{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1096-2ED32-0HA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1096-2ED32-0HA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1096-2ED32-0HA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1096-2ED32-0HA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3VA1 IEC frame 100 circuit breaker, breaking capacity class B, Icu=16kA @ 415V, 3-pole, line protection TM210, FTFM, In=16A, shunt trip (STL) 12-30V DC / 24V AC.","salesMarkdown":"## Siemens 3VA1096-2ED32-0HA0 — 16A IEC Frame 100 Circuit Breaker with Shunt Trip The Siemens 3VA1096-2ED32-0HA0 is a 3-pole IEC frame 100 circuit breaker rated at In=16A with a breaking capacity Icu=16kA at 415V, placing it in breaking capacity class B for high-fault industrial panels. It carries a fixed thermal overload protection set at Ir=16A and a fixed short-circuit protection at Ii=10 x In, meaning the magnetic trip fires at 160A — a setting sized for motor branch circuits or feeder protection where the inrush stays under that multiple. The integrated shunt trip (STL) operates on 12-30V DC or 24V AC 50/60Hz, allowing remote tripping from a safety relay or emergency-stop circuit without a separate undervoltage release module. ## Deployment Context — Panel Integration The nut keeper kit (included) retains the terminal screws during wiring — a time-saver on repetitive builds. The FTFM (Fixed Thermal Fixed Magnetic) trip unit means no adjustment dials: Ir and Ii are factory-set. For a BOM freeze, this eliminates calibration drift or field mis-setting on a 16A branch. For a BOM line requiring a 16A IEC breaker with shunt trip capability, this part is specifiable today through normal supply.","metaTitle":"Siemens 3VA1096-2ED32-0HA0 Circuit Breaker, 16A, 16kA @ 415V","metaDescription":"Siemens 3VA1096-2ED32-0HA0 IEC frame 100 circuit breaker, 16A, 16kA breaking capacity @ 415V, shunt trip, current production. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=462387&mlfb=3VA1096-2ED32-0HA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1096-2ED32-0HA0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA1096-2ED32-0HA0?","answer":"The breaking capacity is Icu=16kA at 415V, which places it in IEC breaking capacity class B for industrial duty."},{"question":"What voltage does the shunt trip on 3VA1096-2ED32-0HA0 require?","answer":"The shunt trip operates on 12-30V DC or 24V AC 50/60Hz, compatible with common safety relay outputs and PLC digital outputs."},{"question":"Where can I buy 3VA1096-2ED32-0HA0?","answer":"This part is sourced to order against an RFQ through independent distribution. Current availability and pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1096-2ED32-0HA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1096-2ED32-0HA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}