{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1096-2ED32-0AA0-ZD00","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1096-2ED32-0AA0-ZD00","canonicalUrl":"https://aoctrl.com/siemens/3VA1096-2ED32-0AA0-ZD00","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1096-2ED32-0AA0-ZD00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3VA1 IEC frame 100 circuit breaker, 3-pole, 16 A, breaking capacity class B Icu=16 kA @ 415 V, TM210 line protection, fixed thermal and short-circuit settings.","salesMarkdown":"The Siemens 3VA1096-2ED32-0AA0-ZD00 is a 3-pole IEC frame 100 circuit breaker rated 16 A continuous, with a breaking capacity of 16 kA Icu at 415 V (class B). It uses a TM210 thermal-magnetic trip unit — fixed overload protection at Ir=16 A and fixed short-circuit protection at Ii=20 x In (320 A). The 'FTFM' designation indicates fixed thermal, fixed magnetic settings, meaning no field-adjustable dials; what you order is what protects the circuit. For a 400 V distribution board with a prospective short-circuit current under 16 kA, this breaker clears the fault without upstream coordination issues. The fixed Ii=20 x In (320 A) means magnetic trips only on high-impedance faults — suitable for motor or transformer branch circuits where inrush must ride through without nuisance tripping. The TM210 thermal curve provides inverse-time overload protection for cable and equipment. ## Deployment context The nut keeper kit (included per the order code suffix) secures the breaker against vibration in OEM equipment — useful for DC Power OEM installations in China, as noted in the spec. The 3VA1 frame is compact enough for high-density panel layouts, but the fixed trip settings mean you cannot dial down the Ir; the 16 A rating must match the load cable ampacity exactly.","metaTitle":"Siemens 3VA1096-2ED32-0AA0-ZD00 Circuit Breaker, 16A, 16kA @","metaDescription":"Siemens 3VA1096-2ED32-0AA0-ZD00 circuit breaker, IEC frame 100, 3-pole, 16A, 16kA Icu @ 415V. Current lifecycle stage. Sourced to order — request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"title":"3VA1096-2ED32-0AA0-ZD00","description":"circuit breaker 3VA1 IEC frame 100 breaking capacity class B Icu=16kA @ 415V 3-pole, line protection TM210, FTFM, In=16A overload protection Ir=16A fixed short-circuit protection Ii=20 x In nut keeper kit for DC Power OEM in China","lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/54216e38b9e90b33e60175b551b22fcd.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1667501&mlfb=3VA1096-2ED32-0AA0-ZD00"},"ai":{"faq":[{"question":"What is the breaking capacity of this breaker?","answer":"The ultimate breaking capacity (Icu) is 16 kA at 415 V, class B per IEC 60947-2."},{"question":"Where can I buy 3VA1096-2ED32-0AA0-ZD00?","answer":"This part is sourced to order through independent distribution. Submit an RFQ for current availability and pricing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1096-2ED32-0AA0-ZD00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1096-2ED32-0AA0-ZD00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}