{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1096-3ED32-0JH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1096-3ED32-0JH0","canonicalUrl":"https://aoctrl.com/siemens/3VA1096-3ED32-0JH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1096-3ED32-0JH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3VA1 IEC frame 100 circuit breaker, 3-pole, breaking capacity class N Icu=25kA @ 415V, line protection TM210, In=16A, with shunt trip STL 110-127V DC/AC, 2 auxiliary switches HQ, 1 trip alarm switch HQ, nut keeper kit.","salesMarkdown":"Overload protection is fixed at Ir=16 A, short-circuit protection set at Ii=10 x In (160 A), so it's a straight swap-in for a 16 A motor or distribution circuit without needing adjustment. The built-in shunt trip (STL) at 110-127 V DC/AC lets you drop the breaker remotely from a kiln control room or emergency-stop chain, and the two auxiliary switches plus one trip alarm switch (all HQ contacts) give the PLC a clean status signal — sealed against the grit, no contact chatter.","metaTitle":"Siemens 3VA1096-3ED32-0JH0 Circuit Breaker, 16A, 25kA @ 415V","metaDescription":"Siemens 3VA1096-3ED32-0JH0 IEC frame 100 circuit breaker, 3-pole, 16A, 25kA breaking capacity @ 415V. Active production. Sourced to order. Request RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=199834&mlfb=3VA1096-3ED32-0JH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1096-3ED32-0JH0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA1096-3ED32-0JH0?","answer":"Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels."},{"question":"What is 3VA1096-3ED32-0JH0's breaking capacity and protection settings?","answer":"It is a 3-pole IEC frame 100 breaker with breaking capacity class N: Icu=25 kA at 415 V. Overload protection is fixed at Ir=16 A, and short-circuit protection is fixed at Ii=10 x In (160 A)."},{"question":"What accessories are included with this circuit breaker?","answer":"It comes with a nut keeper kit, a shunt trip (STL) rated 110-127 V DC/AC 50/60 Hz, two auxiliary switches (HQ), and one trip alarm switch (HQ)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1096-3ED32-0JH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1096-3ED32-0JH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}