{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1096-3ED32-0DA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1096-3ED32-0DA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1096-3ED32-0DA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1096-3ED32-0DA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1096-3ED32-0DA0, molded case circuit breaker, 3-pole, 16 A, breaking capacity 75.6 kA at 240 V AC, line protection design with TM210 overcurrent release.","salesMarkdown":"The Siemens SENTRON 3VA1096-3ED32-0DA0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, with a continuous current of 16 A up to 55 °C and 15 A at 70 °C. Breaking capacity drops to 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at 500 V and 690 V — the standard derating curve for a 16 A frame. The 3VA1096-3ED32-0DA0 measures 70 mm deep, 76.2 mm wide, and 130 mm tall — a standard 3-pole MCCB footprint that fits most DIN-rail or panel-mount enclosures without re-drilling. Power loss is 13.1 W maximum, so ventilation in a sealed cabinet is manageable; just don't crowd it against other high-dissipation devices.","metaTitle":"Siemens 3VA1096-3ED32-0DA0 SENTRON MCCB, 16 A, 3-Pole, 75.6","metaDescription":"Siemens SENTRON 3VA1096-3ED32-0DA0 molded case circuit breaker, 16 A, 3-pole, 75.6 kA breaking capacity at 240 V. Active production. Sourced to order. RFQ for pricing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"75.6 kA","at 415 V":"52.5 kA","at 440 V":"32 kA","at 500 V":"7.5 kA","at 690 V":"7.5 kA","at 40 °C":"16 A","at 45 °C":"16 A","at 50 °C":"16 A","at 55 °C":"16 A","at 60 °C":"15 A","at 65 °C":"15 A","at 70 °C":"15 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"13.1 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA10963ED320AA0","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"500 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"N","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"nut keeper kit on both ends","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=178749&mlfb=3VA1096-3ED32-0DA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1096-3ED32-0DA0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA1096-3ED32-0DA0 at different voltages?","answer":"At 240 V it is 75.6 kA, at 415 V it is 52.5 kA, at 440 V it is 32 kA, and at 500 V and 690 V it is 7.5 kA. The 16 A frame derates as system voltage rises."},{"question":"Where can I buy 3VA1096-3ED32-0DA0 and how is it quoted?","answer":"We source this part to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote with lead time."},{"question":"Will 3VA1096-3ED32-0DA0 drop into a panel specified for 3VA1020-3ED36-0AA0?","answer":"Both are 3-pole SENTRON MCCBs in the same physical frame family, so the 70 mm depth, 76.2 mm width, and 130 mm height are identical. No rewiring or enclosure modification should be needed for the mechanical fit, but verify the current rating and trip curve match your circuit design."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1096-3ED32-0DA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1096-3ED32-0DA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}