{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1102-6MG36-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1102-6MG36-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1102-6MG36-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1102-6MG36-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1102-6MG36-0AA0, molded case circuit breaker, 3-pole, 2 A rated continuous current, TM110M release, 220 kA at 240 V breaking capacity, 70 mm depth.","salesMarkdown":"## What this MCCB does on the line The TM110M thermal-magnetic release gives you an adjustable li max of 32 A, which lets you dial in the magnetic trip for motor inrush without nuisance trips on start-up. ## Breaking capacity — what voltage does to the numbers This MCCB's interrupting rating drops fast as voltage climbs: 220 kA at 240 V, 154 kA at 415 V, 76 kA at 440 V, and 7.5 kA at both 500 V and 690 V. That's typical for a compact frame — the arc energy scales with voltage, and the internal arc chute can only stretch so far. For a 480 V panel (common in North America), you're looking at somewhere between the 440 V and 500 V figures; treat it as 7.5 kA at 480 V unless the manufacturer publishes a specific number. ## Panel fit and physical integration The 3VA1102-6MG36-0AA0 measures 70 mm deep, 76.2 mm wide, and 130 mm tall. Depth of 70 mm leaves room for rear-access bus bars and cable lacing. The optional motor drive (product extension available) means you can remote-trip or auto-reset in an unattended location, but the base unit is manual-trip only. No communication function or phase failure detection on this version — it's a straight electromechanical breaker, not a smart meter.","metaTitle":"Siemens 3VA1102-6MG36-0AA0 SENTRON MCCB, 220 kA at 240 V","metaDescription":"Siemens SENTRON 3VA1102-6MG36-0AA0 molded case circuit breaker, 3-pole, 2 A rated, 220 kA breaking capacity at 240 V. Active production, sourced to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","title":"3VA1102-6MG36-0AA0","Height":"130 mm","at 240 V":"220 kA","at 415 V":"154 kA","at 440 V":"76 kA","at 500 V":"7.5 kA","at 690 V":"7.5 kA","at 40 °C":"2 A","at 45 °C":"2 A","at 50 °C":"2 A","at 55 °C":"2 A","at 60 °C":"2 A","at 65 °C":"2 A","at 70 °C":"2 A","Depth [in]":"2.8 in","Width [in]":"3 in","Height [in]":"5.1 in","description":"circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM110M, FM, In=2A without overload protection short-circuit protection Ii=15 x In clamp connection","Number of poles":"3","Product version":"Starter protection","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"1.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-40 °C","Other Measurement Function":"No","Rated continuous current Iu":"2 A","Rated insulation voltage Ui":"800 V","Ground fault monitoring version":"Without","Design of the overcurrent release":"TM110M","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Product extension / optional / motor drive":"Yes","Adjustable response value current / li max.":"32 A","Adjustable response value current / li min.":"32 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"I","Switching capacity class of the circuit breaker":"H","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (1.5 - 70 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/eaac75649c66bbf020d0a36b6068b720.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=802441&mlfb=3VA1102-6MG36-0AA0"},"ai":{"faq":[{"question":"Where can I buy 3VA1102-6MG36-0AA0 and what is the lead time?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time."},{"question":"What is the breaking capacity of 3VA1102-6MG36-0AA0 at different voltages?","answer":"220 kA at 240 V, 154 kA at 415 V, 76 kA at 440 V, and 7.5 kA at both 500 V and 690 V. The interrupting rating drops significantly above 440 V due to arc energy scaling."},{"question":"Will 3VA1102-6MG36-0AA0 drop into a panel specified for 3VA1110-5MH36-0AA0?","answer":"The 3VA1102-6MG36-0AA0 shares the same 3-pole SENTRON frame family, so the mounting footprint and depth are identical. It will drop into the same panel cutout without rewiring, provided the lower 2 A continuous rating and different TM110M release curve are acceptable for your motor branch circuit."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1102-6MG36-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1102-6MG36-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}