{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1063-3ED36-0AF0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1063-3ED36-0AF0","canonicalUrl":"https://aoctrl.com/siemens/3VA1063-3ED36-0AF0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1063-3ED36-0AF0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1063-3ED36-0AF0, 3-pole molded case circuit breaker, 63 A at 40 °C, 75.6 kA interrupting at 240 V, TM210 thermal-magnetic release, line protection design.","salesMarkdown":"## 63 A MCCB with 75.6 kA interrupting capacity — line protection for distribution panels The Siemens SENTRON 3VA1063-3ED36-0AF0 is a 3-pole molded case circuit breaker (MCCB) rated for 63 A continuous at 40 °C, with a thermal-magnetic TM210 release designed for line protection in distribution panels. It interrupts fault currents up to 75.6 kA at 240 V, 52.5 kA at 415 V, and 32 kA at 440 V — covering the typical fault-current range for commercial and light industrial feeder circuits. Rated current holds at 63 A from 40 °C through 50 °C, then tapers to 58 A at 70 °C — a thermal curve that matches the typical panel ambient. ## Interrupting ratings and trip indication — what they mean for fault coordination The built-in trip indicator gives a visual flag when the breaker has opened on fault, speeding fault isolation on a multi-breaker panel. ## Lifecycle and sourcing — current production, quoted to order This 3VA1063-3ED36-0AF0 carries a lifecycle status of current production, meaning it remains an active catalog line from Siemens. No last-time-buy or phase-out notice is on record. ## Panel integration — DIN-rail mount, auxiliary switch provision The 130 mm height leaves clearance for busbar connections in a standard enclosure.","metaTitle":"Siemens 3VA1063-3ED36-0AF0 SENTRON MCCB, 63A, 75.6kA","metaDescription":"Siemens SENTRON 3VA1063-3ED36-0AF0 molded case circuit breaker, 63A at 40°C, 75.6kA interrupting at 240V. 3-pole, line protection, TM210 release. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","title":"3VA1063-3ED36-0AF0","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"75.6 kA","at 415 V":"52.5 kA","at 440 V":"32 kA","at 500 V":"7.5 kA","at 690 V":"7.5 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"62 A","at 60 °C":"61 A","at 65 °C":"60 A","at 70 °C":"58 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","description":"circuit breaker 3VA1 IEC frame 100 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM210, FTFM, In=63A overload protection Ir=63A fixed short-circuit protection Ii=10 x In clamp connection 1 auxiliary switch HQ 1 trip alarm switch HQ","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"17.3 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA10633ED360AA0","Design Of The Auxiliary Switch":"1 auxiliary switch + 1 trip alarm switch HQ","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"500 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"2","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching Capacity Class Of The Circuit Breaker":"N","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"box terminal on both sides","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d2e83723de40278c6cb50cdcfd28247c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=509904&mlfb=3VA1063-3ED36-0AF0"},"ai":{"faq":[{"question":"Does 3VA1063-3ED36-0AF0 include auxiliary switches?","answer":"Yes, it comes with 1 auxiliary switch + 1 trip alarm switch HQ for remote status and fault indication."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1063-3ED36-0AF0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1063-3ED36-0AF0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}