °C to +80 °C. Maximum power loss is 17.3 W. ## Integration and physical fit Dimensions are 130 mm height, 76.2 mm width, 70 mm depth. The 3-pole footprint fits standard panel-mount cutouts for SENTRON 3VA breakers. No communication function or undervoltage release is included; the shunt trip is factory-fitted.","metaTitle":"Siemens 3VA1063-2ED36-0HA0 SENTRON MCCB, 63A, 52.5kA at 240V","metaDescription":"Siemens SENTRON 3VA1063-2ED36-0HA0 molded case circuit breaker, 3-pole, 63A rated at 40°C, 52.5kA breaking at 240V. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"52.5 kA","at 415 V":"32 kA","at 440 V":"13.6 kA","at 500 V":"7.5 kA","at 690 V":"7.5 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"62 A","at 60 °C":"61 A","at 65 °C":"60 A","at 70 °C":"58 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"17.3 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA10632ED360AA0","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL30","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"500 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"B","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"box terminal on both sides","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=18920&mlfb=3VA1063-2ED36-0HA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1063-2ED36-0HA0/alternatives.json"},"ai":{"faq":[{"question":"How do I get pricing and availability for 3VA1063-2ED36-0HA0?","answer":"Submit an RFQ through this listing. The part is sourced to order; current pricing and stock status are confirmed at quote time."},{"question":"What is the breaking capacity of 3VA1063-2ED36-0HA0 at 415 V?","answer":"The breaking capacity at 415 V AC is 32 kA, with higher ratings at lower voltages (52.5 kA at 240 V) and lower ratings at higher voltages (7.5 kA at 690 V)."},{"question":"Does 3VA1063-2ED36-0HA0 include a shunt trip?","answer":"Yes, it is equipped with a shunt trip (STL) auxiliary release for remote tripping. It does not include an undervoltage release."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1063-2ED36-0HA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1063-2ED36-0HA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}