{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1080-4ED36-0DC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1080-4ED36-0DC0","canonicalUrl":"https://aoctrl.com/siemens/3VA1080-4ED36-0DC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1080-4ED36-0DC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1080-4ED36-0DC0, 3-pole molded case circuit breaker, 80 A rated continuous current, TM210 thermal-magnetic release, 121 kA interrupting at 240 V, with undervoltage release and 2 HQ auxiliary switches.","salesMarkdown":"## Line protection MCCB, 80 A frame, TM210 release The Siemens SENTRON 3VA1080-4ED36-0DC0 is a 3-pole molded case circuit breaker (MCCB) rated for 80 A continuous current at 40 °C, with the TM210 thermal-magnetic overcurrent release. It holds the full 80 A up to 50 °C — no derating needed in a typical warm panel — then steps down to 76.8 A at 55 °C, 75.2 A at 60 °C, 73.6 A at 65 °C, and 72 A at 70 °C. That thermal curve means if your enclosure runs hot, you lose less than 10 % of capacity even at the upper operating limit. ## Interrupting capacity across voltage tiers Breaking capacity is voltage-dependent: 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at 690 V. That 121 kA at 240 V covers high-fault utility feeds; the 11.9 kA at 690 V still clears most industrial motor-circuit faults. ## Undervoltage release and auxiliary contacts Two HQ auxiliary switches (form C) are integrated for remote status feedback. The auxiliary trip accessory is order code 3VA9608-0BB25 if you need to add a shunt trip later. Mechanical endurance rated at 15 000 cycles, which is typical for a distribution MCCB in a panel that sees infrequent switching.","metaTitle":"Siemens 3VA1080-4ED36-0DC0 SENTRON MCCB, 80 A, 3-Pole, 121 k","metaDescription":"Siemens 3VA1080-4ED36-0DC0 SENTRON molded case circuit breaker, 80 A rated, 3-pole, 121 kA at 240 V. TM210 release, undervoltage trip. Current production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"121 kA","at 415 V":"75.6 kA","at 440 V":"52.5 kA","at 690 V":"11.9 kA","at 40 °C":"80 A","at 45 °C":"80 A","at 50 °C":"80 A","at 55 °C":"76.8 A","at 60 °C":"75.2 A","at 65 °C":"73.6 A","at 70 °C":"72 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"2 auxiliary switches HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"80 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB25","Design of the overcurrent release":"TM210","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"No","Adjustable response value current / Ir max.":"80 A","Adjustable response value current / li max.":"800 A","Adjustable response value current / li min.":"800 A","Adjustable response value current / lr min.":"80 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"2","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching capacity class of the circuit breaker":"S","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (1.5 - 70 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=400559&mlfb=3VA1080-4ED36-0DC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1080-4ED36-0DC0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA1080-4ED36-0DC0 and how is it quoted?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — no stock figures or lead-time numbers are published here."},{"question":"What is the interrupting capacity of 3VA1080-4ED36-0DC0 at 415 V?","answer":"75.6 kA at 415 V. At 240 V it is 121 kA, at 440 V it is 52.5 kA, and at 690 V it is 11.9 kA."},{"question":"Does 3VA1080-4ED36-0DC0 include an undervoltage release?","answer":"Yes, it ships with an undervoltage release (UVR) fitted. It also includes two HQ auxiliary switches for remote status feedback."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1080-4ED36-0DC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1080-4ED36-0DC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}