{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1080-3ED42-0JH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1080-3ED42-0JH0","canonicalUrl":"https://aoctrl.com/siemens/3VA1080-3ED42-0JH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1080-3ED42-0JH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1080-3ED42-0JH0, molded case circuit breaker, 4-pole, 80 A rated continuous current Iu, breaking capacity 75.6 kA at 240 V, TM210 overcurrent release, shunt trip, IP40 front.","salesMarkdown":"## SENTRON 3VA1080-3ED42-0JH0 — 80 A MCCB with TM210 release and shunt trip The integrated shunt trip (STL) allows remote tripping via a control signal, useful for emergency-stop or supervisory shutdown circuits. Breaking capacity varies sharply with system voltage: 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at 690 V. Thermal derating is minimal up to 50 °C — the breaker carries the full 80 A at 40, 45, and 50 °C. Above that it steps down: 76.8 A at 55 °C, 75.2 A at 60 °C, 73.6 A at 65 °C, and 72 A at 70 °C. In a hot panel near drives or transformers, that 72 A at 70 °C is the real-world limit, not the nameplate 80 A. ## Physical integration and auxiliary wiring Dimensions: 130 mm height, 101.6 mm width, 70 mm depth.","metaTitle":"Siemens 3VA1080-3ED42-0JH0 SENTRON MCCB, 80 A, 4-Pole, 75.6","metaDescription":"Siemens SENTRON 3VA1080-3ED42-0JH0 molded case circuit breaker, 80 A rated, 4-pole, 75.6 kA breaking at 240 V. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"101.6 mm","Height":"130 mm","at 240 V":"75.6 kA","at 415 V":"52.5 kA","at 440 V":"32 kA","at 690 V":"7.5 kA","at 40 °C":"80 A","at 45 °C":"80 A","at 50 °C":"80 A","at 55 °C":"76.8 A","at 60 °C":"75.2 A","at 65 °C":"73.6 A","at 70 °C":"72 A","Trip indicator":"Yes","Number of poles":"4","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"80 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL32","Design of the overcurrent release":"TM210","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Design of the N-conductor protection":"Without","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"600 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"No","Adjustable response value current / Ir max.":"80 A","Adjustable response value current / li max.":"800 A","Adjustable response value current / li min.":"800 A","Adjustable response value current / lr min.":"80 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"3","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching capacity class of the circuit breaker":"N","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"17 x 6.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"12 x 0"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=183694&mlfb=3VA1080-3ED42-0JH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1080-3ED42-0JH0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the 3VA1080-3ED42-0JH0 at 415 V?","answer":"52.5 kA at 415 V. At 240 V it is 75.6 kA, at 440 V it is 32 kA, and at 690 V it is 7.5 kA."},{"question":"What type of overcurrent release does this MCCB use?","answer":"It uses a TM210 thermal-magnetic release — fixed thermal and magnetic trip settings, no field adjustment."},{"question":"Does the 3VA1080-3ED42-0JH0 include a shunt trip?","answer":"Yes, it is equipped with a shunt trip (STL) for remote tripping via a control voltage signal."},{"question":"Where can I buy the 3VA1080-3ED42-0JH0 and what is the lead time?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time and price."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1080-3ED42-0JH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1080-3ED42-0JH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}