{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1063-3ED36-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1063-3ED36-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1063-3ED36-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1063-3ED36-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1063-3ED36-0AA0, molded case circuit breaker, 3-pole, 63 A (40 °C), TM210 release, line protection, IP40 front, depth 70 mm, width 76.2 mm, height 130 mm.","salesMarkdown":"The Siemens SENTRON 3VA1063-3ED36-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated 63 A at 40 °C, fitted with a TM210 thermal-magnetic overcurrent release and designed for line protection in distribution panels. Its interrupting capacity reaches 75.6 kA at 240 V and 52.5 kA at 415 V, with a derated curve down to 7.5 kA at 690 V — covering most industrial low-voltage fault levels without requiring an upstream current-limiting fuse. The 63 A rating holds flat from 40 °C to 50 °C, then steps down to 62 A at 55 °C, 61 A at 60 °C, 60 A at 65 °C, and 58 A at 70 °C. In a sealed, uncooled enclosure — common in automotive Tier-1 panel builds — the 55 °C derate to 62 A is the practical limit for a continuous 60 A load. The maximum power loss is 17.3 W, which factors into the enclosure thermal rise calculation. The breaker occupies 70 mm depth, 76.2 mm width (3 in), and 130 mm height (5.12 in). Three-pole construction with a screw-clamp termination pattern standard for SENTRON 3VA frames.","metaTitle":"Siemens 3VA1063-3ED36-0AA0 SENTRON MCCB, 63 A, 3-Pole, 70 mm","metaDescription":"Siemens SENTRON 3VA1063-3ED36-0AA0 molded case circuit breaker, 63 A rated at 40 °C, 3-pole, TM210 release. Interrupting capacity 75.6 kA at 240 V. Active production. Sourced to or","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","title":"3VA1063-3ED36-0AA0","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"75.6 kA","at 415 V":"52.5 kA","at 440 V":"32 kA","at 500 V":"7.5 kA","at 690 V":"7.5 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"62 A","at 60 °C":"61 A","at 65 °C":"60 A","at 70 °C":"58 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","description":"circuit breaker 3VA1 IEC frame 100 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM210, FTFM, In=63A overload protection Ir=63A fixed short-circuit protection Ii=10 x In clamp connection","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"17.3 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"500 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"N","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"box terminal on both sides","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/195a416c7bbda069d98ea5c58764fd71.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=15601&mlfb=3VA1063-3ED36-0AA0"},"ai":{"faq":[{"question":"What is the interrupting capacity of 3VA1063-3ED36-0AA0 at different voltages?","answer":"75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at both 500 V and 690 V. These ratings cover most industrial low-voltage fault levels without requiring an upstream current-limiting fuse."},{"question":"What is the depth of 3VA1063-3ED36-0AA0?","answer":"70 mm (2.76 in). Width is 76.2 mm (3 in) and height is 130 mm (5.12 in)."},{"question":"Where can I buy 3VA1063-3ED36-0AA0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1063-3ED36-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1063-3ED36-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}