{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1063-3ED32-0CC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1063-3ED32-0CC0","canonicalUrl":"https://aoctrl.com/siemens/3VA1063-3ED32-0CC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1063-3ED32-0CC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1063-3ED32-0CC0, molded case circuit breaker (MCCB), 3-pole, 63 A rated continuous current, TM210 thermal-magnetic overcurrent release, 75.6 kA breaking capacity at 240 V AC, undervoltage release, 2 auxiliary switches HQ, IP40 front.","salesMarkdown":"The Siemens 3VA1063-3ED32-0CC0 is a 3-pole SENTRON molded case circuit breaker (MCCB) rated for 63 A continuous current at 40 °C, with a TM210 thermal-magnetic overcurrent release. This breaker carries 75.6 kA breaking capacity at 240 V AC, 52.5 kA at 415 V, and 32 kA at 440 V — figures that tell you it can interrupt fault currents up to those levels without upstream coordination failure. The auxiliary contacts are wired separately from the main power path, so they report the breaker's actual mechanical position, not just the trip signal. It mounts on a DIN rail or panel-mount baseplate, occupying 76.2 mm width (roughly 4.5 standard module spaces) and 130 mm height. Above 50 °C, the breaker must be derated: 60.48 A at 55 °C, 59.22 A at 60 °C, 57.96 A at 65 °C, and 56.7 A at 70 °C. If your panel runs hot — near a drive cabinet or in a non-climate-controlled enclosure — use the 55 °C or 60 °C column to size the breaker.","metaTitle":"Siemens 3VA1063-3ED32-0CC0 SENTRON MCCB, 63 A, TM210, 75.6 k","metaDescription":"Siemens 3VA1063-3ED32-0CC0 SENTRON molded case circuit breaker, 63 A rated at 40 °C, TM210 thermal-magnetic release, 75.6 kA at 240 V. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"75.6 kA","at 415 V":"52.5 kA","at 440 V":"32 kA","at 690 V":"7.5 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"60.48 A","at 60 °C":"59.22 A","at 65 °C":"57.96 A","at 70 °C":"56.7 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"2 auxiliary switches HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"63 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB24","Design of the overcurrent release":"TM210","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"No","Adjustable response value current / Ir max.":"63 A","Adjustable response value current / li max.":"630 A","Adjustable response value current / li min.":"630 A","Adjustable response value current / lr min.":"63 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"2","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching capacity class of the circuit breaker":"N","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"17 x 6.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"12 x 0"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=358572&mlfb=3VA1063-3ED32-0CC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1063-3ED32-0CC0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA1063-3ED32-0CC0 at different voltages?","answer":"75.6 kA at 240 V AC, 52.5 kA at 415 V AC, 32 kA at 440 V AC, and 7.5 kA at 690 V AC."},{"question":"What does the TM210 release mean on this MCCB?","answer":"TM210 is a thermal-magnetic release where the thermal element is fixed at the frame rating (63 A) and the magnetic short-circuit pickup is adjustable, typically between 5× and 10× In. The exact adjustment range should be verified from the device manual."},{"question":"Does 3VA1063-3ED32-0CC0 include an undervoltage release?","answer":"Yes, it comes with an integrated undervoltage release (UVR) as standard, plus two auxiliary switches (HQ type) for status signaling."},{"question":"Where can I buy 3VA1063-3ED32-0CC0 and what is the lead time?","answer":"This MCCB is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or lead-time number is published here."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1063-3ED32-0CC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1063-3ED32-0CC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}